ILD14 HANDBOOK

Box Contents

1 x ILD14 Amplifier
1 x Earth crimp terminal
1 x Spiral mains cable wrap
1 x 2 hole sealing insert
1 x 4 hole sealing insert
1 x T200mAL fuse for 115V ONLY

Handbook Contents

!
!

Overview

!

Quick Start

!

Installation

!

Troubleshooting

!

Technical Specification

!

Warranty

!

Declaration Of Conformity

!

Accessories

Safety

This symbol is used to alert the user to important
 operating or maintenance instructions.
The Lightning bolt triangle is used to alert the user
 to the risk of electric shock.

SAFETY

1. It is important to read these instructions, and to follow them.

2. Keep this instruction manual in an accessible place.

3. Do not install this equipment near any heat sources such as radiators, heating 

vents or other apparatus that produces heat.

4. 

WARNING  THIS APPARATUS MUST BE EARTHED.
 (AC Version only )

5. 

The ILD14 is designed to be permanently connected apparatus and must 
be installed with all applicable installation regulations. A readily accessible 
disconnect device shall be incorporated in the building installation power 

wiring.

6. Mount the ILD14 with the wiring entering from the bottom of the unit if possible. 

Failure of, or incorrect seating of any of the cable glands, may allow liquid or 
moisture to enter the unit.

  

7. Refer all servicing and installation to qualified personnel. 

8. The amplifier generates some heat during normal operation and needs  

adequate ventilation. It should not be fitted in a fully enclosed space.

9. 

Ensure the mains power cable is properly secured and insulated by using 
the spiral wrap supplied. Ensure earth is connected to chassis 
(AC Version only) see installation.

10. Fit the correct sealing insert in each gland according to the type of wire used, 2 

wire, 4 wire or round section. Where all three inputs are used and the Status 
output, you will need to use a multicore type cable consisting of multiple twisted 
pairs having a round outer profile.      

Содержание ILD14

Страница 1: ...permanently connected apparatus and must be installed with all applicable installation regulations Areadily accessible disconnect device shall be incorporated in the building installation power wiring...

Страница 2: ...ut at no extra cost by special order A loop monitor function provides unit status during operation The ILD14 is available in either 230 115V AC or 12VDC Connections are via vibration proof cage clamp...

Страница 3: ...the green compression LED begins to light with a normal signal 7 Adjust each INPUT level in turn Repeat step 6 for each input used 8 Adjust the DRIVE control until the amber Loop Current LED lights at...

Страница 4: ...0V AC Input Version Side View Fixing screw shoulder length 6 3mm 1 4 6 3mm 10mm Mounting Details 82mm 204m m Top View ILD14 I P1 Microphone Amplifier ILD14 I P3 Electret mic ILD14 I P2 Twist together...

Страница 5: ...ing Just before connecting the loop into the amplifier test the loop resistance It must measure between the limits given in theTechnical Specification 3 Connect the input signal s to the appropriate i...

Страница 6: ...that for speaker inputs the drive level is sufficient i e 78mV 20dBu No Drive current Check loop output connections check that one wire is connected to the output and the other wire to output Check l...

Страница 7: ...t 65mA Silver alloy contacts Inputs Frequency Response Transformer isolated 1500Vac minimum 80Hz 5kHz 1 5dB at low level measured floating input as loop current with no metal loss correction Input 1 1...

Страница 8: ...hen it is installed Manufacturer Ampetronic Ltd Northern Road Newark Nottinghamshire NG24 2ET United Kingdom Declares that the product Description Induction Loop Driver Type name ILD14 Conforms to the...

Отзывы: