Amprobe RS-3 Скачать руководство пользователя страница 1

5. With Test Leads Shorted-

Line up pointer with "0'' mark on   
ohms scale by turning Small  
Black Knob on right side of   
instrument (Fig 17)

NOTE: If ohmmeter zero adjust 
knob does not line pointer up on zero
mark, replace battery with a new one.
Oxidation on base of battery can cause
poor contact. Sand lightly to assure good
contact.

6. To Measure Resistance 

between any two points on a 
device, simply apply the clip lead  
and the ohmmeter attachment  
probe tip and read pointer.

HOW TO READ OHMMETER SCALE
The ohmmeter scale is located on the flat plate along the righthand edge of the
window. The zero mark (beginning) is on top of the scale while the infinity mark

” ends the scale.

OPTIONALEXTENDO LEADS
FOR FASTER AND EASIER VOLTAGE TESTING

EXTENDO TESTLEADS. Cal. No VLK-411R. have
5 inch long insulated probes for a man-sized grip.
One probe clamps between instrument jaws.
Optional alligator clip adaptor (Cat No VRC-320)
converts probe so it can be fastened to test point.
Probe tips are replaceable (Cat No VPT) 

Fig 19

FACTORY SERVICE

If the instrument fails to operate, check battery, test leads, etc and replace as
necessary. If the instrument still malfunctions, please call the phone number
listed below:    
Tel:  954-499-5400 - 800-327-5060
Outside the U.S.A. the local Amprobe representative will assist you.

RANGE-EXPANDING ACCESSORIES

*Intermittent duty
All of the above are clamp-on type transformers. Models CT-50-1 (six link) and
CT-50-2 (four link) are flexible link construction.
Request Cal. No, AAD38.

Mode

A50-1

CT-50-1
CT-50-2

Ratio

10 to 1
50 to 1
50 to 1

Maximum Range Capability

1,200 amperes*
6,000 amperes*
3,600 amperes*

OTHER ACCESSORIES & REPLACEMENT PARTS

Model 

Description

VL-11R..............................................................................Leads
VLK-411R.........................................................................Extendo Leads
VPT...................................................................................Replacement Tips
OHB-3HE .......................................................................Ohmmeter Attachment
8AG-360x023....................................................................Fuse - 600V. 1Amp
A-47L................................................................................Energizer
ADP-46.............................................................................Ground adaptor
912....................................................................................Buttery AAA
VRC-320...........................................................................Alligator Clip

Reg. U.S. Pat. office
Patent nos. 2,663,845
Others Pending

HOW TO INSTALL
FUSE AND BATTERY

Unscrewbaseofohmmeterbattery/fuse attachment
insert fuse (Use Litte/fuse type 8AG - 360x023
1AMPfast blow) and AAAbattery (Cal No 912, not
supplied) into probe end as shown in figure.
Screw base on to probe.

HOW TO USE AS AN OHMMETER

CAUTION:

FOR RS-3 MODELS

.

Make certain no voltage is present in circuit before connecting ohmmeter.
The ohmmeter is fused to help protect it against a misapplication of voltage
but under certain conditions it is still possible to damage the meter and/or
cause personal injury. Use only OHB-3HE ohmmeter attachment with fuse
#8AG-360x023. 1 Amp 600V.

Fig 13

Fuse 
Battery
Case

Fuse

Battery

Lid

1. Insert either the Red or Black Voltage 

Lead into the Left Voltage Receptacle
at bottom of instrument case (Fig. 14).

2. Insert ohmmeter battery/fuse attachment 

into the jack on the right side of the  
instrument just below the ohmmeter Zero 

Adjust Knob. Seat plug to bottom for 

good connection (Fig. 15).

3Set range Selector so that the 150 volt 

red scale appears in window.

4Ohmmeter Scale Adjustment with test 

Leads Open-Pointer should line up with 
division marked “

”  on OHMS SCALE.

Turn Pointer Zero Adjust Screw if neces-
sary (Fig. 16).

IMPORTANT:

Read "Precaution for Personal and Instrument Safety" 

before using instrument.

Fig 14

Fig 15

Fig 16

Zero

Adjust

Knob

Zero

Adjust

Knob

Fig 17

Fig 18

Fig 19

Zero

Adjust

Knob

NOTE: If you fail to get an ohmmeter indication or the indication is
intermittent, before replacing the battery or fuse, lightly sand the base
of the battery with fine sandpaper. This will remove any oxidation that
could be causing poor or intermittent contact.

CAUTION: Makecertainthatcircuit  
is disconnected from line before 
takinganyresistance measurements.

|

AMPROBE

®

Miramar, FL

www.amprobe.com

Phone: 954-499-5400

Fax: 954-499-5454

P/N 915741 Rev.B

OPERATING

INSTRUCTIONS

for

AMPROBE

®

Rotary Scale

Clamp-on

Model RS-3

See Precautions for Personal and 

Instrument Safety on Page 1

SPECIFICATIONS

AC Voltage Ranges: 0- 150/300/600
AC Amp Ranges: 0-6/15/40/100/300
Ohms : 25 Ohms mid-scale
Frequency Response: 50/60 Hz
Accuracy: Volts and Amps: – ± 3% of Full Scale 50 / 60 Hz

based on sinusoidal waveform
Ohms – ±3% of arc.

Duty: Continuous
Case Breakdown: 3500 Volts
Ohmmeter Protection: Ohm circuit is fuse protected to 600 Volts

PAGE 5

PAGE 4

Содержание RS-3

Страница 1: ...rt fuse Use Litte fuse type 8AG 360x023 1AMPfast blow and AAAbattery Cal No 912 not supplied into probe end as shown in figure Screw base on to probe HOW TO USE AS AN OHMMETER CAUTION FOR RS 3 MODELS Make certain no voltage is present in circuit before connecting ohmmeter The ohmmeter is fused to help protect it against a misapplication of voltage but under certain conditions it is still possible ...

Страница 2: ...nductor before attempting to read the meter 6 If pointer indicates below 40 Amps Fig 5 DON T READ YET IMPORTANT READ Precautions for Personal and Instrument Safety before using instrument HOW TO TAKE CURRENT READINGS See Pages 2 and 5 for range expanding accessories All ampere ranges are printed black 7 Set Rotary scale selector to next current range until a reading is obtained in the upperhall of...

Страница 3: ...12 no suministrada en el extremo de la sonda tal y como se muestra en la figura Enrosque la base en la sonda CÓMO UTILIZARLO COMO OHMETRO PRECAUCIÓN PARALOS MODELOS RS 3 Asegúrese de que no hay voltaje presente en el circuito antes de conectar el ohmetro El ohmetro cuenta con fusible para ayudar a protegerlo contra una aplicación errónea de voltaje pero bajo ciertas condiciones resulta posible tod...

Страница 4: ...ar el instrumento lea las Precauciones para la Protección Personal y del Instrumento CÓMO HACER MEDICIONES DE CORRIENTE Vea las páginas 2 y 5 para los accesorios de expansión de gama Todas las gamas de amperios están impresas en negro 7 Ajuste el selector de escala giratoria a la gama de corriente sigu iente hasta que obten ga una lectura en la mitad superior de la escala Figura 6 OK REALICE LALEC...