AMT MSV1 Series Скачать руководство пользователя страница 1

Specifications Information and Repair Parts Manual  

     

MSV1, MSV3 and MSV5 Series

                                                           

5910-251-00

1

10/2016

Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate 

or maintain the product described. Protect yourself and others by observing all safety information. The Safety Instructions are contained in the General Operating 

Instructions. Failure to comply with the safety instructions accompanying this product could result in personal injury and/or property damage! Retain instructions 

f

or future reference.  AMT reserves the right to discontinue any model or change specifications at any time without incurring any obligation.

©2016 AMT Pump Company, A Subsidiary of The Gorman-Rupp Company, All Rights Reserved.

Periodic maintenance and inspection is required on all pumps to insure proper operation. Unit must be clear of debris and sediment. Inspect for leaks and loose bolts. Failure to do so 

voids warranty.

Multistage Centrifugal Pumps

Vertical Inline Models

Refer to pump manual 1808-634-00 for General Operating and Safety Instructions.

 

All units are for use with non-flammable, non-abrasive liquids compatible 
with pump component materials.

IMPORTANT: Not for use with petroleum based liquids.

 

INSTALLATION

MOUNTING

Preferred mounting position is with motor shaft aligned vertically.
(See Figure 1)
1.  Choose a solid, level surface with adequate support such as a concrete 

slab floor.

2.  Use a level against pump to check for plumb. For uneven surfaces, shim 

beneath feet of Casing (Ref. No. 38) to attain proper alignment.

3.  Securely fasten Casing to mount surface at all four mount holes to avoid 

tip-over of pump. If space limitations dictate, pump may also be mounted 
horizontally if adequate support is provided. Do NOT mount motor end 
down or with shaft centerline below horizontal plane.

PIPING

Pump may have a protective cover over inlet and outlet for shipping purposes. 

If present, be sure to remove these covers prior to attaching piping. If flange 

Screws (Ref. No. 41) are loosened, be sure to re-tighten evenly and torque to 
33 ft-lbs [45 N-m] to avoid Gasket (Ref. No. 39) failure.

Starving the pump of liquid could cause low performance and damage to pump 
and seal. To avoid this, use suction piping that is short and either matches 
pump port diameter or is larger, do not reduce. Also, immediately preceding 
pump inlet, provide a section of straight pipe equal in length to a minimum 4 
diameters of pipe size and avoid using valves.

These pumps develop very high pressures. Be sure to confirm that pressure 
rating of all piping and fittings is adequately sized before use. Rating must be 
sufficiently larger than the combination of both inlet pressure plus the maximum 

pressure pump can develop.

DESCRIPTION

APPLICATIONS

These commercial/industrial centrifugal pumps are non-self-priming (gravity feed) units designed to handle high-pressure/low-flow liquid transfer applications 

where no suction lift is required. Typical installations include hot and chilled water, boiler feed, condensate return, irrigation, high pressure wash-down, booster 
service, and sprinkler systems. These pumps have NOT been investigated for use in potable (drinking) water systems.

FEATURES

The in-line port design and compact footprint of these pumps allows for a clean installation. All models feature a shaft seal that can be replaced easily without the 

need to disassemble the entire pump. An optional ANSI/ASME flange kit is available. Pumps are equipped with high efficiency closed impellers, and have a cas

-

ing working pressure to 536 ft./232 psi [1600 kPa]. Handle liquid temperatures from 40° F to 180° F [4° to 82° C]. For use with clear, nonabrasive, nonflammable 

liquids compatible with pump component materials. 

MOTOR

All models have 3450 RPM (2850 RPM for 50 Hz) continuous duty TEFC motors. Single phase units are capacitor start and have automatic reset thermal protec-

tion. All models are manual mode and require field wiring, no controls are supplied.

 

Motors have multi-voltage options. To avoid damage to motor, be sure to arrange internal motor wiring to match electric supply voltage before applying power 

(see motor nameplate for specific wiring diagram).

PUMP CONSTRUCTION

Pump construction is cast iron casing and adapter; 304 stainless steel impellers, chambers and column; Teflon® wear rings; 304L stainless steel pump shaft 

with tungsten carbide sleeve bearings; EPDM o-rings and gaskets; a mechanical shaft seal of stainless steel, carbon graphite, and tungsten carbide wear faces.

Figure 1 - Mounting

Содержание MSV1 Series

Страница 1: ...ng the pump of liquid could cause low performance and damage to pump and seal To avoid this use suction piping that is short and either matches pump port diameter or is larger do not reduce Also immediately preceding pump inlet provide a section of straight pipe equal in length to a minimum 4 diameters of pipe size and avoid using valves These pumps develop very high pressures Be sure to confirm t...

Страница 2: ... valve if present NOTE Make sure bypass valve is closed 2 Permit liquid to flow into pump thru suction port by gravity 3 Allow air to escape from pump by cracking open Vent Plug Ref No 13 in top of pump housing near motor 4 Wait for liquid to cease sputtering When liquid flow changes to a steady stream with no air close Vent Plug 5 Run pump briefly then repeat steps 1 thru 4 repeatedly until all a...

Страница 3: ...ge to new seal 1 Once shaft is free of burrs lubricate Shaft and o ring cavity in Adapter Ref No 8 with soapy water 2 Carefully slide new Shaft Seal Assembly onto Shaft then tighten in clockwise direction and torque to 26 ft lbs 35 N m 3 Mark or otherwise note shaft height Lift shaft as high as it will go then lower it back down the total distance Maintain this position while evenly tightening 3 s...

Страница 4: ...1 loose 15 Use a putty knife to scrape off old Gasket Ref No 40 from Flange and Casing REASSEMBLY 1 Always use new Gaskets Ref No 40 when reassembling Attach pipe Flanges Ref No 41 with Fasteners Ref No 42 Tighten evenly and torque to 33 ft lbs 45 N m 2 Place new O ring Ref No 19 into cleaned groove of Casing Ref No 39 be sure to lubricate with soapy water or suitable material 3 Place stage 1 Volu...

Страница 5: ... inlet conditions Turn pump off purge the air from the pump via the vent plug NOTE May take multiple attempts to vent all air from the pump Make sure the bypass valve is closed and installed correctly 5 Strainers check valves or foot valves are clogged 5 Remove strainer screen or valve and inspect Clean and replace 6 Incorrect drain plug installed 6 If the proper drain plug that was supplied with ...

Страница 6: ...Specifications Information and Repair Parts Manual MSV1 MSV3 and MSV5 Series 5910 251 00 6 10 2016 Multistage Centrifugal Pumps Figure 5 Assembly Map 1 3 Series ...

Страница 7: ...Specifications Information and Repair Parts Manual MSV1 MSV3 and MSV5 Series 5910 251 00 7 10 2016 Multistage Centrifugal Pumps Figure 6 Assembly Map 5 Series ...

Страница 8: ...Series 5910 251 00 8 10 2016 For Repair Parts contact dealer where pump was purchased Please provide following information Model Number Serial Number if any Part description and number as shown in parts list Figure 7 Repair Parts Illustrations Multistage Centrifugal Pumps ...

Страница 9: ...els Only 5900 170 00 5900 170 00 N A 1 25 Sleeve 18 0mm 2 Stage Models Only 5900 094 00 5900 094 00 N A 1 26 Impeller Weldment 5900 010 00 5920 010 00 5930 010 00 Varies 27 Sleeve 17 5 26 0mm Standard 5900 080 00 5900 080 00 5930 090 00 Varies 28 Cap Incl w Ref 30 Incl w Ref 30 Incl w Ref 30 Varies 29 Wear Ring Teflon Incl w Ref 30 Incl w Ref 30 Incl w Ref 30 Varies 30 Crossover Weldment Includes ...

Страница 10: ... 5900 038 00 3 8 16UNC 1 5900 725 00 5900 623 00 5900 523 00 25 Stage 3 1626 325 00 1626 331 00 5900 070 90 5900 030 00 5900 038 00 3 8 16UNC 1 5900 725 00 5900 625 00 5900 525 00 27 Stage 3 1626 325 00 1626 331 00 5900 070 90 5900 030 00 5900 038 00 3 8 16UNC 1 5900 727 00 5900 627 00 5900 527 00 3 Series 2 Stage 1 1626 322 00 1626 328 00 5900 070 90 5900 030 00 5900 038 00 3 8 16UNC 1 5900 702 0...

Страница 11: ...00 3 8 16UNC 1 5900 715 00 5900 615 00 5930 510 00 11 Stage 5 N A 1626 360 00 5920 070 90 5920 030 00 5920 038 00 1 2 13UNC 1 5930 711 00 5930 611 00 5930 511 00 12 Stage 5 N A 1626 360 00 5920 070 90 5920 030 00 5920 038 00 1 2 13UNC 1 5930 712 00 5930 612 00 5930 512 00 13 Stage 5 N A 1626 360 00 5920 070 90 5920 030 00 5920 038 00 1 2 13UNC 1 5930 713 00 5930 613 00 5930 513 00 14 Stage 5 N A 1...

Страница 12: ...Specifications Information and Repair Parts Manual MSV1 MSV3 and MSV5 Series 5910 251 00 12 10 2016 Figure 8 Replacement Shaft Seal ...

Страница 13: ...Specifications Information and Repair Parts Manual MSV1 MSV3 and MSV5 Series 5910 251 00 13 10 2016 NOTES ...

Страница 14: ...Specifications Information and Repair Parts Manual MSV1 MSV3 and MSV5 Series 5910 251 00 14 10 2016 NOTES ...

Страница 15: ......

Страница 16: ...www amtpump com ...

Отзывы: