RRAS-MCT/A
9/19
rras-mcta_g_en_100
3. Compliance assessment
The equipment meets the claims of Czech government decree NV616/2006; the
compliance assessment has been performed in accordance with harmonized
standard EN 50121-3-2:2006.
Tested in accordance
with standard
Type of test
Classification
EN 55011:2007
Radio disturbance
complies
EN 61000-3-3:2008
EMC
– Limitations of voltage changes,
voltage fluctuations and flicker in public
low-voltage supply systems
complies
EN 61000-4-3:2006
EMC
– Part 4-3: Radiated, radio-
frequency, electromagnetic field
immunity test,
800 MHz to 1000 MHz
20 V/m
EN 61000-4-3:2006
EMC
– Part 4-3: Radiated, radio-
frequency, electromagnetic field
immunity test, 1000 MHz to 2100 MHz
10 V/m
EN 61000-4-3:2006
EMC
– Part 4-3: Radiated, radio-
frequency, electromagnetic field
immunity test, 2100 MHz to 2500 MHz
5 V/m
EN 61000-4-4:2004
Electrical fast transient/burst immunity
test
– power supply
4 kV *)
EN 61000-4-4:2004
EMC
– Electrical fast transient immunity
test
– inputs
2 kV *)
EN 61000-4-5:2006
EMC
– Surge immunity test, RS485
4 kV *)
EN 61000-4-5:2006
EMC
– Surge immunity test, power
supply
4 kV *)
EN 61000-4-6:2009
Immunity to induced disturbances,
induced by radio-frequency fields
10 V
EN 61000-4-11:2004
Voltage dips, short interruptions and
voltage variations immunity tests
complies
*) Some disturbing noise can be heard in the speaker when disturbances
appear.
3.1. Other tests
This product has been assessed and approved for use in railway applications
according to standards:
EN 50155:2007
Elecronic equipment used on rolling stock.
EN 50121-3-2:2006
Railway applications
– Electromagnetic compatibil-
ity
– Part 3-2: Rolling stock – Apparatus
EN 61373:1999
Railway applications
– Rolling stock equipment –
Shock and vibration tests.
EN 60068-2-1:2007
Environmental testing
– Part 2-1: Test A: Cold.
EN 60068-2-2:2007
Environmental testing
– Part 2-2: Test B: Dry heat.