Temposonics
®
R-Series
V
POWERLINK
Operation Manual
I 7 I
3.3 Order code of Temposonics
®
RFV
a
Sensor model
R
F V
Flexible rod
b
Design
B
Base unit
M
Threaded fl ange M18×1.5-6g (standard)
S
Threaded fl ange ¾"-16 UNF-3A (standard)
Section
c
is intentionally omitted.
d
Stroke length
X X X X X M
00150…20000 mm
Stroke length (mm)
Ordering steps
150… 1000 mm
50 mm
1000… 5000 mm
100 mm
5000…10000 mm
250 mm
10000…15000 mm
500 mm
15000…20000 mm
1000 mm
X X X X X U
0006.0…0787.0 in.
Stroke length (in.)
Ordering steps
6… 40 in.
2 in.
40…197 in.
4 in.
197…394 in.
10 in.
394…591 in.
20 in.
591…787 in.
40 in.
Non standard stroke lengths are available;
must be encoded in 5 mm/0.1 in. increments
.
e
Number of magnets
X X
01…30 position(s) (1…30 magnet(s))
f
Connection type
D 5 6
2 × M12 female connectors (D-coded),
1 × M8 male connector
D 5 8
2 × M12 female connectors (D-coded),
1 × M12 male connector (A-coded)
g System
1
Standard
h Output
U 3 0 1
POWERLINK, position and velocity
(1…30 magnet(s))
U 3 1 1
POWERLINK, position and velocity,
internal linearization (1…30 magnet(s))
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
R
F V
D 5
1
U 3 0 1
a
b
d
e
f
g
h
NOTICE
• Specify the number of magnets for your application and order the
magnets separately.
• The number of magnets is limited by the stroke length.
The minimum allowed distance between magnets (i.e. front face
of one to the front face of the next one) is 75 mm (3 in.).
• Use magnets of the same type for multi-position measurement.