manualshive.com logo in svg
background image

O p e r a t i o n / R e f e r e n c e   G u i d e

C o n t r o l   S y s t e m  A cc e s s o r i e s

UPC20+

Universal Power Controller

L a s t   Re v is e d :   09 / 1 2 / 20 0 7

Содержание UPC20 Plus

Страница 1: ...Operation Reference Guide Control System Accessories UPC20 Universal Power Controller Last Revised 09 12 2007...

Страница 2: ...liability applies whether damages are sought or a claim is made under this warranty or as a tort claim including negligence and strict product liability a contract claim or any other claim This limita...

Страница 3: ...le disconnect device shall be incorporated into the fixed wiring An insulated earthing conductor that is identical in size insulation material and thickness to be earthed and unearthed branch circuit...

Страница 4: ......

Страница 5: ...wer Control mode 5 Remote Sensor Control mode 5 Channel codes Remote Sensor mode 6 Installation 7 P1 Terminal Connections 7 P2 Terminal Connections 7 Control Mode 7 High Voltage Wiring Options 10 Sing...

Страница 6: ...ii UPC20 Universal Power Controller Table of Contents...

Страница 7: ...to protect the motor A timing adjustment potentiometer is user adjustable for automatic release of the relays The range is 0 to 90 seconds 1 2 and 3 button control modes are selectable In Power Contr...

Страница 8: ...E INSIDE COVER FOR DETAILED WIRING NOTE NO HIGH VOLTAGE THIS CONNECTION AND DIP SWITCH INFORMATION IN 4 8 CONTROL INPUT INPUTS GND 3 DATA 2 GND 4 4 3 IN 1 IN 2 5 6 IN 3 7 CONTACT 12 9 REMOTE C R IND C...

Страница 9: ...o theP1 Terminal Connections section on page 7 Set switch S1 to the line input voltage value used before applying power to the UPC20 High Voltage Terminal Block P1 High voltage input and output wiring...

Страница 10: ...0 seconds It is typically set to allow direction limit switches to operate or to reach the desired position Single Button Mode operates with one pushbutton in a sequence Up Stop Down Stop and so on fo...

Страница 11: ...his allows up to 8 UPC20 and IR sensors to be used in the same room without interfering with one another It is possible to control 2 separate UPC20 s with one handheld remote control The 4th switch of...

Страница 12: ...de Sw 1 Sw 2 Sw 3 Sw 4 Radio Code UPC20 Off Off Off Off 0 First On Off Off Off 1 First Off On Off Off 2 First On On Off Off 3 First Off Off On Off 4 First On Off On Off 5 First Off On On Off 6 First O...

Страница 13: ...is 20 Amps There are two 12 gauge jumpers that are wired to supply board power at 120 240 VAC and to connect the common terminals of the relays The jumpers are removed as needed according to the wiri...

Страница 14: ...d 2 off after time out Motor Momentary Off On Off On Minimum Push 1 load 1 on Release 1 load 1 off Push 2 load 2 on Release 2 load 2 off Maximum Push 1 load 1 on Release 1 load 1 off Note No delay on...

Страница 15: ...Push 2 again load 2 off Release 2 again load 2 still off Power Momentary 1 Latch ing 2 Minimum Push 1 load 1 on Release 1 load 1 still on Push 1 again load 1 off Release 1 again load 1 still off Push...

Страница 16: ...er Two Button On Off Off On Minimum Push 3 load 1 off Release 3 load 1 still off Push 4 load 2 off Release 4 load 2 off Maximum Push 3 load 1 off Release 3 load 1 still off Push 4 load 2 off Release 4...

Страница 17: ...circuit protected and the output supplies up to 25 mA for the remote sensor For dual circuit 277 VAC operation remove both 12 AWG wire jumpers FIG 6 Low voltage and 277 VAC high voltage wiring 1 2 3...

Страница 18: ...ts 4 Install conduit Provide conduit for high voltage low voltage and control wiring requirements using the 0 5 inch or 0 75 inch conduit connector knockouts 5 Connect high voltage wiring to the termi...

Страница 19: ...Installation 13 UPC20 Universal Power Controller...

Страница 20: ......

Страница 21: ...BELGIUM BRAZIL CANADA CHINA ENGLAND FRANCE GERMANY GREECE HONG KONG INDIA INDONESIA ITALY JAPAN LEBANON MALAYSIA MEXICO NETHERLANDS NEW ZEALAND PHILIPPINES PORTUGAL RUSSIA SINGAPORE SPAIN SWITZERLAND...

Отзывы: