Ampetronic ILD300 Скачать руководство пользователя страница 1

ILD300 HANDBOOK 

Handbook Contents 

•  Safety 

•  Introduction 

•  Quick Start 

•  Overview 

•  Installation 

•  Troubleshooting 

•  Accessories 

•  Technical Specification 

•  Warranty 

•  Declaration of Conformity 

Box Contents 

1 x ILD300 

1 x Loop connector 

1 x Installation & Commissioning 

Handbook 

1 x Power Cable 

-4-

ill 

/,\ 

ill 

This symbol is used to alert the user to important 

operating or maintenance instructions. 

The Lightning bolt triangle is used to alert the user 

to the risk of electric shock. 

SAFETY 

1.  It is important to read these instructions, and to follow them. 

2. Keep this instruction manual in an accessible place. 

3. Clean only with a dry cloth. Cleaning fluids may effect the equipment. 

4.  Do not block any ventilation openings.  Install in accordance with the 

manufacturer's instructions. 

5.  Do not install near any heat sources such as radiators, heating vents, or other 

apparatus that produces heat. 

6. WARNING - THIS APPARATUS MUST BE EARTHED/ GROUNDED. 

7. Only power cords with the correct power connector may be used to maintain 

safety. Cables incorporating the UK 13A fused plug, Schuko with earthing 

contacts or UL approved "grounding type" are acceptable. These must be 

plugged into power outlets which provide a protective earth. 

8. Refer all servicing to qualified personnel. Servicing is required when the 

apparatus has been damaged in any way, such as a power supply cord or 

plug is damaged,  liquid has been spilled or objects have fallen into the 

apparatus, the apparatus has been exposed to any rain or moisture, does not 

operate normally or has been dropped. 

9.  WARNING  To reduce risk of fire or electric shock, do not expose this 

apparatus to rain or moisture. The apparatus shall not be exposed to dripping 

or splashing and no objects filled with liquids, such as vases, shall be placed 

on the apparatus. 

TO PREVENT ELECTRIC SHOCK DO NOT 

REMOVE THE COVER. THERE ARE NO 

USER SERVICEABLE PARTS INSIDE. 

REFER SERVICING TO QUALIFIED 

PERSONNEL. 

Содержание ILD300

Страница 1: ...at produces heat 6 WARNING THIS APPARATUS MUST BE EARTHED GROUNDED 7 Only power cords with the correct power connector may be used to maintain safety Cables incorporating the UK 13A fused plug Schuko...

Страница 2: ...a good appreciation of loop systems the following is a very quick guide to setting up the amplifier All you need is a power source a signal source and a loop See Designing Induction Loops handbook or...

Страница 3: ...control CT LOOP CURRENT Screwdriver adjustable control which sets the which compensates for the frequency dependent effects of metal level of output current delivered into the loop Q SLAVE 1 0 Post co...

Страница 4: ...l cold INPUT 1 _ ____ Signal hot Connection of balanced male XLR for microphone input SLAVE RECORDING DEVICE 1 0 T LOOP a Twisted feeder cable to loop CONNECTOR V b Undo the screw to remove the cover...

Страница 5: ...ackmount tray RM1 U and blanking plate in a and widths as optional extras Remove four rubber feet _The location must provide satisfactory ventilation for the equipment If the unit is installed in an e...

Страница 6: ...n 20m in length Total resistance of loop and feed must be between 0 20 and 1 20 at DC The Designing Induction Loops handbook contains more details on loop and feed cables The correct design and positi...

Страница 7: ...Metal losses tend to increase with frequency and may require the adjustment of the METAL LOSS CORRECTION As a result of this analysis adjust the LOOP CURRENT and set the METAL LOSS CORRECTION on the...

Страница 8: ...ufficiently Check that the LOOP ERROR or OVERHEAT LEDs are not illuminated Ensure the POWER LED is illuminated and not flashing Remove any connection to the SLAVE 1 0 socket Check that the loop cable...

Страница 9: ...ENT or excessive metal loss May require a special loop design to achieve acceptable performance contact Ampetronic for advice Instability or high frequency noise 1 It is possible for the loop cable to...

Страница 10: ...in rear of unit Unplug the loop and AC power supply from amplifier and replace the failed fuse with the spare fuse in AC power input fuse tray Reconnect the AC power supply and switch on If the fuse f...

Страница 11: ...nds on application see Designing induction loops handbook or consult Ampetronic Output Wieland ST17 2 connector Current 7A peak 4 9AR s into 1 2 Voltage 11V peak 7 8V 3 Loop Resistance 0 2n to 1 2n re...

Страница 12: ...Z speaker systems are available WARRANTY This product carries a five year parts and labour warranty from date of shipment from Ampetronic To qualify for the five year warranty the product must be reg...