background image

QUICK START GUIDE

MXD-1900L-PAN

 

19.4" Modero X

®

 Series Wall Mount Touch Panel

Overview

The MXD-1900L-PAN 19.4" Modero X Series

®

 Panoramic Wall Mount Touch Panel features a 

beautiful, panoramic capacitive multi-touch screen that provides users access to multiple 

applications with minimal navigation. It is hardware-ready for support of Near Field 

Communication™ (NFC) Technology to allow integration with NFC capable personal devices. 

The MXD-1900L-PAN is available in Portrait and Landscape layouts:     

Product Specifications 

Note: The MXD-1900L-PAN-P-NC (FG5968-22) and MXD-1900L-PAN-L-NC (FG5968-23) No 

Comm touch panels do not have camera, microphone, or NFC capability. These otherwise have 

all of the functionality of the MXD-1900L-PAN panels.

MXD-1900L-PAN Installation

• For more detailed installation instructions including important notes on thermal 

concerns with Rack and Wall installations, refer to the 

X-Series Touch Panels 

MXD/T-2000XL-PAN & MXD/T-1900L-PAN Instruction Manual.

 (available to view/

download from www.amx.com).

• Detailed specifications drawings for the MXD-1900L-PAN are available to download from 

www.amx.com.

The MXD-1900L-PAN may be installed directly into a solid surface environment, using either 

solid surface screws or the included locking tabs for different mounting options. Once 

installed, the MXD-1900L-PAN is contained within a clear outer housing known as the 

Backbox. The Backbox is removed to install it into a wall, or when using the optional Rough-In 

Box accessory(

FG039-15

).

Note: For typical mounting surfaces, such as drywall, use the locking tabs as the primary 

method for securing the Backbox to the surface. For thin walls or solid surfaces, use mounting 

screws (not included).

Installing the MXD-1900L-PAN Into a Wall

The MXD-1900L-PAN comes with a clear plastic Backbox (FIG. 2) designed to attach the panel 

to most standard wall materials. This Backbox has four locking tabs (2 on top, 2 on bottom) to 

help lock the Backbox to the wall. 

These locking tabs are only extended AFTER the Backbox is inserted into the wall.

• When installing the Backbox, make sure that the assembly is in the correct position and 

in the correct place. Once the locking tabs are extended and locked into place, removing 

the Backbox may be difficult without having access to the back of the wall or causing 

damage to the wall. 

• In order to ensure a stable installation of the MXD-1900L-PAN, the thickness of the wall 

material must be a minimum of .50 inches (1.27cm) and a maximum of .875 inches 

(2.22cm). The mounting surface should also be smooth and flat.

The Backbox also has four slots for accepting the temporary mounting posts mounted 

on the back of the device.  

Installing the Backbox

Since the cutout for the Backbox is off-center from the edges of the touch panel, use the 

included Installation Template (

68-5968-02

) to ensure proper placement. The template is 

marked on one side with directions for both landscape and portrait installations to ensure that 

the touch panel and Backbox are properly aligned.

WARNING: Using the Installation template to select the final placement of the Backbox is highly 

recommended. The outside edges of the template are the same dimensions as the touch panel, 

which allows you to troubleshoot possible conflicts with wall edges, doors, and other potential 

obstacles.

1.

Prepare the area by removing any screws or nails from the drywall before beginning the 

cutout process.

2.

After ensuring proper placement, cut out the mounting surface for the Backbox, using 

the (included) Installation Template as a guide.

CAUTION: Making sure that the actual cutout opening is slightly smaller than the provided 

dimensions is highly recommended. This provides a margin of error if the opening needs to 

be expanded. Too little wall material removed is always better than too much.

3.

Thread the incoming cables from their terminal locations through the surface opening 

(see FIG. 4 on reverse). 
Leave enough slack in the wiring to accommodate any re-positioning of the panel. 

 

Portrait

MXD-1900L-PAN-P

FG5968-06

Landscape

MXD-1900L-PAN-L

FG5968-12

FIG. 1  

MXD-1900L-PAN-P/L (PORTRAIT AND LANDSCAPE)

MXD-1900L-PAN SPECIFICATIONS

Dimensions (HWD)

• Landscape: 6 7/8" x 20 3/8" x 11/16" (175mm x 519mm x 19mm)

• Portrait: 20 3/8" x 6 7/8" x 11/16" (519mm x 175mm x 19mm)

Weight

7.0 lbs (3.18 Kg)

Power Consumption • Full-On: 35 W (

13.5V

, 2.6A)

• Standby: 7 W (

13.5V

, 0.52A)

External Power 

Supply Required 

Requires one of these AMX power sources (not included):

• PSR4.4 Power Supply, 4.5A, 3.5 mm Phoenix with Retention Screws 

(FG423-46)

• PSN4.4 Power Supply, 4.5A, 3.5 mm Phoenix, 

13.5V

 (

discontinued

(FG423-45)

• MXA-MPL Modero X Series Multi Preview Live (FG5968-10)

• MXA-MP Modero X Series Multi Preview (FG5968-20)

Certifications

• FCC Part 15 Class B

• C-Tick CISPR 22 Class B

• CE EN 55022 Class B and EN 55024

• CB Scheme IEC 60950-1

• IC

• IEC/EN-60950

• UL  60950-1

• RoHS/WEEE  compliant

Environmental

• Temperature (Operating): 32°F to 104°F (0°C to 40°C)

• Temperature (Storage): 4°F to 140°F (-20°C to 60°C)

• Humidity (Operating): 20% to 85% RH

• Humidity (Storage): 5% to 85% RH

• Power ("Heat") Dissipation:

On: 109.2 BTU/hr
Standby: 10.6 BTU/hr

Included 

Accessories

• Locking 2-pin Phoenix mate (41-0002-SA)

• MXA-USB-C, USB Port Cover Kit (FG5968-18)

• MXA-CLK, Modero X Series Cleaning Kit (FG5968-16)

• Installation Template 19.4” (68-5968-02)

Sleep Button

NFC Sensor

Sleep

NFC

Button

Sensor

MXD-1900L-PAN-P

MXD-1900L-PAN-L

FIG. 2  

MXD-1900L-PAN BACKBOX

FIG. 3  

MXD-1900L-PAN (LANDSCAPE)

FIG. 4  

MXD-1900L-PAN BACKBOX INSTALLATION (LANDSCAPE)

Locking Tabs

Locking Tabs

Temporary Mounting Posts

Temporary Mounting Posts

Backbox

Backbox knockouts (X8)

Locking tabs (X4)

Mounting screws

placement (optional)

Wall

8X Knock Outs

Remove For Cable

Routing As Needed

4X Installation Clamp

For Wall Thickness

.37 [12.01] to .98 [25.01]

Cables routed to 

wall opening

Отзывы: