CLS1 Installation Handbook

 

Handbook Contents 

  Safety 

  Introduction 

  Block diagram 

  Overview 

  Connections 

  Installation 

  Troubleshooting 

  Accessories 

  Technical Specifications 

  Warranty 

  Declaration Of Conformity 

Box Contents 

1 x CLS1 

1 x ‘Installation Handbook’ 

1 x Deaf logo 

1 x P-clip, nut & washer 

 

 

 

 

 

 

 

 This symbol is used to alert the user to important 

 operating or maintenance instructions. 

 

 The Lightning bolt triangle is used to alert the user 

 to the risk of electric shock. 

 

SAFETY 

1.  It is important to read these instructions, and to follow them. 
2.  Keep this instruction manual in an accessible place. 
3.  Clean only with a dry cloth. Cleaning fluids may affect the equipment. 
4.  Do not install this equipment near any heat sources such as radiators, heating vents 

or other apparatus that produces heat. 

5. 

 

WARNING – THIS APPARATUS MUST BE EARTHED / GROUNDED. 

6.  Only power cords with the correct power connector may be used to maintain safety. 

Cables incorporating the UK 13A fused plug, Schuko with earthing contacts and UL 

approved “grounding type” are acceptable. These must be plugged into power outlets 

which provide a protective earth. 

7.  Refer all servicing to qualified personnel. Servicing is required when the apparatus 

has been damaged in any way, such as a power supply cord or plug is damaged, 

liquid has been spilled or objects have fallen into the apparatus, the apparatus has 

been exposed to any rain or moisture, does not operate normally or has been 

dropped. 

8.   

WARNING – To reduce the risk of fire or electric shock, do not expose this 

apparatus to rain or moisture. The apparatus shall not be exposed to dripping 

or splashing and no objects filled with liquids, such as vases, shall be placed 

on the apparatus.

 

 

 

   

 

TO PREVENT ELECTRIC SHOCK DO NOT REMOVE THE 

COVER. THERE ARE NO USER SERVICEABLE PARTS 

INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL

.

 

ATTENTION: RISQUE DE CHOCS ELECTRIQUE NE PAS OUVRIR 

 

Содержание CLS1

Страница 1: ...Only power cords with the correct power connector may be used to maintain safety Cables incorporating the UK 13A fused plug Schuko with earthing contacts and UL approved grounding type are acceptable...

Страница 2: ...ith a hinged and detachable lid which is secured by two PH2 screws All connections are made via screw terminal blocks within the amplifier case and cables are brought into the unit through 20mm knock...

Страница 3: ...AGC LED MIC Line switch 12V Phantom MLC 3dB thermal limit Over temp mute Mixer AGC Output stage Loop output Current LED Current control Rectification smoothing 30VA transformer 230V pri 9 0 9V sec Ma...

Страница 4: ...RVIEW Mounting and Cable entry shown with lid removed CLS1 Knock outs Knock outs Knock outs Mounting holes 5 X 10mm Mounting holes 5 X 10mm Detachable earth lead MUST be re connected before lid is sec...

Страница 5: ...tails see next section Live Input 1 Mic Line Input 2 Line Neutral Earth AC power input Loop output Input 3 100V Line speaker Mic Line switch Phantom enable shown in off position Input gain controls Ou...

Страница 6: ...ced Microphone Balanced line Signal cold Signal hot Screen Signal cold Signal hot Screen Unbalanced line Signal Screen Global Phantom Note Phantom automatically disabled in line mode INPUT 1 MIC LINE...

Страница 7: ...oop Twist feed wires together LOOP OUTPUT 100V Line Mono Low Impedance speaker Stereo Low Impedance Speaker Left Right INPUT 3 100V LINE SPEAKER either channel can be used Signal hot Signal cold Signa...

Страница 8: ...8 Fuse cover Live Neutral Earth AC POWER Washer P clip Nut 30m 6mm Sheathed 3 core cable Separate cables Cable tie...

Страница 9: ...h is secured by two Phillips No 2 screws The unit may also be used free standing The location must provide adequate ventilation for the unit If the unit is installed in an enclosed environment suffici...

Страница 10: ...ables have already been installed to the site where the unit will be mounted and that the AC power feed is isolated 1 Mount the unit in its intended position 2 Route cables conduits to appropriate kno...

Страница 11: ...minate If the LEDs fail to illuminate consult the Troubleshooting section The AGC LED will go out after a few seconds 8 Select one input and apply a suitable audio signal ideally the FSM test signal C...

Страница 12: ...ach input make sure the signals are removed from the other inputs This ensures that all signals are set to equivalent loudness and drive the AGC properly 13 Finally refit the lid and earth wire Secure...

Страница 13: ...g indicates a failure of the loop cable insulation and you will need to either repair or replace the loop cable 2 Instability can be caused by using poor quality signal cables long unbalanced 2 wire s...

Страница 14: ...cuit cables in close proximity to the loop cable Separate the loop cables to reduce the effect 4 Remote and apparently unconnected PA systems can sometimes pick up loop signals This is usually because...

Страница 15: ...ain control Dynamic range 36dB Output level 6dBu 1dB Attack 3 8ms Decay 1 7s MLC Metal loss correction Frequency response adjustment From flat to 3dB octave centred around 1kHz OUTPUTS Loop Output Max...

Страница 16: ...n this handbook are not followed correctly or if the unit is misused in any way DECLARATION OF CONFORMITY Manufacturer Ampetronic Ltd Unit 2 Trentside Business Village Farndon Road Newark NG24 4XB Dec...