AMS AMS-R4000 RTU Скачать руководство пользователя страница 1

 

 

ALBORZ 

MICROSYSTEM 

  AMS-R4000 RTU 

  Modular Remote Terminal Unit 

   

 

 

 

 

 

Alborz MicroSystem  
3’rd floor, No. 8, Zare St, Azadi 
Ave, Tehran, IRAN 
 

 
 

 

 

 

 

  

+98-21-66431719 

   +98-28-32243671 

 

[email protected] 

 

            

 

            

+98-933-8785756

 

 

 

 
 
 

Alborz Micro System 

 

SCADA Software 

Provider 

 

Power Distribution 

Panel 

 

Wireless Radio 

Modem 

 

Design and 

Production of RTU & 

HMI 

 

 

Содержание AMS-R4000 RTU

Страница 1: ...Alborz MicroSystem 3 rd floor No 8 Zare St Azadi Ave Tehran IRAN 98 21 66431719 98 28 32243671 Info alborzmicrosystem com 98 933 8785756 Alborz Micro System SCADA Software Provider Power Distribution...

Страница 2: ...s without warranty of any kind either expressed or implied including but not limited to its particular purpose AMS reserves the right to make improvements and or changes to this manual or to the produ...

Страница 3: ...g Modules on a DIN Rail 2 3 Removing Modules from a DIN Rail 2 4 Connecting the Module Power 2 5 Connecting to the Network 2 6 Programming Environment 2 7 Factory Defaults 3 Modules Specifications and...

Страница 4: ...AMS R4000 RTU User s Manual...

Страница 5: ...EC61131 based programming environment pbs SoftLogic pbs SoftLogic is an IDE for developing function block based programs simulate and downloading to the RTU You can use the C C or LUA scripting langua...

Страница 6: ...ution with V I Selection AMS R4324 24 Channels Analog Input Module 16 Bit Resolution AMS R4404 4 Channels Analog Output Module AMS R4408 8 Channels Analog Output Module AMS R4504 4 Channels Thermocoup...

Страница 7: ...ignals RS 232 TxD RxD DTR DSR RTS CTS DCD RI GND RS 485 Data Data GND Protected Ground Do not Connect Protected Ground to GND or Power Input it can used for common potentiation of RS485 Signal if need...

Страница 8: ...1 Power supply and electromagnetic compatibility o IEC60870 3 Interfaces electrical characteristics o IEC60870 4 Performance Requirements EMC Standards o IEC 61000 4 2 Electrostatic Discharge Level 2...

Страница 9: ...AMS R4000 RTU User s Manual 1 5 Physical Dimensions CPU Module Dimension Unit mm...

Страница 10: ...AMS R4000 RTU User s Manual IO Module Dimension Unit mm...

Страница 11: ...ms Off Network searching 1800ms On 200ms Off IDLE 180ms On 180ms Off Data transferring Always On Voice Call Always Off Modem is turned off Ethernet LED On the Plug Eth1 2 Yellow Light on Link present...

Страница 12: ...AMS R4000 RTU User s Manual...

Страница 13: ...formation to the master of the SCADA system The secure and reliable CAN protocol is used to communicate the CPU and I O modules This communication occurs through an expansion connector CAN communicati...

Страница 14: ...DIN Rail CPU Module In order to installing the CPU module on a DIN Rail simply perform the following steps Insert the top of the DIN Rail bracket into the top of the DIN Rail Rotate the top of the mod...

Страница 15: ...these steps CPU modules installation is completed I O Modules In order to installing the I O module on a DIN Rail besides the other modules simply perform the following steps Insert the top of the DI...

Страница 16: ...te the top of the module downwards until the bracket snap into the DIN Rail After performing these steps IO module installation is completed Connectors In order to installing the module connectors sim...

Страница 17: ...it is the first I O module use the AMS R4001 expansion connector in order to communicate between the CPU and I O module If it is not the first I O module use AMS R4002 expansion connector in order to...

Страница 18: ...er performing these steps installation is completed 2 3 Removing Modules from a DIN Rail In order to removing the CPU and I O module from a DIN Rail simply perform the following steps Remove the expan...

Страница 19: ...AMS R4000 RTU User s Manual Use a screwdriver in order to push down the spring loaded part of the bracket Rotate the bottom of the module upwards and then remove it from the DIN Rail...

Страница 20: ...I MDI X mode in which case the port s pinouts are adjusted automatically depending on the type of Ethernet cable used straight through or cross over The default configuration of the LAN2 Ethernet port...

Страница 21: ...485 serial ports of the RTU to each other by wire jumping Data3 to Data4 and Data3 to Data4 Connect the power supply After finishing the booting process which takes about 30 second buzzer of the devic...

Страница 22: ...AMS R4000 RTU User s Manual...

Страница 23: ...is 1 kHz The modules have 16 and 32 LEDs to indicate the signal state at the inputs The required power of these modules are supplied by the expansion connector from the AMS R4000 CPU module Specifica...

Страница 24: ...AMS R4000 RTU User s Manual Wiring Diagram...

Страница 25: ...32 LEDs to indicate the signal state at the outputs The required power of these modules are supplied by the expansion connector from the AMS R4000 CPU module Moreover the modules require a 12 to 40 VD...

Страница 26: ...AMS R4000 RTU User s Manual Wiring Diagram Max Load per Channel 1W Max Load power per Channel is 1W...

Страница 27: ...at the outputs The required power of these modules are supplied by the expansion connector from the AMS R4000 CPU module Specifications AMS R4216RLY 16 Channels Relay Digital Output Module Parameters...

Страница 28: ...AMS R4000 RTU User s Manual Wiring Diagram...

Страница 29: ...flow pressure temperature and other analog transmitters The modules are able to monitor and process wide range of the voltage signal in the range of 0 to 5 V 0 to 10 V 5 to 5 V and the current signal...

Страница 30: ...Channels Input Type Voltage Current Differential Single Ended As your order Input Voltage Range 0 to 5 V 0 to 10 V 5 to 5 V Input Current Range 0 to 20 mA 4 to 20 mA Input Impendence 120 Ohms 250 Ohms...

Страница 31: ...he above figure the AMS 4308 EM the AMS 4316 EM Modules support both of the current and Voltage input mode It should be noted that if each one of the input channels of the device is not connected to y...

Страница 32: ...ignal in the range of 0 to 5 V 0 to 10 V 5 to 5 V 10 to 10 V and the current signal in the range of 0 to 20 mA 4 to 20 mA by using the microprocessor controlled D A converter Conversion range and slew...

Страница 33: ...ange 0 to 5 V 0 to 10 V 5 to 5 V 10 to 10 V Current Output Range 0 to 20 mA 4 to 20 mA Resolution in Ranges 16 bits Voltage Slew Rate 0 0625 to 64 V sec Current Slew Rate 0 125 to 128 mA sec Output Im...

Страница 34: ...t voltage measurement accuracy of the modules is near to 0 15 of Full Scale Range FSR which is digitized and converted to the temperature with 19 bits resolution All of the thermocouple channels of th...

Страница 35: ...400 C 52 18 0 C to 400 C 55 C to 125 C Specifications AMS R4504 4 Channels Thermocouple Input Module AMS R4508 8 Channels Thermocouple Input Module Parameters Value Inputs per Module AMS R4504 4 Chan...

Страница 36: ...odule AMS R4508 8 Channels Thermocouple Input Module Parameters Value Digital Sensor Input Capability 2 Channels Digital Sensor DS18B20 stainless still Waterproof DS18B20 Environmental sensor Wiring D...

Страница 37: ...AMS R4604 4 Channels RTD Input Module AMS R4608 8 Channels RTD Input Module Parameters Value Inputs per Module AMS R4604 4 Channels AMS R4608 8 Channels Input RTD Resistance PT100 PT1000 100 to 1k at...

Страница 38: ...measured data can be used to analyze the quality of the network make corrections in the network selecting compensators and reduce the losses and consumption management The device is able to transfer...

Страница 39: ...Yes Accuracy 0 5 of the FSR Class 0 5 Frequency 45 to 65 Hz Display TFT LCD Data Recording Capability Yes Recording Period Software selectable from 1 min to 1 hour Auxiliary supply 85 280 VAC 9 36 VD...

Страница 40: ...me page 12 shows device setting parameters and last page shows communication status Following figures show some of these pages and how you can switch between them First page shows the measured values...

Страница 41: ...S R4000 RTU User s Manual Press Enter button to see the parameter type of the shown value Press up or down button to navigate in the pages Press Enter button to see the parameter type of the shown val...

Страница 42: ...s Manual By reusing the up or down button you can switch between other pages which shown the line voltages active reactive and apparent power active reactive and apparent energy power factor and frequ...

Страница 43: ...ssword for 3 times device will be locked for 10 min After this time period until 2 hours if user do it again the device will be locked and need a factory code to unlock Main Menu Page 13 Communication...

Страница 44: ...analog input 8 channels of digital input 2 channels of temperature sensor DS18B20 and 4 channels of digital relay output The AMS R4932 supports 16 channels of digital input and 16 channels of transist...

Страница 45: ...dule supports both of the current and Voltage input mode It should be noted that if each one of the input channels of the device is not connected to your Transducer or Sensor simply do a wire jumping...

Страница 46: ...AMS R4000 RTU User s Manual...

Страница 47: ...cuments will be find there as follow Driver AMS R4000 RNDIS USB Ethernet driver in order to simulate Ethernet connection over USB that makes communication and programming very simple Software pbs Soft...

Страница 48: ...AlborzMicroSystem info AlborzMicroSystem com www AlborzMicroSystem com Copyright 2017 AMS Co AMS reserves the right to make changes to specifications of products described at any time without notice...