UDM-0808-SIG Wiring and Connections
10
UDM-0808-SIG, UDM-RX02N and UDM-ABB-8-SIG Operation /Reference Guide
Serial Port - Default Communication Settings
Use hyper terminal with default serial settings to communicate with the UDM-0808-SIG (and UDM-RX02N):
DB9-to-RJ12 Adapter Cable Pinouts
The following table provides the pinout configuration for the DB9-to-RJ12
(FG-RS01, not included)
adapter
cable:
CASCADE Ports
The CASCADE ports allow UDM-0808-SIG Hubs to be chained together to increase the number of outputs
which can be delivered to the end points. The CASCADE IN and OUT connectors on the UDM Hubs require a
UDM-EXP-02 Cascade Cable (FG-1402-71 - not included).
The CASCADE (Out) ports can also be used to send audio to the UDM-ABB-8-SIG Signature Series Audio
Breakout Box (FG1402-60). Refer to the UDM-ABB-8-SIG Audio Breakout Box section on page 71 for
details.
Refer to the Cascading Hubs section on page 77 for details on configuring cascaded Hubs.
Default Serial Settings
Baud Rate:
115200
Data Bits:
8
Parity:
None
Stop Bits:
1
Flow Control:
None
DB9-to-RJ12 Adapter Cable Pinouts
DB9 connector
Function
Abbreviation
RJ12 connector
Pin 1
Not used
NC
Pin 2
Transmit Data
TD or TX or TXD
Pin 2
Pin 3
Receive Data
RD or RX or RXD
Pin 3
Pin 4
Data Set Ready
DSR
Pin 1
Pin 5
Signal Ground
GND
Pin 4, 5
Pin 6
Data Terminal Ready
DTR
Pin 6
Pin 7
Not Used
NC
Pin 8
Not Used
NC
Pin 9
Not Used
NC
FIG. 10
Cascade 5-8, 1-4 Ports
CASCADE 5-8 IN
CASCADE 5-8 OUT
CASCADE 1-4 IN
CASCADE 1-4 OUT
To another UDM Hub or
UDM-ABB-8-SIG (CASCADE IN port)
From source UDM Hub
(CASCADE OUT port)
From source UDM Hub
(CASCADE OUT port)
To another UDM Hub or
UDM-ABB-8-SIG (CASCADE IN port)
Содержание UDM-RX02N
Страница 22: ...UDM 0808 SIG Wiring and Connections 12 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 44: ...UDM 0808 SIG WebConsole 34 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 48: ...UDM 0808 SIG Firmware Upgrades 38 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 68: ...UDM RX02N NetLinx Programming 58 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 72: ...UDM RX02N Firmware Upgrades 62 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 76: ...UDM RX02N IR File Transfers 66 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 80: ...UDM RC05 Multi Format IR Remote Control 70 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 86: ...UDM ABB 8 SIG Audio Breakout Box 76 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...