Fire
Finder
Страница 1: ...F ireF inder ...
Страница 2: ... LCD DISPLAY OF DESCRIPTION TYPE ADDRESS DATE TIME AND NUMBER OF DISABLES 3 SOUNDER SILENCE FIRE LED STEADY IF NECESSARY PRESS TO SILENCE SOUNDERS INDICATOR WILL TURN ON 3 RESET ALARMS PRESS TO RESET ALL ALARMS DESCRIPTION DATE TIME LOOP No SENSOR No STATUS ALARM SENSOR ALARMS 1 OF xx TYPE LOOP No SENSOR No STATUS DIS DESCRIPTION DATE TIME SENSOR DISABLES 1 OF xx TYPE FIRE SOUNDER SILENCE EVACUATE...
Страница 3: ...ions TB1 Error Bookmark not defined 5 10 2 Auxiliary 27 Volt Power TB2 Error Bookmark not defined 5 10 3 Bell Sounder Monitored Outputs TB3 TB5 Error Bookmark not defined 5 10 4 Relay Output Connections TB6 TB10 Error Bookmark not defined 5 11 Main Board BRD86MBA Error Bookmark not defined 5 12 Front Panel Board 302 690 Error Bookmark not defined 5 13 Main CPU BRD85CPU Error Bookmark not defined 5...
Страница 4: ... Display Repeater Panel 302 7200 Error Bookmark not defined 8 FireFinder Operation 3 8 1 The Control Panel 3 9 Functions And Menus 7 9 1 The Default LCD Display 7 9 2 Accessing Functions and Menus 7 9 3 Function Menu and Access Levels 7 9 3 1 Forgotten Passwords 7 10 The Main Menu 8 10 1 Status Menu 8 10 2 Testing Menu 10 10 3 Sounders 10 11 Main Functions 11 11 1 Setting the Function Date Facilit...
Страница 5: ...16 Troubleshooting Chart Error Bookmark not defined 17 Address Setting Error Bookmark not defined 18 Glossary of Terms 21 19 Definitions 22 20 Qick Reference Guides 23 ...
Страница 6: ...r the purpose of carrying out work on or with AMPAC supplied equipment and may not be used for any other purpose whatsoever 2 The Trader shall disclose Proprietary Information received by AMPAC under this Agreement to persons within its organisation only if such persons are legally bound in writing to protect the confidentiality of such Proprietary Information 3 The undertakings and obligations of...
Страница 7: ...t compromised in any way installation staff and operators should Be qualified and trained for the task they undertake Be familiar with the contents of this manual prior to the installation commissioning or operation of a FireFinder control system Observe anti static pre cautions at all times and Be aware that if a problem is encountered or there is any doubt with respect to the operational paramet...
Страница 8: ...bove the button will be illuminated steady indicating that the sounders have been silenced and a sounder resound is available If a manual evacuate or manual alert condition is present when the Sounder Silence button is pressed these conditions will remain visible indicating the conditions are still present for resounding A new Fire Alarm manual evacuate or manual alert will resound all the previou...
Страница 9: ...nditions will remain present but the associated Bells and Sounders will turn off These Bells and Sounders will reactivate when the Sounder Disable button is pressed a second time for re enablement POWER ON POWER ON Green This LED will be illuminated when power is connected to the FACP and switched on PRE ALARM PRE ALARM Red This LED will be illuminated when a sensor detector is in the pre alarm st...
Страница 10: ...ing the LOOP button press the DEVICE button to enter the sensor number for the device you wish to interrogate ZONE ZONE Press this button followed by a number e g ZONE 4 to select the required zone DISPLAY DISPLAY Press this button after selecting the Zone number or the Loop and Sensor numbers to display the status of the device 8 WXYZ THE ALPHA NUMERIC BUTTONS These buttons are used to navigate a...
Страница 11: ...el 1 Sensor Mode ALM 000 Number of Alarms present PALM 000 Number of Pre alarms present FAULT 000 Number of Faults present DIS 000 Number of Disables present Customer defined text Figure 2 LCD Default Screen This screen can be configured with the servicing companies name and phone number It also displays the current date time and if the system is normal no faults and fire alarms If there are any f...
Страница 12: ...event unauthorised changes to the panel s configuration 4 3 Function Menu and Access Levels Three levels of ACCESS are available Level 1 has access to MENU only while Password protected Levels 2 and 3 access MENU and FUNCTION as listed below Also see the Quick Reference Guide Section 26 Level II Allows access to Date Enter the Day Month and Year 4 digit year Time Enter the hours and minutes 24 hou...
Страница 13: ...the system components and settings listed below can be interrogated Press Loops Enter the loop number and it will display its status Modules If pressed the following sub menu will be displayed Slave Power Supply Brigade Outputs External LED Mimic E g Pressing Power Supply This menu item will display the charger voltage whether or not the power supply is in fault if Mains is available and if the ba...
Страница 14: ...mic Modules then NP number then ENTER then External LED Mimic number then ENTER System Is pressed to access SYSTEM STATUS for a network panel Figure 8 Display System Status Apollo Loop 1 TYPE APOLLO LOOP NO 1 VER 6 1 NP 1 MOD 4 STAT NORMAL REMOTE MODULE STATUS AC 2S ALM 000 PALM 000 FLT 000 DIS 000 DISPLAY NETWORK POINTS 0 STATUS 1 POWER SUPPLY 2 BRIGADE SELECT NO AC 2S ALM 000 PALM 000 FLT 000 DI...
Страница 15: ...ult State or a conventional zone to a simulated Fault State Once the above tests have been completed the TEST COMPLETE screen will appear Each ALARM and FAULT that was detected can be viewed by scrolling through them using the NEXT and PREVIOUS buttons Lamp Test Will flash the LED s in sequence on the front panel and illuminate the various segments on the LCD display 5 3 Sounders Press To select S...
Страница 16: ...on Daynight Facility Press The DAY NIGHT SETTINGS screen will appear Press To enter the DAY ON time then ENTER and To enter the NIGHT ON time then ENTER To enter this mode the function must be ENABLED press Re pressing will DISABLE the DAYNIGHT function 6 4 Function Logs Facility Press And the EVENT LOG MENU will appear The LOGS MENU function allows the operator to select and view the events of al...
Страница 17: ...then the next highest Zone number to be tested EG 2 TO 7 then ENTER The TEST MODE LED will be illuminated for the duration of the test and the test will run until the operator RESETS the system SENSOR WALK TEST MENU This screen requires the operator to select a Zone and then a Sensor or number of Sensors using the TO key to be tested then pressing ENTER to start the test The TEST MODE LED will be ...
Страница 18: ...trol Output Selected Same sequences as above for inputs but substitute outputs for Inputs Remove All Manual Control Selected Globally removes all manual control 6 7 Function Passwords Press While in the Main Functions menu if your password gives you access to display the Password Menu Figure 13 The Password Menu Press Add Password Enter the new password then press ENTER The password is always a 4 ...
Страница 19: ...l Zone Programming Press Zone Key in the zone number and enter or change the description DESC by pressing the numeric buttons multiple times to access characters while at the same time using the buttons to move the flashing underline or cursor Figure 15 Zone Descriptions Type Programming Press to move to the TYPE field or edit the information Press to move between fields use the reciprocal button ...
Страница 20: ...ENTER to confirm the entries and or changes 6 8 2 Device Programming Press DEVICE Use these keys to EDIT and move through wording numbering Use these keys to MOVE between fields i e DESC TYPE and NEXT PARAMETER SETTING Screen Enter the Loop and Sensor number then scroll through the following screens Press or Press To EDIT or to DELETE EDIT LxSx DESCRIPTION AND TYPE STRING After each step press EDI...
Страница 21: ... prompts in the same way as above Edit or delete an INPUT in a panel or a loop Screen PROGRAM MENU SELECTING AN INPUT IN A PANEL ON A LOOP i PANEL LOOP OR REMOVE i LOOP Select one of the above Select LOOP NO then ENTER ii I O MODULE ii SENSOR Select I O MODULE NO then ENTER Select SENSOR NO then ENTER iii IINPUT iii INPUT Select I P NO then ENTER Select INPUT NO then ENTER key iv EDIT DELETE DESC ...
Страница 22: ...ng Entering presents the PROGRAMMING MENU Select the appropriate programming screen from those listed on the screen as seen below and select enter to accept the changes or skip to resolve the changes manually Figure 21 Resolving Extra Modules or Devices 0 ADD EXTRA MODULES 1 ADD EXTRA DEVICES 2 DEVICE TYPE MISMATCH 3 MODE MISMATCH SELECT NO AC 3S ALM 000 PALM 000 FLT 000 DIS 000 PROGRAMMING MENU 0...
Страница 23: ...formation and fault or disablement information is available via the previous and next keys After 30 seconds if no key is pressed the top section of the display will revert to displaying the first zone in alarm If there are any faults or fire alarms the LCD will display the device in question in the top screen if multiple detectors or zones are not in their normal state the PREVIOUS and or NEXT but...
Страница 24: ...button if you wish to disable a sensor 18 Press the DEVICE DISABLE ENABLE button again to enable a sensor For Multiple Devices LOOP DEVICE TO DISPLAY DEVICE DISABLE ENABLE 2 DEF 7 TUV 4 JKL Figure 22 LCD Screen with 4 Devices in Alarm ZONE 19 From the default display press ZONE 20 Press the button for the zone number 21 Press the TO button if you wish to access a range of zones 22 Press the DISPLA...
Страница 25: ...er is designed and manufactured by AMPAC TECHNOLOGIES PTY LTD 7 Ledgar Rd Balcatta WA 6021 Western Australia PH 61 8 9242 3333 FAX 61 8 9242 3334 Manufactured to Certificate of Compliance Number Equipment Serial Number Date of Manufacture HEAD OFFICE ...
Страница 26: ...LDING EARTH EOL END OF LINE FDS FIRE DETECTION SYSTEM FACP FIRE ALARM CONTROL PANEL FLT FAULT GND GROUND 0 VOLTS NOT EARTH I O INPUT OUTPUT LCD LIQUID CRYSTAL DISPLAY MAF MASTER ALARM FACILITY MCP MANUAL CALL POINT MOV METAL OXIDE VARISTOR TRANSIENT PROTECTION NIC NETWORK INTERFACE CARD N C NORMALLY CLOSED RELAY CONTACTS N O NORMALLY OPEN RELAY CONTACTS N W NETWORK PCB PRINTED CIRCUIT BOARDS P S P...
Страница 27: ... detection system using a dedicated circuit for each alarm zone Distributed system a fire alarm and detection system where sections of the control and indicating equipment are remotely located from the FACP or where sub indicator panel s communicate with a main FACP Field connections are connections made to FACP or ancillary equipment during installation Fire alarm system an arrangement of compone...
Страница 28: ... THE SELECTED TEST FIELDS ALARM TEST ALARM FIELDS OUTPUTS OUTPUT No INPUT INPUT No FAULT TEST FAULT FIELDS LAMP TEST FIELDS ZONE ZONE No SENSOR LOOP SENSOR No I O NETWORK POINTS REMOTE SLAVE MODULES REMOTE EXT LED MIMIC MODULES SYSTEM AVALUES ANALOGUE VALUE OF DET SELECT LOOP NO THEN ENTER ZONE ZONE No SENSOR LOOP SENSOR No MENU KEY FUNCTION KEY TO ENTER MENU TO FUNCTION MENU SPACE 0 DEF 2 MENU AB...
Страница 29: ...VE ALL MANUAL I O CONTROL RETURN ALL MANUAL INPUTS AND OUTPUTS TO ORIGINAL STATE LEVEL 3 FUNCTIONS FUNCTION MENU OPTIONS FUNCTION KEY TO ENTER FUNCTION FIELD ENTER PASSWORD DATE DD MM YYYY TIME HH MM DAY NIGHT SETTINGS SET ON OFF FIELDS DAY TIME HH MM ENABLE LOGS LEVEL 3 FUNCTIONS NIGHT TIME HH MM ALARM ALARM LOG SHOW OPTIONS VIEW BY ENTRY NO VIEW BY DATE PRINT ENTRY PRINT TO PANEL PRINTER IF FITT...