CLS2 Installation Handbook

 

Handbook Contents 

 

Safety 

 

Introduction 

 

Block diagram 

 

Overview 

 

Connections 

 

Installation 

 

Troubleshooting 

 

Accessories 

 

Technical Specifications 

 

Warranty 

 

Declaration Of Conformity 

Box Contents 

1 x CLS2 
1 x ‘Installation Handbook’ 
1 x Deaf logo 
1 x P-clip, nut & washer 
 
 
 
 
 

 

 

 This symbol is used to alert the user to important 
 operating or maintenance instructions. 
 

 The Lightning bolt triangle is used to alert the user 
 to the risk of electric shock. 
 

SAFETY 

1. 

It is important to read these instructions, and to follow them. 

2. 

Keep this instruction manual in an accessible place. 

3. 

Clean only with a dry cloth. Cleaning fluids may affect the equipment. 

4. 

Do not install this equipment near any heat sources such as radiators, heating vents 

or other apparatus that produces heat. 

5. 

 

WARNING – THIS APPARATUS MUST BE EARTHED / GROUNDED. 

6. 

Only power cords with the correct power connector may be used to maintain safety. 
Cables incorporating the UK 13A fused plug, Schuko with earthing contacts and UL 
approved “grounding type” are acceptable. These must be plugged into power outlets 
which provide a protective earth. 

7. 

Refer all servicing to qualified personnel. Servicing is required when the apparatus 
has been damaged in any way, such as a power supply cord or plug is damaged, 
liquid has been spilled or objects have fallen into the apparatus, the apparatus has 
been exposed to any rain or moisture, does not operate normally or has been 
dropped. 

8. 

 

WARNING – To reduce the risk of fire or electric shock, do not expose this 
apparatus to rain or moisture. The apparatus shall not be exposed to dripping 
or splashing and no objects filled with liquids, such as vases, shall be placed 
on the apparatus.

 

 

TO PREVENT ELECTRIC SHOCK DO NOT REMOVE THE 
COVER. THERE ARE NO USER SERVICEABLE PARTS 
INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL

.

 

Содержание CLS2

Страница 1: ...UST BE EARTHED GROUNDED 6 Only power cords with the correct power connector may be used to maintain safety Cables incorporating the UK 13A fused plug Schuko with earthing contacts and UL approved grou...

Страница 2: ...within the amplifier case and cables are brought into the unit through 20mm knock out holes on the top bottom or back face of the amplifier All adjustments are made within the amplifier case reducing...

Страница 3: ...switch 12V Phantom MLC 3dB thermal limit Over temp mute Mixer AGC Output stage Loop output Current LED Current control Rectification smoothing 30VA transformer 230V pri 9 0 9V sec Mains input Power LE...

Страница 4: ...OVERVIEW Mounting and Cable entry shown with lid removed Knock outs Knock outs Knock outs Mounting holes 5 X 10mm Mounting holes 5 X 10mm Detachable earth lead MUST be re connected before lid is secur...

Страница 5: ...in off position Phantom enable shown in off position Input gain controls Input gain controls Input gain controls Metal loss correction Metal loss correction Metal loss correction Output current contr...

Страница 6: ...mm Signal Inputs Screen Signal cold Signal hot INPUT 2 MIC Balanced Microphone Global Phantom for inputs 1 and 2 Phantom off Phantom on Balanced Microphone Balanced line Signal cold Signal hot Screen...

Страница 7: ...d 12Vdc for external modules screen return Alert 1 5 24VAC or DC If dc observe polarity Alert 2 Normally open contacts ALERT INPUTS 100V Line Mono Low Impedance speaker Stereo Low Impedance Speaker Le...

Страница 8: ...Heatsink can be hot Route cables away from heatsink Loop Twist feed wires together LOOP OUTPUT Fuse cover Live Neutral Earth AC POWER Washer P clip Nut 30m 6mm Sheathed 3 core cable Separate cables C...

Страница 9: ...h is secured by two Phillips No 2 screws The unit may also be used free standing The location must provide adequate ventilation for the unit If the unit is installed in an enclosed environment suffici...

Страница 10: ...have already been installed to the site where the unit will be mounted and that the AC power feed is isolated 1 Mount the unit in its intended position 2 Route cables conduits to appropriate knock out...

Страница 11: ...ly have been carried out before turning supply on 7 Turn on AC power feed The POWER and AGC LEDs will illuminate If the LEDs fail to illuminate consult the Troubleshooting section The AGC LED will go...

Страница 12: ...factory performance 12 Repeat the above procedure for each input used When adjusting each input make sure the signals are removed from the other inputs This ensures that all signals are set to equival...

Страница 13: ...infinitely high reading i e no connection at all Any reading indicates a failure of the loop cable insulation and you will need to either repair or replace the loop cable 2 Instability can be caused...

Страница 14: ...mpedance unbalanced 2 wire circuit cables in close proximity to the loop cable Separate the loop cables to reduce the effect 4 Remote and apparently unconnected PA systems can sometimes pick up loop s...

Страница 15: ...tted into terminal block SIGNAL PROCESSING AGC Automatic Gain control Dynamic range 36dB Output level 6dBu 1dB Attack 3 8ms Decay 1 7s MLC Metal loss correction Frequency response adjustment From flat...

Страница 16: ...nstructions in this handbook are not followed correctly or if the unit is misused in any way DECLARATION OF CONFORMITY Manufacturer Ampetronic Ltd Northern Road Newark Nottinghamshire NG24 2ET United...

Отзывы: