8.3
Technical data Temposonics
®
RFV
Output
Analog
Voltage: 0…10 /10…0/−10…+10/+10…−10 VDC (min. controller load > 5 k
Ω
)
Current: 4(0)…20/20…4(0) mA (min./max. load 0/500
Ω
)
Measured output variables
Position for one or two position magnets
Po speed (without direction) or velocity (with direction) for one position magnet
Position for one position temperature inside the sensor electronics housing
Measurement parameters
Position measurement
Null/Span adjustment
100 % of electrical stroke
Resolution
16 bit (internal resolution 0.1 µm)
Update time
Stroke length ≤ 200 mm ≤ 350 mm ≤ 1200 mm ≤ 2400 mm ≤ 4800 mm ≤ 7620 mm ≤ 10,000 mm ≤ 20,000 mm
Update time
0.25 ms
0.333 ms 0.5 ms
1.0 ms
2.0 ms
5.0 ms
7.5 ms
15.0 ms
Linearity deviation
6
< ±0.02 % F.S. (minimum ±100 μm)
Repeatability
< ±0.001 % F.S. (minimum ±2,5 μm) typical
Hysteresis
< 4 µm typical
Temperature coefficient
< 30 ppm/K typical
Velocity measurement
Range
0.01…10 m/s or 1…400 in./s
Deviation
≤ 0.05 %
Resolution
16 bit (minimum 0.01 mm/s)
Operating conditions
Operating temperature
−40…+85 °C (−40…+185 °F)
Humidity
90 % relative humidity, no condensation
Ingress protection
IP30 (IP65 rating only for professional mounted guide pipe and if mating connectors are correctly fitted)
Shock test
100 g/6 ms IEC standard 60068-2-27
Vibration test
5 g/10…2000 Hz, IEC standard 60068-2-6 (excluding resonant frequencies)
EMC test
Electromagnetic emission according to EN 61000-6-3
Electromagnetic immunity according to EN 61000-6-2
The RFV sensors fulfill the requirements of the EMC directives 2014/30/EU, UKSI 2016 No. 1091 and
TR CU 020/2011 under the condition of an EMC compliant installation
7
Magnet movement velocity
Any
Design/Material
Sensor electronics housing
Aluminum (painted), zinc die cast
Sensor flange
Stainless steel 1.4305 (AISI 303)
Sensor rod
Stainless steel conduit with PTFE coating
RoHS compliance
The used materials are compliant with the requirements of EU Directive 2011/65/EU and
EU Regulation 2015/863 as well as UKSI 2022 No. 622
Stroke length
150…20,000 mm (6…787 in.)
Mechanical mounting
Mounting position
Any
Mounting instruction
Please consult the technical drawings on
6/
With position magnet # 251 416-2
7/
The flexible sensor element must be mounted in an appropriately shielded environment