Amit RRAM-MCT/E2 Скачать руководство пользователя страница 1

 

rram-mcte2_g_en_100 

RRAM-MCT/E2 

 
 

Train audio exchange unit 

according to UIC568 

Operation manual 

Version 1.00 

 

Содержание RRAM-MCT/E2

Страница 1: ...rram mcte2_g_en_100 RRAM MCT E2 Train audio exchange unit according to UIC568 Operation manual Version 1 00...

Страница 2: ...t all pages must be copied without any changes 2 All redistributed copies must retain the AMiT spol s r o copyright notice and any other notices contained in the documentation 3 This document must not...

Страница 3: ...line state indication 15 5 2 Ethernet 16 5 2 1 Ethernet line state indication 17 6 UIC interface 18 6 1 1 UIC line state indication 19 7 Inputs outputs 20 7 1 Audio input 20 7 2 Power audio outputs 2...

Страница 4: ...History of revisions Document name rram mcte2_g_en_100 pdf Author Martin Pol ek Revision Date Changes 100 12 7 2013 New document Related documentation 1 Application Note AP0037 Principles of using Et...

Страница 5: ...dio amplifier two Ethernet interfaces and single M12 interface 1 UIC interface 1 RS485 interface 1 audio input 2 Ethernet interface 2 power audio output Power supply voltage 24 V DC Mounting into pane...

Страница 6: ...on Magnetic holder Handset detection Magnetic contact Number of lines 2 Data transmission rate 100 Mbps Galvanic separation Yes Insulation strength 500 V AC 1 min Connection point M12 connector socket...

Страница 7: ...wnloading by application RRAS Configurator via Ethernet line Equipment is intended to operate up to 1 400 m above the sea level Equipment is designed to meet the Temperature Class TX According to EN 6...

Страница 8: ...RRAM MCT E2 rram mcte2_g_en_100 8 31 2 1 Dimensions 110 mm 140 mm 68 mm 85 mm 149 mm 20 mm 67 mm 108 mm 290 mm 330 mm Obr 1 RRAM MCTE E2 mechanical dimensions...

Страница 9: ...RRAM MCT E2 9 31 rram mcte2_g_en_100 2 2 Design of front panel 2 1 3 4 Obr 2 Design of RRAM MCTE E2 front panel...

Страница 10: ...RRAM MCT E2 rram mcte2_g_en_100 10 31 Legend Description Colour 1 Panel RAL 9005 2 Foil RAL 9005 3 Foil print RAL 9010 4 Illuminated elements of foil print RAL 9010 Colour design...

Страница 11: ...g drawing symbol is recommended for RRAM MCT E2 RRAM MCT E2 X3 ETH M12 X4 UIC7 UIC6 UIC5 UIC4 5 6 7 3 4 8 UIC8 X2 UIC3 UIC2 UIC1 1 2 GND PE 1 2 X1 SPKA SPKA SPKB SPKB Vcc 5 6 7 3 4 9 10 8 GND RS B A E...

Страница 12: ...est 2100 MHz to 2500 MHz 5 V m EN 61000 4 4 2012 Electromagnetic compatibility EMC Part 4 4 Testing and measurement techniques Electrical fast transient burst immunity test power supply 4 kV EN 61000...

Страница 13: ...lications according to standards Tested in accordance with standard Type of test Classificati on EN 50155 2007 Electronic equipment used on rolling stock Complies EN 50121 3 2 2006 Electromagnetic com...

Страница 14: ...nal is internally connected with exchange cover and panel as well as with metal caps of all connectors Connector type WAGO 769 670 Connector Pin Signal Meaning X1 1 PE Unit chassis 2 GND Power supply...

Страница 15: ...e located in X1 connector see chapter 4 Communication line termination is set by SW switch SW state Termination ON ON Connected OFF OFF Disconnected Rx Tx Obr 5 RS485 line indication LEDs and line ter...

Страница 16: ...tors and their respective LED indicators Connector type M12 D coding socket Connector Pin Signal Meaning X3 X4 1 TX Positive line conductor for data transmis sion 2 RX Positive line conductor for data...

Страница 17: ...vice rear cover part above Ethernet line connectors Following table describes meaning of individual LEDs LED Colour ACT X3 Green ACT X4 Green LED Meaning ACT X3 Lights Unit connection to Ethernet netw...

Страница 18: ...ony X2 Obr 8 Location of connector X2 with UIC interface Connector type WAGO 769 668 Connector Pin Signal Meaning X2 1 UIC1 Announcement audio signal 2 UIC2 Announcement audio signal 3 UIC3 Phone line...

Страница 19: ...ine is indicated by three LEDs on front panel Following table describes meaning of individual LEDs LED Colour Meaning AOC Yellow Priority announcement is going on TOC Yellow Phone call is going on POC...

Страница 20: ...en LEDs located above buttons acts as indicator of adjusted sound volume Line IN Obr 10 Location of an external audio input Connector type 3 5 mm jack socket Connector Pin Signal Meaning X5 1 L Audio...

Страница 21: ...ximum output power When needed whichever loudspeaker from combination can be substituted by resistor with the same impedance resistance and wattage Keep the loudspeaker polarity to avoid playing in th...

Страница 22: ...RRAM MCT E2 rram mcte2_g_en_100 22 31 A A Obr 13 Example of wiring four 4 speakers with min 8 W A A Obr 14 Example of wiring max 8 speakers 8 min 4 W...

Страница 23: ...RRAM MCT E2 23 31 rram mcte2_g_en_100 A A Obr 15 Example of wiring max 16 speakers 4 min 2 W...

Страница 24: ...ifier overload Blinks regularly Lights Improper unit configuration Blinks irregularly Lights Application start failed Application program is loaded device works faultless If too low impedance is attac...

Страница 25: ...d hold the RESTORE button while unit start up The PON LED first lights ON and after about 5 sec starts to blink Release the button after beginning of PON LED blinking After restoring of factory settin...

Страница 26: ...ng and installation rules The audio exchange unit is intended to be mounted into panel Four holes with 7 mm diameter are used for installation Unit can be mounted only in positions shown below Obr 18...

Страница 27: ...RRAM MCT E2 27 31 rram mcte2_g_en_100 9 1 Mounting holes 120 mm 118 mm 296 mm 310 mm 1 mm 7 mm 4 x D 7 m m Obr 19 Mounting holes...

Страница 28: ...ing terminal Minimum cross section of supplying conductors must be at least 0 5 mm2 Communication line wires must be shielded Shielding must be connected either to metal connector caps or to PE termin...

Страница 29: ...see chapter 10 1 10 1 Completion Part Quantity Train audio exchange unit 1 Power supply connector WAGO 769 110 counterpart 1 UIC interface connector WAGO 769 108 counterpart 1 Operation manual 1 Rout...

Страница 30: ...enance Depending on equipment usage the dust is to be removed occasionally from equipment The equipment can be cleaned by dry soft brush or vacuum cleaner only when turned off and disassembled The mai...

Страница 31: ...sal The disposal of electronic equipment is subject to the regulations on handling electrical waste The equipment must not be disposed of in common public waste It must be delivered to places specifie...

Отзывы: