background image

QUICK START GUIDE

ICSLan Device Control Boxes

Overview

The EXB family of ICSLan Device Control Boxes provides Ethernet-based remote port 

expansion for NetLinx Central Controllers which can provide remote ports for a master 

(eliminating the need to implement another Central Controller), or to provide large numbers of 

ports in a rack-mount environment. 

Common Features

Many features are common to all products in the EXB family, as described in the following 

table. Module-specific connector descriptions are in the following section. For additional 

details on the individual modules, refer to the 

EXB Ethernet Modules Operation/Reference Guide

 

(available online at www.amx.com).

SAFETY INSTRUCTIONS

• For UL compliance, the EXB family of ICSLan Device Control Boxes should be powered 

directly via any listed external IEC/UL 60950-1 2nd edition certified LPS PoE switch or 

injector, such as the AMX NXA-ENET8POE or PS-POE-AF.

• The EXB family of ICSLan Device Control Boxes are intended for Network Environment 0 

per IEC TR62101, and are to be connected only to PoE networks without routing to the 

outside plant.

Connections and Wiring

LAN/PoE Port

The LAN/PoE (RJ45) port on all EXB Modules provides 10/100 BaseT network connectivity. 

Use standard Cat5/6/6E ethernet cable to connect the EXB Module to the LAN. The following 

table lists the pinouts, signals, and pairing for the Network port. 

  

 

The Ethernet Port LEDs show communication activity, connection status, speeds, and mode 

information:

SPD (speed)

 - Yellow LED lights On when the connection speed is 100 Mbps and turns 

Off when the speed is 10 Mbps.

L/A (link/activity)

 - Green LED lights On when the Ethernet cables are connected and 

terminated correctly, and blinks when receiving Ethernet data packets.

Module-Specific Connectors

EXB-COM2

Port 1(Multi-Protocol COM Port)

Port 1 (multi-protocol port) is a 10-pin 3.5mm captive-wire connector that supports RS-232/

422/485 serial communication. The following table provides the pinout configuration:  

Port 2 (RS-232 only)

Port 2 is a 5-pin 3.5mm captive-wire connector that supports RS-232 (only) serial 

communication. Pins 1-5 on COM2 provide the same RS-232 functions as pins 1-5 on the 

COM1 connector: 

EXB-I/O8

Port 1 (I/O 1-8)

Port 1 is a 10-pin 3.5mm captive-wire connector that provides eight I/O contacts (1-8) as well 

as PWR and GND. 

• When used for voltage inputs, the I/O port detects a low signal (0 - 1.5 VDC) as a Push, 

and a high signal (3.3 - 5 VDC) as a Release.

• Although a high signal is defined as 3.3 - 5 VDC, this port can handle up to 12V without 

harm.

• When used for outputs, the I/O port acts as a switch to GND and is rated for 200mA @ 

12 VDC.

Note: The I/Os on this Module are not dry closure; they are electronic switches that float at 3V 

when Off. Therefore, they should not be expected to work in situations that require true dry 

contact (or dry closure). The I/Os do work with AMX PC1, PC2, UPC20 and UPC20+.

EXB ETHERNET MODULES - PRODUCT FAMILY

Name

FG#

Description

EXB-COM2

FG2100-22

ICSLan Serial Interface, 2 Ports

EXB-I/O8

FG2100-21

ICSLan Input/Output Interface, 8 Channels

EXB-IRS4

FG2100-23

ICSLan IR/S Interface, 4 IR/S and 4 Inputs

EXB-MP1

FG2100-26

ICSLan Multi-Port, 1 COM, 1 IR/S, 2 I/O, 1 IR RX

EXB-REL8

FG2100-20

ICSLan Relay Interface, 8 Channels

EXB MODULES - COMMON FEATURES

Dimensions (HWD):

• EXB-COM2, -I/O8, -IRS4 and -REL8:

1.00” x 4.35” x 5.15” (25.48 x 110.36 x 130.81)

• EXB-MP1:

1.00” x 3.04” x 4.82” (25.48cm x 77.14cm x 122.43cm)

Weight:

• EXB-COM2: 1 lb (454 g)

• EXB-I/O8: 1 lb (454 g)

• EXB-IRS4: 1 lb (454 g)

• EXB-MP1: 0.75 lb (280 g)

• EXB-REL8: 1 lb (454 g)

Power Requirements:

PoE (Power-over-Ethernet).
Idle (minimum) Power Draw:

Busy (maximum) Power Draw

EXB-COM2:

40mA 1.92 watts

40mA 1.92 watts

EXB-IO8:

30mA 1.44 watts

40mA 1.92 watts

EXB-IRS4:

40mA 1.92 watts

50mA 2.4 watts

EXB-MP1

40mA 1.92 watts

40mA 1.92 watts

EXB-REL8:

40mA 1.92 watts

70mA 3.36 watts

Enclosure:

Metal with black matte finish

Front Panel Components

ID Pushbutton:

The ID Pushbutton serves four functions:

ID Mode

: Used in conjunction with the ID Mode feature in NetLinx Studio, 

a momentary push assigns a device address to the Module. See the 

U

sing ID Mode to Set the Device Address on the EXB Modules 

section in 

the Instruction Manual for details.

Static/DHCP

: If the button is pressed and held for 10 seconds or longer 

and then released, the unit toggles between static and dynamic IP 

addressing. See the 

Toggling Between Static and DHCP IP Addressing 

section in the Instruction Manual  for details.

Factory Reset:

 If the ID button is held for 10 seconds or longer during 

the boot process, the unit will reset to factory defaults. See the 

Performing a Factory Reset 

section in the Instruction Manual for details.

Factory Image

: If the ID pushbutton is held for 20 seconds and released 

while the Module is booting up, the Module will restore itself to a factory 

firmware image. See the 

Resetting the Unit to the Factory Default 

Firmware Image

 section in the Instruction Manual for details.

Status LED:

The green Status LED indicates unit status. 

See the 

Detailed LED Behavior

 section in the Instruction Manual for details.

L/A LED:

The green L/A (Link / Active) LED indicates communication status. 

See the 

Detailed LED Behavior

 section in the Instruction Manual for details.

Rear Panel Components

Ethernet / PoE 

Connector

RJ-45 connector provides IP communication and PoE. 

This is an Auto MDI/MDI-X enabled port, therefore either straight-through 

or crossover Ethernet cables can be used.

Note: The Ethernet connector is located on the front panel of the 

EXB-MP1.

Storage/Operating 

Environment:

• Operating Temperature: 0° C (32° F) to 40° C (104° F)

• Storage Temperature: -10° C (14° F) to 60° C (140° F)

• Operating Humidity: 5% to 85% RH (non-condensing)

• Heat Dissipation (Typical): 36.9 BTU/hr

• Designed for indoor use only.

Certifications:

FCC Part 15 Class B, CE, and IEC 60950

Included Accessories: Phoenix (captive-wire) connectors - varies as required by model. See the 

Operation/Reference Guide 

for details.

Other AMX Equipment • NXA-ENET8POE Gigabit Ethernet Switch (FG2178-62)

• PS-POE-AF PoE Injector (FG423-80)

• AVB-VSTYLE-SURFACE-MNT V-Style Module Surface Mount 

(FG1010-722)

• AVB-VSTYLE-RMK-1U V-Style Module Tray (FG1010-720)

• AVB-VSTYLE-RMK-FILL-1U V-Style Module Tray w/ fill plates 

(FG1010-721)

• AVB-VSTYLE-POLE-MNT V Style Module Pole Mount (FG1010-723)

LAN/POE PORT PINOUTS AND SIGNALS

Pin

Signals

Connections

Pairing

Color

1

TX +

1 --------- 1

1 --------- 2

White-Orange

2

TX -

2 --------- 2

Orange

3

RX +

3 --------- 3

3 --------- 6

White-Green

4

DC +

4 --------- 4

Blue

5

DC +

5 --------- 5

White-Blue

6

RX -

6 --------- 6

Green

7

DC -

7 --------- 7

White-Brown

8

DC -

8 --------- 8

Brown

EXB-COM2 COM 1 PORT PINOUTS

Wiring Configuration

Signal

Function

RS-232

RS-422

RS-485

GND

Signal ground

X

X

RXD

Receive data

X

TXD

Transmit data

X

CTS

Clear to send

X

RTS

Request to send

X

TX+

Transmit data

X

X    

(strap to pin 8)

TX-

Transmit data

X

X    

(strap to pin 9)

RX+

Receive data

X

X    

(strap to pin 6)

RX-

Receive data

X

X    

(strap to pin 7)

+12 VDC

Power

optional optional

EXB-COM2 PORT 2 PIN ASSIGNMENTS

Signal

Function

Signal

Function

GND

 Signal ground

CTS

 Clear to send

RXD

 Receive data

RTS

 Request to send

TXD

 Transmit data

EXB-I/O8 I/O8 CONNECTOR PIN ASSIGNMENTS

Signal Function

+12V

+12VDC (max current 200 mA)

8 -1

Channels 8 - 1

GND

Ground