Specifications Information and Repair Parts Manual
3100-99
3100-254-00
1
07/2012
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble,
install, operate or maintain the product described. Protect yourself and others by observing all safety information. The Safety Instructions are contained
in the General Operating Instructions. Failure to comply with the safety instructions accompanying this product could result in personal injury and/or
property damage! Retain instructions for future reference
.
AMT reserves the right to discontinue any model or change specifications at any time without
incurring any obligation.
©2011 American Machine & Tool Co., Inc. of PA, A Subsidiary of The Gorman-Rupp Company, All Rights Reserved.
Periodic maintenance and inspection is required on all pumps to ensure proper operation. Unit must be clear of debris and sediment. Inspect for leaks and loose bolts. Failure
to do so voids warranty.
3-Inch Trash Pedestal Pump
Refer to pump manual 1808-635-00 for General Operating and Safety Instructions.
DESCRIPTION
This self-priming (to 20 ft. lift) trash pump is a high capacity, heavy duty unit, designed for direct coupling drive or pulley
drive. Each pump is equipped with mechanical seal to reduce the likelihood of leakage and clog-resistant cast iron
impeller capable of handling solids up to 1-1/2" diameter. The pump is designed to handle water containing mud, sand,
sludge, solids and sewage.
Performance Chart
Pump
Sheave
GPM at Total Head in Feet
Speed
Motor
Motor
Pump
No. of
RPM
HP
RPM
PD
PD
Grooves
5'
10'
20'
30'
40'
50'
60'
70'
80'
1800
1 ½
1800
3.0”
3.0”
1
10,600
8,580
1,320
−
−
−
−
−
−
1 ½
3600
2.5”
5.0”
1
2800
5
1800
5.5”
3.5”
2
-
17,880
14,940
12,000
7,800
2700
−
−
−
5
3600
3.5”
4.5”
2
3600
7 ½
1800
7.0”
3.5”
2
-
-
21,360
19,080
16,620
14,160
10,200
4,500
2,100
7 ½
3600
3.5”
3.5”
2
MAINTENANCE
Always disconnect battery cables and spark plug
wire from spark plug before performing any
maintenance operation requiring disassembly of the
pump.
REPAIRS & REPLACEMENTS
NOTE:
First examine exploded parts illustration which
shows all parts and how they are related to one another.
Different degrees of dismantling can be accomplished
depending on what areas of pump are to be reached.
Note that entire front pump assembly can be removed
by first removing (6) cap screws (Ref. No. 31). Impeller
(Ref. No. 17) and cutwater/wear plate (Ref. No. 20) are
subject to wear only by abrasive action of sandy or dirty
fluid. If badly worn, all these parts can be replaced easily
and pump thus restored to full efficiency.
IMPELLER & WEARPLATE RENEWAL
When
clearance
between
impeller
and
cutwater/wearplate exceeds 1/16" at face of impeller or
1/8" on outside diameter of impeller, it may be
necessary to take corrective action. Increased clearance
can cause lengthened priming times and reduced
pumping capacity. If both priming and capacity of your
unit are satisfactory for your application, it is
recommended that no corrective maintenance be
performed regardless of what clearances may have
developed, since increased clearances in themselves
are not generally dangerous to your pump. Normally,
new pump face clearances can be restored by simply
shimming behind the impeller. (Add impeller shims Ref.
No. 21). If diameter of impeller is badly worn or if 1/16"
shim washers do not restore clearances to less than
1/16" face dimension and/or 1/8" diametral clearance, it
is recommended that impeller be replaced. This is
usually all that is required since only on unusually
abrasive surfaces do cast iron wearplates show
deterioration.
Содержание 3100-99
Страница 6: ...Specifications Information and Repair Parts Manual 3100 99 3100 254 00 6 07 2012 NOTES...
Страница 7: ......
Страница 8: ...www amtpump com...