Please  read  and  save  this  Repair  Parts  Manual.  Read  this  manual  and  the  General  Operating  Instructions  carefully  before  attempting  to  assemble, 
install, operate or maintain the product described. Protect yourself and others by observing all safety information. The Safety Instructions are contained 
in  the  General  Operating  Instructions.  Failure  to  comply  with  the  safety  instructions  accompanying  this  product  could  result  in  personal  injury  and/or 
property damage! Retain instructions for future reference

.  

AMT reserves the right to discontinue any model or change specifications at any time without 

incurring any obligation.

 

©2015 AMT Pump Company, A Subsidiary of The Gorman-Rupp Company, All Rights Reserved.

 

 
Periodic maintenance and inspection is required on all pumps to ensure proper operation. Unit must be clear of debris and sediment. Inspect for leaks and loose bolts. Failure 
to do so voids warranty. 

 

Stainless Steel Rotary Drum Pump 

  

DESCRIPTION 

This  stainless  steel  rotary  drum  pump  can  dispense  and  transfer  aggressive  chemicals  such  as  esters,  ketones,  alcohols,  bases,  hydrocarbons  and 
chlorinated  hydrocarbons  which  are  compatible  with  pump  component  materials*.  This  self-priming  pump  is  used  for  pumping  applications  on  farms, 
construction sites, manufacturing plants and laboratories. 
 
(*) Always refer to a chemical resistance chart to confirm compatibility. Not rated for food products. 
 

 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

SPECIFICATIONS 

Flow………………………………………………..…7.5 GPM @ 135 RPM 
Maximum Liquid Temperature………………………………...200̊ F (93̊C) 
Mounting……………………………………………………2” Bung Adapter 
Inlet………………………………………………………………….…1” NPT 
Outlet………………………………………………........................3/4” NPT 

 
UNPACKING 

 
When unpacking the unit, inspect carefully for any damage that may 
have occurred during transit. 
 
Check for loose, missing, or damaged parts. Transit damage claims 
should be made to the shipping company. 

 
GENERAL SAFTEY INFORMATION 

 

 

It  is  the  responsibility  of  the  user  to  operate  the  pump  in 
conformance  with  OSHA  rules  for  dispensing  liquids.  Pump 
containers  should  be  grounded  when  using  with  flammable 
liquids  to  avoid  static  electricity.  Pump  should  be  washed  out 
before  usage  since  processing  lubricants  could  contaminate  the 
fluid. 

 

1. 

When  using  a  hand  pump  (especially  when  pumping 
flammable,  combustible  or  hazardous  liquids)  follow  all 
electrical  and  safety  codes,  as  well  as  the  United  States 
Occupational  Safety  and  Health  Act  (OSHA),  most  recent 
National  Electrical  Code  (NEC),  National  Fire  Protection 
Association,  Inc.*  (NFPA)  Code  30  (Flammable  and 
Combustible  Code),  NFPA  56A  (Standard  for  use  of 
Inhalation  Anesthetics),  NFPA  77  (Static  Electricity),  NFPA 
78  (Lighting  Protection  Code),  NFPA  80  (Standard  for  Fire 
Doors  and  Windows),  NFPA  251  (Standard  Method  of  Fire 
Test  of  Building  Construction),  NFPA  704  (Identification  of 
the  Fire  Hazards  of  Materials),  other  NFPA  codes,  local 
codes and ordinances, as needed in a particular application. 

 

 

(*)Any  of  the  NFPA  Codes  can  be  obtained  from:  National 
Fire  Protection  Association,  Inc.,  1  Batterymarch  Park, 
Quincy, MA 02269, telephone 1-800-344-3555. Write or call 
for listing and prices. 

 

2. 

Know  the  pump  application,  limitations,  and  potential 
hazards.  The  WARNING  statements  indicate  potentially 
hazardous  conditions  for  the  operator  or  equipment.  TAKE 
NECESSARY  STEPS  TO  PROTECT  PERSONNEL  AND 
EQUIPMENT.  

 

Pump should only be used with liquids compatible with pump 
component 

materials. 

Consult 

PUMP 

CHEMICAL 

COMPATIBILITY  CHART  and  PUMP  SPECIFICATIONS. 
Also,  the  chemical  supplier  should  be  consulted  regarding 

any questions of chemical compatibility, proper and safe use 
and  handling  of  chemical.  Misapplication  of  pump  or  use  of 
incompatible liquids will void warranty.  

 

In order to properly use this product familiarize yourself with this 
pump and also with the liquid (chemical, etc.) that is going to be 
pumped through the unit. Although this pump is suitable for 
many liquids, it is not suitable for all liquids or liquids with debris 
or solids! 
 
 
 

3. 

Pumping  hazardous,  flammable,  or  combustible  liquids 
should only be done in buildings, rooms, or areas suited for 
this  purpose.  (See  NFPA  30,  NFPA  78,  NFPA  80,  NFPA 
251,  NFPA  704,  other  suitable  NFPA  codes,  OSHA, 
insurance companies, local codes and ordinances.) 

 

When  filling  cans,  drums,  etc.  with  combustible  or  flammable  liquids, 
both  containers  (container  pumping  from  and  container  pumping  to), 
should  be  bonded  and  grounded  to  dissipate  possible  accumulations 
of  static  electricity  and  minimize  sparks  caused  by  static  electricity. 
(Refer to NFPA 77 for specifics and further details.) Removal of outer 
garments  in  work  areas  where  there  may  be  flammable  or  explosive 
liquids,  which  are  ignitable  with  low  electrical  energy  can  be  fatal 
and/or cause property damage. (Refer to NFPA 56A and NFPA 77 for 
further details.) 

4. 

The WARNING  and  instructions  that  follow  pertain  not  only 
to gasoline, but to any flammable, combustible or hazardous 
fluid. 

 

Gasoline  is  a  highly  flammable  fuel.  The  improper  use,  handling,  or 
storage of gasoline can be dangerous. Prevent accidents by following 
these safety rules. 

a. 

Use gasoline only as fuel, never as a cleaning fluid.

 

b. 

Use  only  an  approved  container  to  hold  or  store  gasoline. 
Never  store  gasoline  in  familiar  containers  such  as  milk 
containers or soda pop bottles.

 

c. 

Store gasoline in a cool location, out of the reach of children. 
Never store gasoline near heat or an open flame.

 

d. 

Provide  a  fire  extinguisher  nearby  when  working  with 
gasoline.  Be  sure  extinguisher  is  in  operating  condition 

– 

check  the  pressure  gauge  of  indicator.  Be  familiar  with  its 
proper use. Consult local fire department for the correct type 
of extinguisher for your application. Extinguishers rated ABC 
by  the  National  Fire  Protection  Association  are  appropriate 
for most applications. 

e. 

Provide  positive  shut-off  valves  on  all  permanent  fuel 
supplies.  Fuel  lines  must  be  of  steel  piping,  adequately 
secured and free from leaks.

 

f. 

Provide  adequate  ventilation  and  clean  up  any  spills  when 

Содержание 5271-98

Страница 1: ...plication Any of the NFPA Codes can be obtained from National Fire Protection Association Inc 1 Batterymarch Park Quincy MA 02269 telephone 1 800 344 3555 Write or call for listing and prices 2 Know the pump application limitations and potential hazards The WARNING statements indicate potentially hazardous conditions for the operator or equipment TAKE NECESSARY STEPS TO PROTECT PERSONNEL AND EQUIP...

Страница 2: ...ake workshop childproof with padlocks master switches and by removing starter keys Failure to follow all General Safety Information can result in a fatality personal injury and or property damage ASSEMBLY AND INSTALLATION 1 Screw bung adapter Ref No 12 into drum with threaded end down 2 Screw spout Ref No 1 into casing Ref No 3 Use Teflon sealant tape provided Do not over tighten 3 Screw suction t...

Страница 3: ...by grasping covers and sliding towards 3 o clock position Do not use excessive force Hold in position and re tighten cover bolts 10 Damaged worn pump parts 10 Remove pump cover and inspect for broken pieces Components should have smooth finish no large grooves or voids Replace damaged parts Piston type pumps may include a poppet valve which is designed to prevent back flow If excessive leakage pas...

Страница 4: ... and Repair Parts Manual 5271 98 x For Repair Parts contact dealer where pump was purchased Please provide following information Model Number Serial Number if any Part description and number as shown in parts list Figure 1 Repair Parts Illustration ...

Страница 5: ...ludes Ref Nos 5 6 and 7 9 Lip Seal 5271 300 00 1 10 Front Cover 5271 020 90 1 includes Ref No 11 11 Cap Screw Incl w Ref 2 9 and 12 12 Handle Kit 5271 100 90 1 includes Ref Nos 11 12 13 18 and 19 13 Handle Incl w Ref 12 1 14 Gasket Kit 5271 301 90 2 15 Cover Gasket Washer Kit 5271 302 90 2 includes Ref Nos 15 and 16 16 Washer Incl w Ref 15 2 17 Bung Adapter Assembly 5271 171 90 1 18 Handle Shaft I...

Страница 6: ...Specifications Information and Repair Parts Manual NOTES ...

Страница 7: ......

Страница 8: ...www amtpump com ...

Отзывы: