Amit RB-RTE Series Скачать руководство пользователя страница 1

 

rb-rtexxx_g_en_100 

RB-RTExxx 

Ethernet router 

Operation manual 

Version 1.00 

 

Содержание RB-RTE Series

Страница 1: ...rb rtexxx_g_en_100 RB RTExxx Ethernet router Operation manual Version 1 00...

Страница 2: ...s must be copied without any changes 2 All redistributed copies must retain the AMiT spol s r o copyright notice and any other notices contained in the documentation 3 This document must not be distri...

Страница 3: ...y 17 6 1 Computer start up and shut down 18 6 1 1 SB input is used 18 6 1 2 SB input is not used 19 7 Digital inputs outputs 20 8 Communication lines and peripherals 21 8 1 Ethernet 22 8 1 1 10 100 Mb...

Страница 4: ...RB RTEXXX rb rtexxx_g_en_100 4 35 14 2 Package contents 33 14 3 Connectors 33 15 Maintenance 34 16 Waste disposal 35...

Страница 5: ...mentation 1 Application Note AP0037 Principles of using Ethernet network file ap0037_en_xx pdf 2 http www msc technologies eu manufacturer of the MSC Q7 BT CPU core Definition of used terms Train Comm...

Страница 6: ...om E3815 1 46 GHz 2 GB DDR3L RAM 4 GB eMMC FLASH RTC RAM and BIOS CMOS backup by battery optional 1 Gbps M12 X coded ETB and ECN Ethernet ports 2 ETB ports with bypass function 2 ECN ports 2 USB 2 0 h...

Страница 7: ...interfaces 2 Galvanic isolation Yes 1000 V AC 1 minute 2 Data transmission rate 10 Mbps 100 Mbps 1 Gbps Recommended cabling STP CAT6 Maximum segment length 100 m Operation indication 2 LED LNK and ACT...

Страница 8: ...ction cable Cu 2 2 5 mm2 30 cm 90 A 200 s Connection cable Cu 2 0 75 mm2 2 5 m Galvanic isolation Yes 1000 V AC 1 minute 2 Connection point WAGO 769 106 021 000 Wire cross section 0 75 mm2 to 1 5 mm2...

Страница 9: ...Communications signalling and processing systems Software for railway control and protection systems The device is not classified according to EN 50129 2003 Railway applications Communication signall...

Страница 10: ...iants RB RTExxx router can be supplied in following variants Name Digital I O Additional SATA SSD modules Weight netto Weight brutto RB RTE040 00A 0 No 1 88 kg 2 25 kg 2 2 Dimensions 55 181 260 30 240...

Страница 11: ...is router This drawing symbol is particular for RB RTE040 00A RB RTE040 00A PE Vcc GND X1 PWR 6 5 4 M12 X3 X4 X5 X2 M12 M12 M12 ECN ECN ETB ETB 3 2 1 NC NC SB Fig 2 Recommended drawing symbol 2 4 Bloc...

Страница 12: ...see Fig 4 S N TYPE RB RTE040 00A AB12345 HW REV MAC X2 MAC X3 MAC X4 MAC X5 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 POWER 16 8 to 50 4 V DC 0 6A WEIGHT TEST HiPot DATE...

Страница 13: ...s connector X4 MAC X5 xx xx xx xx xx xx MAC address connector X5 POWER 16 8 to 50 4 V DC 0 6 A Power supply voltage Consumption WEIGHT 1 88 kg Weight TEST OK xx Routine testing result HiPot HiPot OK H...

Страница 14: ...ndards Emission standard for industrial environments Complies EN 61000 4 2 2009 Electromagnetic compatibility EMC Part 4 2 EMC Testing and measurement techniques Indirect electrostatic discharge immun...

Страница 15: ...g stock Complies EN 50121 3 2 2016 Railway applications Electromagnetic compatibility EMC Part 3 2 Rolling stock equipment Complies EN 61373 2010 Railway applications Rolling stock equipment Shock and...

Страница 16: ...core contains processor Intel Atom E3815 2 GB DDR3L 4 GB eMMC For more details see the MSC Q7 module datasheet on manufacturer s website see Related documentation Master CPU module is equipped with eM...

Страница 17: ...al SB is used for turning router on and off terminal PE is used for connection to chassis Power supply terminals Vcc GND and SB is galvanically separated from internal electronics Galvanic isolation m...

Страница 18: ...inal thereby is initiated a correct process of systemic termination of application and operating system run Only after completion of operating system run and unit s shut down the supply voltage can be...

Страница 19: ...can be realized either by coincident connecting of power supply voltage to Vcc and SB terminals or by connecting the voltage first to Vcc terminal and then to SB or vice versa Nevertheless when starti...

Страница 20: ...n whether or not is the router equipped with digital inputs outputs can be found in the chapter 2 1 PWR X1 6 PE 5 Vcc 4 GND 3 SB 2 DIO1 1 DIO2 Fig 9 Power supply and digital inputs outputs connector C...

Страница 21: ...herals Router contains following communication interfaces and peripherals ETB Ethernet ECN Ethernet USB RS232 USB ETB ETHERNET ECN ETHERNET HDMI SYS LEDS POWER Fig 10 Location of peripherals on the fr...

Страница 22: ...internal network interface ports The application then handles the data transfers between the network interfaces Interfaces can be operated with 10 100 1000 Mbps speed Interfaces on X4 and X5 connector...

Страница 23: ...of wire X2 X3 X4 X5 1 Tx Orange white 2 Tx Orange 3 Rx Green white 4 Rx Green 8 1 2 1000 Mbps connection Connection utilizes all 8 pins of M12 connector for 4 pairs of cables Eight wire STP CAT6 or h...

Страница 24: ...thernet is inactive ON Ethernet connected ACT Blink Running communication OFF No communication 8 2 mSATA Router is equipped with one mSATA slot for additional memory module The type of the installed m...

Страница 25: ...ce company for router setup and configuration 9 1 USB Router has two USB host interfaces with type A connectors located on the front panel These two interfaces are compatible with USB 1 0 and USB 2 0...

Страница 26: ...line is not galvanically separated i e it is galvanically connected with router chassis Line is used as service interface Fig 17 RS232 connector Connector type D sub DE 9 plug PIN Signal Signal type o...

Страница 27: ...state indication is provided by LED SYS located on front panel Fig 18 System indication LED Status Meaning SYS OFF Power is OFF or system is not functional ON System is running HDD OFF No activity on...

Страница 28: ...a paper box Package dimensions are listed in chapter Technical parameters Sticker on the box contains following information Item Description TYPE RB RTE040 00A NETTO 1 88 kg BRUTTO 2 25 kg QTY 1 pc S...

Страница 29: ...not exceed 10 kg All load must be evenly spread over the entire upper side of the box Unpacked product must be stored only under the conditions specified in chapter Technical parameters Product may n...

Страница 30: ...ns another measures Free space of at least 100 mm must be left on the side of the connectors for cable connection and fastening It is very important to ensure that ambient temperature does not exceed...

Страница 31: ...wires must be protected against mechanical stress by binding to solid installation parts Length of cable or individual wire between last binding point and the control unit connector should not exceed...

Страница 32: ...ures Router is intended for mounting on the baseplate by means of four M5 bolts with low profile bolt heads Four holes located in corners with diameter of 6 mm are used for mounting 30 240 4x D 6 Fig...

Страница 33: ...ckage contents Part Quantity Router 1 Power supply connector WAGO 769 106 counterpart 1 Routine testing protocol 1 Insulation testing protocol 1 Certificate of product quality and completeness 1 14 3...

Страница 34: ...aning intervals have to be planned by the vehicle designer According to the dust and dirt contamination level there are cleaning ways as follows Dust settles on product and its cooler so thermal trans...

Страница 35: ...d together with common public waste It must be delivered to places specified for that purpose and recycled The equipment contains a lithium battery The battery is a dangerous waste Therefore it must b...

Отзывы: