NOTICE

Use only the same magnet type for multi-position 

measurement!

4.3 Multi-position measurement distances

Multi-position measurement with G-Series GP / GH sensors 

and Start / Stop output is possible, with a simultaneous  

measuring up to 9 positions

The stroke length influences the maximum number of mag-

nets. Note the minimum distance between the magnets.

G-Series GP with U-magnet

≥ 75 (≥ 3)

G-Series GP with block magnet

≥ 75 (≥ 3)

G-Series GH with block magnet

≥ 75 (≥ 3)

G-Series GP with magnet slider »S«, »N«, »V«, »G«

≥ 75 (≥ 3)

G-Series GH with ring- / U-magnet

≥ 75 (≥ 3)

Placement of installation and cabling have decisive influence 

on the sensor’s electromagnetic compatibility (EMC). Hence 

correct installation of this active electronic system and the 

EMC of the entire system must be ensured by using suitable 

metal connectors, shielded cables and grounding. Overvolt-

ages or faulty connections can damage its electronics despite 

protection against wrong polarity.

NOTICE

Never connect / disconnect the sensor when voltage is 

applied.

NOTICE

Do not mount the sensors in an area of strong magnetic or 

electric noise fields.  

Sensors must be grounded via ground lug on the sensor 

electronics housing.

Instructions for connection

•  Use low-resistant twisted pair and shielded cables. Connect 

the shield to ground externally via the controller equipment.

•  Keep control and signal cables separate from power cables 

and sufficiently far away from motor cables, frequency 

inverters, valve lines, relays, etc..

•  Use only connectors with metal housing and connect the 

shielding to the connector housing.

•  Keep the connection surface at both shielding ends as 

large as possible. Connect the cable clamps to function as 

a ground.

•  Keep all non-shielded leads as short as possible.

•  Keep the earth connection as short as possible with a large 

cross section. Avoid ground loops.

•  With potential differences between machine and electronics 

earth connections, no compensating currents are allowed 

to flow across the cable shielding.  

Recommendation:  

Install potential compensating leads with large cross 

section, or use cables with separate double shielding,  

and connect only one end of the shield.

•  Use only stabilized power supplies in compliance with the 

specified electrical ratings.

5.  Electrical connections

Sensor grounding

Controlling design dimensions are in millimeters and  
measurements in ( ) are in inches

Содержание Temposonics G Series

Страница 1: ...Magnetostrictive Linear Position Sensors Brief Instruction G Series...

Страница 2: ...ructions for use in explosion hazardous areas 5 2 5 Warranty 5 2 6 Return 5 2 7 Maintenance removal 5 3 Identification 6 3 1 Temposonics G Series GP 6 3 2 Temposonics G Series GH 6 3 3 Temposonics G S...

Страница 3: ...escribed product or connected devic es In this documentation safety information and warnings to avoid danger that might affect the life and health of operating or service personnel or cause material d...

Страница 4: ...e sensor might be damaged Do not step on the sensor The sensor might be damaged 2 Safety instructions Manuals Software 3D models available at www temposonics com Forseeable misuse Consequence Lead com...

Страница 5: ...anty Temposonics grants a warranty 2 period for the Temposonics position sensors and supplied accessories relating to material defects and faults that occur despite correct use in accordance with the...

Страница 6: ...sor rod sensor GP S 0850M D60 1 V0 0 10 V FNr 1601 0376 Sensor model Stroke length e g 850 mm Connection type Output version Week Year Part no Output Production no Threaded ange M18 1 5 6g or 16 UNF 3...

Страница 7: ...ilable output Analog rod sensor with redundant electronics Position magnet U or ring magnet Pressure proof rod with sensor element Threaded flange M18 1 5 6g or 16 UNF 3A Connector or cable outlet Sen...

Страница 8: ...t not be exceeded Take care to mount the primary sensor axis in parallel to the magnet path in order to avoid damage to the carriage magnet and sensor rod Controlling design dimensions are in millimet...

Страница 9: ...gth 5000 mm 196 85 in Start position 48 5 1 91 4 2 Mounting dimensions of G Series G Series GP with magnet slider S N V G Sensor electronics housing Reference edge of mounting Start position 12 0 47 S...

Страница 10: ...strong magnetic or electric noise fields Sensors must be grounded via ground lug on the sensor electronics housing Instructions for connection Use low resistant twisted pair and shielded cables Conne...

Страница 11: ...le Color Function GY Position PK DC Ground YE USB programmer GN USB programmer BN 24 VDC 15 20 WH DC Ground 0 V Start Stop LED status Green Red Information ON OFF Normal function ON Flashing Missing e...

Страница 12: ...6 70 29 91 281 E mail info sca temposonics com CHINA Branch Of ce Phone 86 21 2415 1000 2415 1001 E mail info cn temposonics com JAPAN Branch Of ce Phone 81 3 6416 1063 E mail info jp temposonics com...

Отзывы: