Ampfibian AMPFIBIAN RV-PLUS Скачать руководство пользователя страница 1

Suitable for model: AMPFIBIAN RV-PLUS

ADAPT TO YOUR 

SURROUNDINGS

[email protected]

www.ampfibian.com.au

Freecall: 1800-FIBIAN

(1800 342-426)

1791-INSTRUCT-PLUS-B

Every Ampfibian product is thoroughly inspected and tested before leaving our 

factory. Ampfibian Pty. Ltd. limits this warranty against defective workmanship 

and faulty materials under normal use for twentyfour (24) months from date of 

purchase (proof of date of purchase must be provided) and undertakes at its 

option to repair or replace each product or part thereof on condition that:
• The product has not been subject to misuse, neglect, accidents or alterations;

• The unit has been used and maintained as per the instructions.
Ampfibian Pty. Ltd. is not liable for any consequential damage to either people, 

work or facilities from using the Ampfibian. 
Please ensure Ampfibian is actually faulty before returning it, by testing it on a 

different power circuit and with a different appliance. Please see the “

Return & 

Refund Policy

” page on our website or contact us for details. All shipping costs 

are the responsibility of the customer.
Please staple your purchase receipt (or a copy) to this document. You will be 

asked to provide a filled-out copy of this form and proof-of-purchase in the 

event of a warranty claim.

DATE OF PURCHASE:

PURCHASED FROM:

PURCHASER’S NAME:

CONTACT INFORMATION:

LIKE US ON FACEBOOK!

TM

No. DESCRIPTION

1 LID
2  CORD SEAL (LID)
3  HOUSING SEAL
4  15A SOCKET WITH LIGHT
5 RCD/MCB*
6  CORD SEAL (BODY)
7  LID LATCHES
8  DEVICE LEAD (NOT SUPPLIED)

    *) RCD = Residual Current Device
 

MCB = Miniature Circuit Breaker

9  PLUG & FLY-LEAD
10  TEST PUSH BUTTON
11  RCD/MCB TOGGLE SWITCH

12  PADLOCK ATTACHMENT

USING THE RV-PLUS:

1.  With nothing plugged in, connect    

 

the RV-PLUS’s plug (9) directly into power  

 

supply (wall) socket and switch power  

 

supply ON.

2.  Switch RV-PLUS ON (11). If unit trips,  

 

unplug it and contact us. DO NOT USE or  

 

continue to next step.

3.  Press test button labelled “T” (10). If  

 

switch (11) trips OFF continue to step 4. 

 

If switch (11) DOES NOT trip when test

 

button pressed, unplug RV-PLUS and

 

contact us. DO NOT use RV-PLUS or  

 

continue to step 4.

4.  Connect device lead (8) to RV-PLUS  

 

socket. Avoid any strain on the lead.

5.  Connect RV-PLUS lead (8) to  

 

 

operating device (caravan, RV, etc.). 

6.  Switch RV-PLUS to ON position (11).

LID (1) MUST BE LATCHED CLOSED 

BEFORE USE. INSPECT SEALS (2,3,6) FOR 

DAMAGE AND/OR OBSTRUCTION. DO NOT 

USE IF LID, SEALS OR LATCHES (7) ARE 

DAMAGED OR INOPERABLE.

IF RV-PLUS TRIPS IN SERVICE:

First rule out that the RV-PLUS is at fault by 

performing the above test procedure. The 

RV-PLUS will trip due to overload or an earth 

leakage fault. If you are unsure of the cause, 

or you believe there is an earth leakage fault, 

turn off all power and contact a licensed 

electrician. If you believe there is an 

overload, switch off or unplug some of the 

appliances and reset the RV-PLUS.
Electricity can be dangerous! RCDs (Residual 

Current Devices) are not a substitute for 

basic electrical safety precautions. RCDs are 

additional protection and will not prevent 

shock, but will minimise the effect. Do not 

use this device if it fails to operate correctly 

in accordance with these instructions. 
The RV-PLUS is rated 240 Volts with a 

maximum current rating of 10 Amperes (A).
Do not try to open or repair the RV-PLUS 

yourself. No user-serviceable parts are 

inside. Test RV-PLUS before each use.

This device will only protect against faults to 

earth through the body, but not against 

active to neutral faults.
This device must be connected DIRECTLY to 

an outlet socket. It must not be connected 

via cord extension sets.

OPERATING TEMPERATURE 2˚C TO 40˚C.

Wet seals will freeze and will not recover 

their shape until thawed. Do not open frozen 

unit until thawed. Opening frozen unit may 

result in damage to seals.

DO NOT EXPOSE TO PETROL, OIL, SOLVENTS, 

POOL CHEMICALS, ETC.!
DO NOT USE IN HAZARDOUS LOCATIONS!
DO NOT USE IF DAMAGED!
DO NOT DISASSEMBLE!
INGRESS PROTECTED TO IP-55.
DO NOT DROP OR IMMERSE IN WATER!
REMOVE CONDENSATION / MOISTURE WITH A 

SOFT ABSORBENT CLOTH.
ONLY CONNECT TO POWER IF UNIT IS 

COMPLETELY DRY INSIDE.
TURN OFF POWER SUPPLY BEFORE HANDLING 

CONNECTIONS IN WET CONDITIONS!
STORE IN A DRY PLACE OUT OF

DIRECT SUNLIGHT.
ENSURE THERE IS NO GAP VISIBLE THROUGH 

CORD SEALS WHEN CLOSED! IF REQUIRED, 

LEAVE LID OPEN UNTIL CORD SEALS HAVE 

FULLY RECOVERED.
THIS PRODUCT IS NOT INTENDED FOR 

PERMANENT INSTALLATION. DO NOT BURY!
SUITABLE FOR ORDINARY AND HEAVY-DUTY 

EXTENSION LEADS TO 12mm DIAMETER.
TO BE USED WITH 10A (2400W) 

MAXIMUM LOAD.

ON

OFF

Please keep warranty information and instructions with you.

Only send your warranty information to Ampfibian in case of a warranty claim.

INSTRUCTIONS

RCD/MCB may vary from illustration. 

All RCD/MCBs have an up/down 

toggle switch where UP is ON; and a 

test push-button marked “T”.