AMT 3100-99 Скачать руководство пользователя страница 1

 
Specifications Information and Repair Parts Manual

 

 

 

 

              

                                                          

3100-99 

 

 

3100-254-00 

07/2012 

 

Please  read  and  save  this  Repair  Parts  Manual.  Read  this  manual  and  the  General  Operating  Instructions  carefully  before  attempting  to  assemble, 
install, operate or maintain the product described. Protect yourself and others by observing all safety information. The Safety Instructions are contained 
in  the  General  Operating  Instructions.  Failure  to  comply  with  the  safety  instructions  accompanying  this  product  could  result  in  personal  injury  and/or 
property damage! Retain instructions for future reference

.  

AMT reserves the right to discontinue any model or change specifications at any time without 

incurring any obligation.

 

©2011 American Machine & Tool Co., Inc. of PA, A Subsidiary of The Gorman-Rupp Company, All Rights Reserved.

 

 
Periodic maintenance and inspection is required on all pumps to ensure proper operation. Unit must be clear of debris and sediment. Inspect for leaks and loose bolts. Failure 
to do so voids warranty. 

 

3-Inch Trash Pedestal Pump 

Refer to pump manual 1808-635-00 for General Operating and Safety Instructions. 

  

DESCRIPTION 

This self-priming (to 20 ft. lift) trash pump is a high capacity, heavy duty unit, designed for direct coupling drive or pulley 
drive.  Each  pump  is  equipped  with  mechanical  seal  to  reduce  the  likelihood  of  leakage  and  clog-resistant  cast  iron 
impeller capable  of handling solids  up to 1-1/2" diameter. The pump is designed  to handle  water containing mud, sand, 
sludge, solids and sewage. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Performance Chart 

 

 

 

 

 

 

 

 

 

Pump 

  

  

Sheave    

GPM at Total Head in Feet 

Speed 

Motor 

Motor   

Pump 

No. of   

  

  

  

  

  

  

  

  

  

RPM 

HP 

RPM 

PD 

PD 

Grooves 

5' 

10' 

20' 

30' 

40' 

50' 

60' 

70' 

80' 

1800 

1 ½  

1800 

3.0” 

3.0” 

10,600 

8,580 

1,320 

− 

− 

− 

− 

− 

− 

  

1 ½ 

3600 

2.5” 

5.0” 

2800 

1800 

5.5” 

3.5” 

17,880 

14,940 

12,000 

7,800 

2700 

− 

− 

− 

  

3600 

3.5” 

4.5” 

3600 

7 ½ 

1800 

7.0” 

3.5” 

21,360 

19,080 

16,620 

14,160 

10,200 

4,500 

2,100 

  

7 ½  

3600 

3.5” 

3.5” 

MAINTENANCE 

 

 

Always  disconnect  battery  cables  and  spark  plug 
wire  from  spark  plug  before  performing  any 
maintenance operation requiring disassembly of the 
pump. 

 

REPAIRS & REPLACEMENTS 

 

NOTE: 

First  examine  exploded  parts  illustration  which 

shows all parts and how they are related to one another. 
Different  degrees  of  dismantling  can  be  accomplished 
depending  on  what  areas  of  pump  are  to  be  reached. 

Note  that  entire  front  pump  assembly  can  be  removed 
by  first  removing  (6)  cap  screws  (Ref.  No.  31).  Impeller 
(Ref.  No.  17)  and  cutwater/wear  plate  (Ref.  No.  20)  are 
subject to wear only by abrasive action of sandy or dirty 
fluid. If badly worn, all these parts can be replaced easily 
and pump thus restored to full efficiency. 

 

 
 

IMPELLER & WEARPLATE RENEWAL 

 

When 

clearance 

between 

impeller 

and 

cutwater/wearplate  exceeds  1/16"  at  face  of  impeller  or 
1/8"  on  outside  diameter  of  impeller,  it  may  be 
necessary to take corrective action. Increased clearance 
can  cause  lengthened  priming  times  and  reduced 
pumping  capacity.  If  both  priming  and  capacity  of  your 
unit  are  satisfactory  for  your  application,  it  is 
recommended  that  no  corrective  maintenance  be 
performed  regardless  of  what  clearances  may  have 
developed,  since  increased  clearances  in  themselves 
are  not  generally  dangerous  to  your  pump.  Normally, 
new  pump  face  clearances  can  be  restored  by  simply 
shimming  behind  the  impeller.  (Add  impeller  shims  Ref. 
No.  21).  If  diameter  of  impeller  is  badly  worn  or  if  1/16" 
shim  washers  do  not  restore  clearances  to  less  than 
1/16" face dimension and/or 1/8" diametral clearance, it 
is  recommended  that  impeller  be  replaced.  This  is 
usually  all  that  is  required  since  only  on  unusually 
abrasive  surfaces  do  cast  iron  wearplates  show 
deterioration.

 

 