Specifications Information and Repair Parts Manual

 

 

 

 

              

                                                          

3826-99 

 

 

3824-253-00 1 

2/2015 

 

Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, 
install, operate or maintain the product described. Protect yourself and others by observing all safety information. The Safety Instructions are contained 
in the General Operating Instructions. Failure to comply with the safety instructions accompanying this product could result in personal injury and/or 
property damage! Retain instructions for future reference

.  

AMT reserves the right to discontinue any model or change specifications at any time without 

incurring any obligation.

 

©2015 AMT Pump Company, A Subsidiary of The Gorman-Rupp Company, All Rights Reserved.

 

 
Periodic maintenance and inspection is required on all pumps to insure proper operation. Unit must be clear of debris and sediment. Inspect for leaks and loose bolts. Failure 
to do so voids warranty. 

 

2-Inch Thermoplastic Dewatering  
Pedestal Pump 

Refer to pump manual 1808-633-00 for General Operating and Safety Instructions. 

  

DESCRIPTION 

This self-priming (to 20 ft. lift) centrifugal pump includes a mechanical seal with carbon/ceramic wear faces and stainless steel spring, Buna N seals, and 
a built-in check valve. Clog resistant impeller is capable of handling solids up to 7/16" diameter. Pump includes molded carrying handle, rubber foot 
pads, and two 2" NPT pipe nipples. Handles liquids from 40º to 130º F (4º to 54º C). For use with nonflammable, non-abrasive liquids compatible with 
pump component materials. Applications include pumping clear, clean water, salt water, and some liquid fertilizers and herbicides. An optional EPDM 
Seal/O-ring/Flapper Kit (see Repair Parts List) is available for pumping “Alachlor Herbicides” (such as Monsanto's Lasso). If the fertilizer or herbicide is 
not compatible with Buna-N (standard) or EPDM (optional) rubber materials, do not use these pumps. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Performance Chart

 

 

Motor 

GPM at Total Head in Feet 

 

Requirement 

  

  

  

  

  

  

  

  

  

Max 

HP 

RPM 

10' 

20' 

30' 

40' 

50' 

60' 

70' 

80' 

90' 

Head* 

 

3600 8,460 7,680 6,840 6,000 5,100 4,140 3,180 2,100 840  94 

ft. 

(*) Shut-off; to convert to psi, divide by 2.31 

 

 

MAINTENANCE 
 

 

Make certain that power source is disconnected before 
attempting to service or disassemble any components! If power 
disconnect is out-of-sight, lock it in open position and tag to 
prevent application of power. 
 

MECHANICAL SEAL REPLACEMENT 

Refer to Figures 1, 2, and 3. 

 
IMPORTANT: 

Replace seal seat, (Ref. No. 27) and seal head (Ref. 

No. 28) at the same time to ensure proper mating of mechanical seal 
components! 
1. 

Unthread fasteners (Ref. No. 21), nuts (Ref. No. 31) and 
remove casing (Ref. No. 22) and casing seal (Ref. No. 13) 
from adapter (Ref. No. 9). Unthread fasteners (Ref. Nos. 15 
and 23) and remove volute (Ref. No. 24) and volute seal 
(Ref. No. 12) from adapter.  

2. 

Unthread impeller fastener (Ref. No. 14) and remove 
impeller (Ref. No. 25), impeller seal (Ref. No. 10) and 
impeller shims (Ref. No. 32). 

NOTE: 

To keep shaft from turning, hold impeller while unthreading 

impeller fastener. 
3. 

Pry seal seat from impeller recess with a screwdriver (See 
Figure 1). 

4. 

Remove adapter by unthreading adapter fasteners (Ref. 
Nos. 11 & 30) and fastener seals (Ref. No. 10). Press old 
seal head and adapter seal (Ref. No. 29) out of adapter by 
pushing from engine side. 

 

 

 

5. 

Clean adapter and impeller seal recesses before installing 
new pieces.  

6. 

Carefully wipe polished surface of new seal seat with a 
clean cloth. 7. Wet rubber portion of seal seat with a light 
coating of soapy water. 

Figure 1 – Mechanical Seal Replacement 