3-1
Installation Verification
Operator Manual
P129394-068
An Equipment Drawing showing utility and space requirements was
supplied with the sterilizer. Clearance space shown on the drawing
is necessary for ease of installation and to assure proper operation
and maintenance. Uncrating and Installation Instructions were also
furnished with the sterilizer. If any of these documents are missing,
contact STERIS Corporation and provide serial and model numbers
of the equipment. Replacement copies will be sent promptly.
3.1 Installation
Checklist
After installing this unit according to the instructions provided,
complete the following checklist to assure that installation is
complete and correct; or contact STERIS to scheduled a technician
to test the installation and demonstrate proper equipment operation.
3.1.1 Service Clearance
❑
Clearance as specified on the equipment drawing must be
available.
3.1.2 Plumbing Services
❑
Feed Water:
❑
All supply line shutoffs must be provided with lockout
capability.
❑
Backflow prevention is by others.
❑
Water Pressure
– measured (specification is 20 to 50 psig
[1.4 to 3.5 bar], dynamic). Water pressure supplied must be
within specifications as shown on the Equipment Drawing. If
pressure is too high, a regulator must be installed. If water
pressure is too low, equipment performance will be affected.
❑
Water Quality
– supplied must be within specifications.
Improper water quality adversely affects equipment
operation. Damage to the equipment due to improper water
quality is not covered under warranty.
❑
Steam Supply:
❑
Shutoffs (with provisions for lockout-tagout) located nearby.
❑
Supply piping adequately sized.
❑
Supply pressure measured (specification is 50 to 80 psig
[3.5 to 5.52 bar], dynamic).
❑
Drain Piping
must be sloped properly, and sized to handle
maximum waste flow from sterilizer.
CAUTION – POSSIBLE
EQUIPMENT DAMAGE:
Insufficient service clearance
will make repairs more
difficult and time-consuming.
!
CAUTION – POSSIBLE
EQUIPMENT DAMAGE: Piping
sized too small may cause
water hammer, resulting in
damage to the sterilizer.
!
CAUTION – POSSIBLE
EQUIPMENT DAMAGE: After
installation, it is mandatory to
brace piping at the drain
funnel so it will not move
vertically.
!
INSTALLATION VERIFICATION
3
Содержание 36 H
Страница 2: ......
Страница 14: ...xii P129394 068 Operator Manual Techniques of Sterilization LIST OF FIGURES Descrption Page ...
Страница 59: ...6 11 Sterilizer Operation Operator Manual P129394 068 Healthcare Capital Equipment ...
Страница 63: ...6 15 Sterilizer Operation Operator Manual P129394 068 Healthcare Capital Equipment ...
Страница 66: ...6 18 P129394 068 Operator Manual Sterilizer Operation Figure 6 9 Typical Printout of a Liquid Cycle ...
Страница 67: ...6 19 Sterilizer Operation Operator Manual P129394 068 Healthcare Capital Equipment ...
Страница 78: ...6 30 P129394 068 Operator Manual Sterilizer Operation Healthcare Capital Equipment ...
Страница 116: ...8 10 P129394 068 Operator Manual Routine Maintenance Healthcare Capital Equipment ...
Страница 140: ...9 24 P129394 068 Operator Manual Troubleshooting Healthcare Capital Equipment ...
Страница 152: ...10 12 P129394 068 Operator Manual Service Procedures Healthcare Capital Equipment ...