AMT 4895 Скачать руководство пользователя страница 1

Specifications Information and Repair Parts Manual  

     

489 & 490 Series

                                                           

4890-251-00

1

9/2016

Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate 

or maintain the product described. Protect yourself and others by observing all safety information. The Safety Instructions are contained in the General Operating 

Instructions. Failure to comply with the safety instructions accompanying this product could result in personal injury and/or property damage! Retain instructions 

for future reference.  AMT reserves the right to discontinue any model or change specifications at any time without incurring any obligation.

©2016  AMT Pump Company, A Subsidiary of The Gorman-Rupp Company, All Rights Reserved.

Periodic maintenance and inspection is required on all pumps to ensure proper operation. Unit must be clear of debris and sediment. Inspect for leaks and loose bolts. Failure to do so 

voids warranty.

High Head Centrifugal Pumps

Cast Iron, Bronze, and Stainless Steel Models

Refer to pump manual 1808-634-00 for General Operating and Safety Instructions.

CAST IRON UNITS

Pump construction is cast iron casing and adapter with a stainless steel 
impeller. Buna N type 21 mechanical shaft seal with carbon and ceramic wear 
faces. O-ring casing seal. Handles liquids from 40º to 180º F (4º to 82º C).

BRONZE UNITS

Pump construction is cast bronze casing and adapter with a stainless steel 
impeller. Viton type 21 mechanical shaft seal with carbon and ceramic wear 
faces. O-ring casing seal. Handles liquids from 40º to 200º F (4º to 93º C).

STAINLESS STEEL UNITS

Pump construction is cast 300 series stainless steel casing, adapter and 
impeller. Viton type 21 mechanical shaft seal with carbon and ceramic wear 
faces. O-ring casing seal. Handles liquids from 40º to 200º F (4º to 93º C).

MAINTENANCE

 

 

Make certain that the unit is disconnected from the power source before 
attempting to service or remove any components!

SHAFT SEAL REPLACEMENT

Refer to Figures 1 and 2.

REMOVAL OF OLD SEAL
IMPORTANT:

 Always replace both seal seat (Ref. No. 5) and seal head (Ref. 

No. 6) to ensure proper mating of components! Also, impeller seal (Ref. No. 9) 
should be replaced anytime impeller fastener (Ref. No. 10) has been removed.
1.  Remove fasteners (Ref. No. 3) connecting casing (Ref. No. 12) to adapter 

(Ref. No. 4).

2.  Remove casing.

 

Care should be taken not to pinch or “shave” casing seal (Ref. No. 11) 
between adapter and casing.

3.  Use a box and/or socket wrench to remove impeller fastener. Remove 

impeller seal and impeller (Ref. No. 8).

NOTE:

 Motor shaft must be held in place to remove impeller. Back of the 

motor either has slot in shaft (use large screwdriver to hold) or has 2 flats on 

motor shaft (use 7/16 open end wrench to hold). Impeller and impeller fastener 
unscrew CCW (Counter Clockwise) when looking at the front of pump.

IMPORTANT:

 Care should be taken to be sure that the same number of 

thickness of shim washers (Ref. No. 7) are replaced behind the impeller as was 
removed. Shim washers are located directly behind impeller and become loose 
as impeller is removed.
4.  The seal head can now be pulled from shaft.
5.  Pry seal seat from adapter.

INSTALLATION OF NEW SEAL

 

The precision lapped faces on mechanical seal are easily damaged. 
Handle your repair seal carefully. Do not touch polished seal faces.

IMPORTANT:

 Be sure that shaft shoulder does not damage polished face (see 

figure 1).

DESCRIPTION

These pumps are non-self-priming units designed for use where higher heads are needed to handle liquid transfer, heating and cooling application, where no 

suction lift is required. All models feature high efficiency closed impellers and continuous duty, 3450 RPM, 56J frame motors. The discharge port on all models 
can be rotated in 90º increments to accommodate specific applications. Casing working pressure to 150 psi (1034 kPa). These are manual units, no controls 

are supplied. Single phase units are capacitor start and have automatic thermal protection. Check motor wiring before putting unit into operation (see motor 

nameplate for specific wiring diagrams). All units are for use with nonflammable, non-abrasive liquids compatible with pump component materials.

Figure 1 - Mechanical Seal Replacement

Содержание 4895

Страница 1: ...ACEMENT Refer to Figures 1 and 2 REMOVAL OF OLD SEAL IMPORTANT Always replace both seal seat Ref No 5 and seal head Ref No 6 to ensure proper mating of components Also impeller seal Ref No 9 should be replaced anytime impeller fastener Ref No 10 has been removed 1 Remove fasteners Ref No 3 connecting casing Ref No 12 to adapter Ref No 4 2 Remove casing Care should be taken not to pinch or shave ca...

Страница 2: ... motor shaft with sealing surface facing seal seat see figure 2 Note A short run in period may be necessary to provide completely leak free operation 6 Screw impeller onto shaft Use screwdriver slot at rear of motor shaft opposite the threaded end to tighten impeller NOTE It may be necessary to remove plug in motor end cap to expose slot If removed be sure to reinstall plug AFTER pump is completel...

Страница 3: ... Series 4890 251 00 3 9 2016 For Repair Parts contact dealer where pump was purchased Please provide following information Model Number Serial Number if any Part description and number as shown in parts list Figure 2 Repair Parts Illustrations Circulator Pump ...

Страница 4: ...0 1 8 Impeller 4894 010 98 4896 010 98 4891 010 98 4903 010 98 4905 010 98 4901 010 98 1 includes Ref Nos 7 8 and 10 9 Impeller Seal Buna N Incl w Ref KIT Incl w Ref KIT Incl w Ref KIT Incl w Ref KIT Incl w Ref KIT Incl w Ref KIT 1 Impeller Seal Viton Incl w Ref KIT Incl w Ref KIT Incl w Ref KIT Incl w Ref KIT Incl w Ref KIT Incl w Ref KIT 1 Impeller Seal EPDM EPR Incl w Ref KIT Incl w Ref KIT Inc...

Страница 5: ...Specifications Information and Repair Parts Manual 489 490 Series 4890 251 00 5 9 2016 NOTES ...

Страница 6: ...Specifications Information and Repair Parts Manual 489 490 Series 4890 251 00 6 9 2016 NOTES ...

Страница 7: ......

Страница 8: ...www amtpump com ...

Отзывы: