Temposonics
®
R-Series
V
Analog
Operation Manual
I 66 I
8.4
Technical data Temposonics
®
RDV
Output
Analog
Voltage: 0…10 /10…0/−10…+10/+10…−10 VDC (min. controller load > 5 k
Ω
)
Current: 4(0)…20/20…4(0) mA (min./max. load 0/500
Ω
)
Measured output variables
Position for one or two position magnets
Po speed (without direction) or velocity (with direction) for one position magnet
Position for one position temperature inside the sensor electronics housing
Measurement parameters
Position measurement
Null/Span adjustment
100 % of electrical stroke
Resolution
16 bit (internal resolution 0.1 µm)
Update time
Stroke length
≤ 200 mm
≤ 350 mm
≤ 1200 mm
≤ 2400 mm
≤ 4800 mm
≤ 5080 mm
Update time
0.25 ms
0.333 ms
0.5 ms
1.0 ms
2.0 ms
2.2 ms
Linearity deviation
8,9
Stroke length
≤ 500 mm
> 500 mm
Linearity deviation
≤ ±50 μm
< ±0.01 % F.S.
Repeatability
<
±0.001 % F.S. (minimum ±1 µm)
Hysteresis
< 4 µm typical
Temperature coefficient
< 30 ppm/K typical
Velocity measurement
Range
0.01…10 m/s or 1…400 in./s
Deviation
≤ 0.05 %
Resolution
16 bit (minimum 0.01 mm/s)
Operating conditions
Operating temperature
−40…+85 °C (−40…+185 °F)
Humidity
90 % relative humidity, no condensation
Ingress protection
Sensor electronics IP67 (with professional mounted housing and connectors)
Measuring rod with connecting cable for side cable entry IP65
Measuring rod with single wires and flat connector with bottom cable entry IP30
Shock test
100 g/11 ms, IEC standard 60068-2-27
Vibration test
10 g/10…2000 Hz, IEC standard 60068-2-6 (excluding resonant frequencies)
EMC test
Electromagnetic emission according to EN 61000-6-3
Electromagnetic immunity according to EN 61000-6-2
The RDV sensors fulfill the requirements of the EMC directives 2014/30/EU, UKSI 2016 No. 1091 and
TR CU 020/2011 under the condition of an EMC compliant installation
10
Operating pressure
350 bar (5076 psi)/700 bar (10,153 psi) peak (at 10 × 1 min) for sensor rod
Magnet movement velocity
Any
Design/Material
Sensor electronics housing
Aluminum (painted), zinc die cast
Sensor rod with flange
Stainless steel 1.4301 (AISI 304)
RoHS compliance
The used materials are compliant with the requirements of EU Directive 2011/65/EU and
EU Regulation 2015/863 as well as UKSI 2022 No. 622
Stroke length
25…2540 mm (1…100 in.) for pressure-fit flange »S«
25…5080 mm (1…200 in.) for all threaded flanges
8/
With position magnet # 251 416-2
9/
For rod style »S« the linearity deviation can be higher in the first 30 mm (1.2 in.) of stroke length
10/
The cable between the sensor element and the sensor electronics housing must be mounted in an appropriately shielded environment
Technical data
“