background image

1. INTRODUCTION

The ILD20 has been designed as a high quality current driver for counter 
systems and small rooms. The unit is easy to install and use, and as a 
counter installation the ILD20 is a complete kit, whilst only suitable wire 
is required for most small rooms.

2. PRELIMINARY INSTALLATION DATA

If the system is installed with the counter loop pad, follow the instructions 
in 2.1.

If the system is to be used with a perimeter loop, follow the instructions 
in 2.2. 

Sections 3, 4 and 5 apply to all installations.

2.1

Fitting the loop coil

The loop coil can be positioned as shown in figure 1, with the larger 
dimension of the coil horizontal. 

If the space for fixing the coil is restricted, then a small portion of the coil 
may be bent over as shown  as in figure 2.

The coil can be fixed to the wall or partition using the adhesive cable 
clips supplied. Position the clips so that the tabs pint towards the centre 
of the coil and locate the tabs or clips so that the coil is held firmly when 
the tabs are bent over. Other clips may be used if preferred.

Important Notes: 

i) The partition or desk must not be made of metal for the system to 
function correctly; if this is a problem please contact Ampetronic Ltd for 
advice.

ii) Do not install the coil in a horizontal plane unless agreed with 
Ampetronic Ltd in advance.

iii) Do not pierce the coil structure with any object.

ILD20

Induction Loop Amplifier

Installation & Commissioning Handbook

Отзывы: