Amit RRU-WEM/1158 Скачать руководство пользователя страница 1

 

rru-wem1158_g_en_100 

RRU-WEM/1158 

 
 

WTB / Ethernet / MVB gateway 

Operation manual 

Version 1.00 

 

Содержание RRU-WEM/1158

Страница 1: ...rru wem1158_g_en_100 RRU WEM 1158 WTB Ethernet MVB gateway Operation manual Version 1 00...

Страница 2: ...pages must be copied without any changes 2 All redistributed copies must retain the AMiT spol s r o copyright notice and any other notices contained in the documentation 3 This document must not be d...

Страница 3: ...Communication lines 19 8 1 WTB 19 8 1 1 WTB line state indication 20 8 2 Ethernet 21 8 2 1 Ethernet line state indication 22 8 3 MVB 23 8 3 1 MVB line state indication 24 9 Indications and settings 2...

Страница 4: ...em1158_g_en_100 pdf Revision Date Author of change Changes 100 1 08 2017 koch J New document Related documentation 1 WTB Ethernet MVB Gateway Programming manual file rru wem1158_1_ms_en_xxx pdf 2 Appl...

Страница 5: ...Definition of used abbreviations Bus Administrator Electric Middle Distance Medium Attachment Unit Multifunction Vehicle Bus Message Data Process Data To Be Defined Train Communication Network Wire Tr...

Страница 6: ...rection 1 and 2 are disconnected Terminating resistors are connected in both directions Intermediate Setting The node in this state is physically connected in the middle of WTB line The main MAU chann...

Страница 7: ...led WTB interface and one doubled MVB interface WTB gateway RRU WEM 1158 contains working Ethernet line connector M12 1 WTB interface doubled line 1 MVB interface double line 1 Ethernet 100 Mbps conne...

Страница 8: ...1 Data transmission rate 100 Mbps Recommended cabling STP CAT5 Maximum segment length 100 m Operation indication LED LNK and ACT Connection point M12 connector according to IEC 61375 3 4 2012 Ed 1 0 D...

Страница 9: ...el is made from aluminium alloy without detail specifying of additives composition Surface is naturally anodized 2 After all cable connectors are connected 3 1 HP horizontal pitch 0 2 inch 5 08 mm 1U...

Страница 10: ...on max 10 ms Class S2 according to Chapter 3 1 1 2 of EN 50155 2007 For supply voltage switching are permissible conditions of C1 and C2 Class The device is not classified according to EN 50128 2011 R...

Страница 11: ...RRU WEM 1158 11 34 rru wem1158_g_en_100 4 1 Dimensions 141 9 138 8 168 5 171 0 203 7 128 4 32 7 127 0 122 4 RRU WEM 1158 110 V Fig 1 Physical dimensions of WTB gateway...

Страница 12: ...symbol is recommended for RRU WEM 1158 gateway RRU WEM 1158 X2 Ethernet M12 X3 WTB A1 D sub DE 9 M X4 WTB A2 D sub DE 9 F X5 WTB B1 D sub DE 9 M X7 MVB M1 D sub DE 9 M X8 MVB M2 D sub DE 9 F X6 WTB B...

Страница 13: ...FPGA Power supply DDR2 WTB interface Ethrenet interface 5 V ss X2 X3 X4 X5 X6 X7 X8 WTB A1 WTB A2 WTB B1 WTB B2 MVB M1 MVB M2 Ethernet 2 5 V ss 1 8 V ss 1 2 V ss MVB interface X1 Power Vcc Power supp...

Страница 14: ...tion POWER 110 V DC 0 1 A Power supply voltage WEIGHT m mm kg Weight netto TEST OK xx Routine testing result HiPot HiPot OK HiPot test result DATE dd mm yyyy Production date in day month year format L...

Страница 15: ...ru wem1158_g_en_100 TYPE S N MAC FW POWER WEIGHT TEST HiPot DATE RRU WEM 1158 AA00000 00 09 54 FF FF FF APP 1 00 LDR 1 00 110 V DC 0 1 A 1 56 kg OK AM HiPot OK 01 04 2015 Fig 5 Location of type label...

Страница 16: ...rostatic discharge immunity test Complies EN 61000 4 3 2006 Electromagnetic compatibility EMC Part 4 3 Testing and measurement techniques Radiated radio frequency electromagnetic field immunity test C...

Страница 17: ...dips short interruptions and voltage variations on d c input power port immunity tests S2 C1 C2 EN 60068 2 1 2007 Environmental testing Part 2 1 Tests Test A Cold Complies EN 60068 2 2 2007 Environmen...

Страница 18: ...V DC from vehicle onboard power network 7 1 Powering from DC network Power supply is connected to X1 WAGO 769 663 plug Fig 6 Power supply connector location Connector WAGO 769 663 003 000 PIN Signal D...

Страница 19: ...ors Connectors are fitted with M3 threaded nuts that prevents the cable falling off due to vibrations or to be broken away Fig 7 Location of WTB line connectors Connector type D sub DE 9 plug Connecto...

Страница 20: ...tate of line A Six LEDs in WTB B area indicate the state of line B and the remaining four LEDs indicate the node state Following table describes meaning of the individual LEDs Fig 8 LEDs front panel d...

Страница 21: ...network connection Ethernet interface is fitted with M12 connector according to IEC 61375 3 4 2014 Fig 9 Location of Ethernet line connector M12 type connector according to EN 61375 3 4 2014 1 Connec...

Страница 22: ...ication Indication of Ethernet line state is provided by two LEDs located above the X2 connector Fig 10 Front panel LEDs detail Ethernet LED Colour Description LNK Green Gateway connection to Ethernet...

Страница 23: ...s used Fig 11 Location of MVB connectors Connector type D sub DE 9 plug Connector PIN Signal Description X6 1 A Data_P A line positive wire 2 A Data_N A line negative wire 3 TxE optional Not connected...

Страница 24: ...e WTB gateway is delivered in class 5 design without the Bus Administrator functionality according to EN 61375 1 2012 standard chapter 3 2 2 8 3 1 MVB line state indication State of MVB line is indica...

Страница 25: ...faultless Following cases can occur when gateway is in Error status WTB configuration is missing or cannot be read Invalid Ethernet configuration Application start failed Occurrence of another error i...

Страница 26: ...the factory setting press and hold the RSTR button while gateway starts up First the S1 LED goes ON and after ca 5 sec starts to blink Release the button when S1 LED starts to blink After setting of...

Страница 27: ...xated by thread glue 127 122 4x A A Fig 14 Mounting into 19 subrack If needed WTB gateway can be mounted in a suitable frame In case of mounting into the frame four screws with M3 5 thread are used no...

Страница 28: ...least 70 mm in front of WTB gateway for attaching the cables It is very important to ensure that ambient temperature does not exceed the allowed limits At the same time it is necessary to ensure that...

Страница 29: ...TB gateway power supply connector must be connected with local installation earthing terminal Minimum cross section of supplying conductors must be at least 0 75 mm2 All cabling must be carefully tied...

Страница 30: ...testing protocol 1 11 3 Connectors 21038821405 Crimping M12 cable connector D coding 09670007576 Crimping contacts to 21038821405 for AWG 24 28 CAN 09F MC A WTB and MVB line connector counterpart D s...

Страница 31: ...on the box contains following information values are illustrative Item Description TYPE Unit type NETTO Weight of separate unit BRUTTO Weight of packaged unit QTY Quantity of units inside package S N...

Страница 32: ...e can be stored in any position If boxes are stockpiled weight acting on the top side of the box must not exceed 10 kg Load must be evenly spread over the entire upper side of the box Unpacked device...

Страница 33: ...WTB gateway is used time to time it is necessary to clean the dust from the inside of the equipment The WTB gateway can be cleaned in cut off state and disassembled by dry paintbrush or fine brush al...

Страница 34: ...disposal The disposal of electronics is subject to the regulations on handling electrical waste Unit must not be disposed together with common public waste It must be delivered to places specified fo...

Отзывы: