Ampetronic AMP-ILD100 Скачать руководство пользователя страница 1

1. It is important to read these instructions, and to follow them.
2. Keep this instruction manual in an accessible place.
3. Clean only with a dry cloth. Cleaning fluids may effect the equipment.
4. Do not cover or obstruct ventilation of this unit. Install in accordance with the 

manufacturer’s instructions.

5. Do not install near any heat sources such as radiators, heating vents, or other 

apparatus that produces heat.

6. Refer all servicing to qualified personnel. Servicing is required when the 

apparatus has been damaged in any way, such as a power supply cord or 
plug is damaged, liquid has been spilled or objects have fallen into the 
apparatus, the apparatus has been exposed to any rain or moisture, does not 
operate normally or has been dropped.

7. WARNING - To reduce risk of fire or electric shock, do not expose this 

apparatus to rain or moisture. The apparatus shall not be exposed to dripping 
or splashing and no objects filled with liquids, such as vases, shall be placed 
on the apparatus.

TO PREVENT ELECTRIC SHOCK DO NOT 
REMOVE THE COVER. THERE ARE NO 
USER SERVICEABLE PARTS INSIDE. 
REFER SERVICING TO QUALIFIED 
PERSONNEL.

        

ILD100 HANDBOOK

Box Contents

1 x ILD100
1 x Installation & Commissioning 

Handbook

1 x Power Cable

Handbook Contents

!
!

Introduction

!

Quick Start

!

Overview

!

Installation

!

Troubleshooting

!

Accessories

!

Technical Specification

!

Warranty

!

Declaration of Conformity

Safety

The Lightning bolt triangle is used to alert the user
 to the risk of electric shock.

SAFETY:

RISK OF ELECTRIC SHOCK 

DO NOT OPEN 

CAUTION

This symbol is used to alert the user to important
 operating or maintenance instructions.

Содержание AMP-ILD100

Страница 1: ...s not operate normally or has been dropped 7 WARNING To reduce risk of fire or electric shock do not expose this apparatus to rain or moisture The apparatus shall not be exposed to dripping or splashi...

Страница 2: ...field produced inside the loop area using a receiving device e g Ampetronic ILR3 or examine the performance in more detail with a suitable field strength meter 10 Adjust the TONE control to achieve a...

Страница 3: ...t current delivered to the loop TONE Screwdriver adjustable control allowing adjustment to the system frequency response Compression LED shows input signal has reached the compression point Loop curre...

Страница 4: ...P 1 LINE I P MIC 2 gain TONE Compressor DRIVE Output LOOP Compression LED Loop Current LED MICROPHONE INPUTS MODE SWITCH LINE gain 1 2 3 OVERVIEW cont d MICROPHONE inputs 3 5mm mono jack connectors L...

Страница 5: ...ld be less than 0 8 W The cable from the loop to the ILD100 output terminals MUST be a twisted pair If this is longer than 10 metres contact Ampetronic Tools Equipment Small hand tools including a wir...

Страница 6: ...le length The above mentioned adaptor converts the input to a balanced line which can be extended to longer distances Line Input A twin phono input is fitted to the unit allowing a direct connection t...

Страница 7: ...with an ILR3 or an FSM Setting of input controls Optimising Compression VOX levels In order to obtain the greatest possible dynamic control range from the compressor it is now necessary to establish...

Страница 8: ...ect The VOX threshold is at the onset of compression and as such is automatically set by the MICROPHONE and LINE controls Switch Position signal is higher than signal is lower than VOX threshold VOX t...

Страница 9: ...which may sound like high frequency noise buzz or whistling The results of this type of fault are likely to cause the unit to overheat This fault is easy to determine Simply disconnect the loop cable...

Страница 10: ...ect such interference Check entire sound system for evidence of loop signal and trace source of pick up 4 Under certain circumstances the loop signal may appear as jagged lines or hum bars on a CCTV p...

Страница 11: ...n Input Impedance 8kW section for details 0 Sensitivity 60dBu 775uV RMS Ambient temperature 0C to 35 C for full output Relative Humidity 90 Overload 12dBu 200mV RMS LINE Input Twin RCA phono inputs In...

Страница 12: ...re not followed correctly or if the unit is misused in any way www ampetronic com Manufacturer Ampetronic Ltd Northern Road Newark Nottinghamshire NG24 2ET United Kingdom Declares that the product Des...

Отзывы: