background image

Evaluation Board User Guide 

UG-077 

 

Rev. 0 | Page 13 of 16 

EVALUATION SOFTWARE MENU ITEMS 

08747-

029

 

Figure 24. Menu Bar 

MENU BAR 

File Menu 

The file menu has the following options: 

Load Setup 

Selecting 

Load Setup

 loads a previously saved AD9522 setup 

file (.stp). A setup file is a text file that contains the AD9522 
register setup file, plus any evaluation board settings. Note that 
you must still perform a VCO calibration. 

Save Setup 

Selecting 

Save Setup

 saves an AD9522 setup file (.stp). A setup 

file is a text file that contains the AD9522 register setup file, 
plus any evaluation board settings. 

Generate Binary File 

Select this menu option to generate binary setup files that can 
be used by EEPROM programmers. 

Exit 

Exits the evaluation software. No checking is performed to 
ensure that the existing setup is saved. 

I/O Menu 

The 

I/O

 menu includes the following options: 

Select Evaluation Board 

The AD9522 evaluation system allows one PC to control 
multiple evaluation boards. This window allows you to select 
which evaluation board the software is controlling. Click 

Refresh List

 to detect a recently connected evaluation board. 

08747-

022

 

Figure 25. USB Device Selection Window 

Configure Serial Port 

The 

I/O Interface

 window allows you to control how the USB 

controller interacts with the AD9522 serial port.  

08747-

023

 

Figure 26. I/O Interface Window 

If you are using I

2

C mode, this window allows you to select 

which address to use. Note that it should correspond to the S5 
and S6 jumper settings on the evaluation board. You can also 
click 

Detect Current Configuration

 to discover which I

2

address is active. 
However, if you are attempting to program an AD9522 on a 
remote board via a header cable from connector P1, then the 
I

2

C address of the on-board AD9522 must not match the I

2

address of the remote AD9522 that you are attempting to 
program.  

View Menu 

The 

View

 menu includes the following options: 

Debug Window 

This window allows you to write and read registers directly, as 
well as force the various configuration pins high and low. 

Options 

This window allows you to select Windows XP visual styles.  

Operational Modes Menu 

This menu allows you to select any of the three operational 
modes in the AD9522 data sheet.  

Help Menu 

Selecting 

Help

 opens the 

About AD9522

 window, which 

contains information such as revision number, region 
information, and contact information.

 

Содержание AD9522 Series

Страница 1: ...ttenuation Clock distribution GENERAL DESCRIPTION The AD9522 x hereafter referred to as AD9522 is a very low noise PLL clock synthesizer featuring an integrated VCO clock dividers and up to 24 outputs...

Страница 2: ...nfiguration Window Config PLL 8 REFMON STATUS and LD Buttons 9 Register W R Box 9 SYNC PD Power Down and RESET Buttons 9 EEPROM Control Window 9 Reference R Divider Window 9 Feedback N Divider Window...

Страница 3: ...ct that signal to the J13 SMA connector DC coupling is recommended in applications requiring automatic hitless reference switching There is a possibility that the AD9522 receive buffer can chatter whe...

Страница 4: ...w indicating that the evaluation board was found or red text appears indicating that the evaluation board was not found 2 If the evaluation board is found click anywhere in the pop up window with the...

Страница 5: ...MODE box found at the top of the main window see Figure 8 2 Enter the intended reference input frequency in megahertz in the REF 1 MHz box at the upper left corner of the main window 3 Click the tria...

Страница 6: ...modified 10 Set the VCO divider by clicking the green VCO box in the center of the main window immediately to the left of the Cal VCO button 11 Power down unused drivers by clicking the numbered tria...

Страница 7: ...Evaluation Board User Guide UG 077 Rev 0 Page 7 of 16 EVALUATION SOFTWARE COMPONENTS MAIN WINDOW 08747 008 Figure 8 AD9522 Evaluation Software Main Window...

Страница 8: ...Single Ended Mode check box Note that this mode should not be used simultaneously with Enable REF 1 or Enable REF 2 If Disable Switchover De Glitch is activated the AD9522 maintains the phase relation...

Страница 9: ...issue an I O update command whenever registers are written to the AD9522 SYNC PD POWER DOWN AND RESET BUTTONS The SYNC PD and RESET buttons allow you to control these pins on the AD9522 Each button ha...

Страница 10: ...r value For example it is not possible to use the internal VCO and a feedback divider of 30 However the R divider can be doubled which allows a feedback divider of 60 The feedback divider window has a...

Страница 11: ...ow shown in Figure 19 is accessed by clicking the Cal VCO button on the main window A valid reference input signal must be present to complete VCO calibration and the VCO must be recalibrated any time...

Страница 12: ...nation require ments and OUT9 through OUT11 have been terminated differently from OUT0 through OUT8 OUT0 through OUT8 are ac coupled and this termination scheme is ideal for LVDS drivers However this...

Страница 13: ...a recently connected evaluation board 08747 022 Figure 25 USB Device Selection Window Configure Serial Port The I O Interface window allows you to control how the USB controller interacts with the AD9...

Страница 14: ...hoice Typical phase detector frequencies for these applications are 10 MHz to 100 MHz and typical loop bandwidths for this loop filter are 50 kHz to 500 kHz depending on the configuration The user sho...

Страница 15: ...Configuration A dialog box appears and acknowledges the I2 C mode and address The evaluation software starts at I2 C Address 0x058 and stops at the first valid I2 C address that it finds If the targe...

Страница 16: ...set in the register setup stp file because the user normally initiates VCO calibration manually while running the evaluation software To avoid a checksum mismatch it is recommended that the user manu...

Отзывы: