Amtech ADAPT System Скачать руководство пользователя страница 2

PREFACE 

THANK YOU for purchasing the “ADAPT SYSTEM”. 

“ADAPT  SYSTEM”  offers  you  the  ultimate  solution  in  Sucker  Rod  Control.  It  is  a  smart  system 
that integrates a Variable Frequency Drive and an SRP controller. 

PLEASE  READ  THIS  MANUAL  THOROUGHLY

  before  use,  and  keep  the  manual  at  hand  for 

later reference. 

 

WARNING 

 

ALWAYS READ THIS MANUAL THOROUGHLY BEFORE USING THE ADAPT SYSTEM.

  

THIS SYSTEM CONTAINS HIGH VOLTAGE CIRCUITS THAT MAY BE FATAL 
TO HUMANS. USE EXTREME CAUTION DURING INSTALLATION. 
MAINTENANCE MUST BE PERFORMED BY QUALIFIED TECHNICIANS, AND 
ALL POWER SOURCES MUST BE DISCONNECTED BEFORE ANY 
MAINTENANCE. SUFFICIENT NOTICE MUST BE GIVEN TO THE GENERAL 
OPERATORS AND WORKERS BEFORE STARTING. 

• 

ELECTRIC SHOCK MAY OCCUR IF THE FOLLOWING POINTS ARE NOT OBSERVED

(1) DO NOT OPEN THE FRONT COVER WHILE THE POWER IS ON. 

(2) ALWAYS GROUND THE UNIT CASE. THE GROUNDING METHOD MUST COMPLY WITH 
THE LAWS OF THE COUNTRY WHERE THE UNIT IS BEING INSTALLED 

• THE UNIT MAY BE DESTROYED BEYOND REPAIR IF THE FOLLOWING POINTS ARE NOT 

OBSERVED. 

(1) OPERATION WITHIN THE UNIT SPECIFICATIONS. 

(2) PROPER CABLE CONNECTIONS TO INPUT/OUTPUT TERMINALS. 

(3) CLEANING AND ENOUGH VENTILATION TO THE UNIT INTAKE/OUTTAKE PORTS. 

(4) OBSERVATION OF CAUTIONS LISTED IN THIS INSTRUCTION MANUAL. 

• THERE MAY BE SOURCES OF NOISE AROUND THIS UNIT AND MOTOR DRIVEN BY THIS 
UNIT.  CONSIDER  THE  POWER  SUPPLY  SYSTEM,  INSTALLATION  PLACE  AND  WIRING 
METHOD BEFORE INSTALLATION 

INSTALL  THE  UNIT  AWAY  FROM  DEVICES  THAT  HANDLE  MINUTE  SIGNALS,  SUCH  AS 
MEDICAL  EQUIPMENT  IN  PARTICULAR.  ALSO  SEPARATE  THE  DEVICES  ELECTRICALLY, 
AND TAKE SUFFICIENT NOISE MEASURES. 

•TAKE  SUFFICIENT  SAFETY  MEASURES  WHEN  USING  THIS  UNIT  FOR  PASSENGER 
TRANSPORTATION, SUCH AS IN LIFTS (ELEVATORS). 
 

Содержание ADAPT System

Страница 1: ...75kW Start up Guide ADAPT System AMTECH NOTICE 1 Read this guide thoroughly before using the ADAPT System and store in a safe place for reference 2 Make sure that this manual is delivered to the final...

Страница 2: ...OBSERVED 1 DO NOT OPEN THE FRONT COVER WHILE THE POWER IS ON 2 ALWAYS GROUND THE UNIT CASE THE GROUNDING METHOD MUST COMPLY WITH THE LAWS OF THE COUNTRY WHERE THE UNIT IS BEING INSTALLED THE UNIT MAY...

Страница 3: ...uries or physical damage Note that some items described as CAUTION may lead to major problems depending on the situation In any case important information that must be observed is described A qualifie...

Страница 4: ...eck both keys for Panel HMI door Check whether any damage is there or not Refer the drawing check each item panel with Bill of material attached with drawing Mount the panel at sufficient height Take...

Страница 5: ...utput terminal to motor i e R Y and B Now switch off the MCB Switch ON the mains supply Switch ON the mains MCCB for 2 second OFF again to verify the supply to the drive If drive is started stopped he...

Страница 6: ...de Set the C 03 0 1 i e select PSI 1 for Forward run Set the C 13 0 11 i e Motor Torque current Analog output to the PLC for current feedback Auto Tuning Decouple the Motor from the load Put Drive in...

Страница 7: ...ent is 43 A then Drive will give 2 5 V PLC will read 255 count PLC current analog input count x Motor rated current 512 para 23 43 255 x 87 512 To check the torque current of the drive See the paramet...

Страница 8: ...3852 Oakcliff Industrial Court Doraville GA 30340 Phone 770 469 5240 Fax 678 894 4043 E mail info amtechdrives com URL www amtechdrives com Contact Us Rep Distributor Address...