2.2.15 TPA or Breaker Output Wiring (Connectorized Versions)
WARNING! Before connecting output power cables, make sure input power to the panel is turned off.
55. P40 output connectors are available in two sizes, #12-10 AWG and #8-6 AWG. Depending on the Output
connector, crimp terminals onto one end of #12 to #6 AWG copper wires using Daniels M300BT crimp tool
or Burndy Y122CMR crimp tool. (Work with one output wire at a time.)
56. Insert terminals into plug housing as shown in Fig. 2-19 and Fig. 2-20. The battery
terminal goes in the “D”
shaped position on the connector. The return terminal goes in the round housing position.
NOTE:
A good way to remember is “Round = Return”.
57. Insert retainer into plug housing as shown in Fig. 2-21 Ensure the retainer flanges are inserted into the
connector first.
Fig. 2-19: Insert Crimped Terminals
Fig. 2-20: Connector Front View
Fig. 2-21: Insert Retainer
“D” shaped position: Battery
“O” shaped position: Return