Amit PPMB1 Series Скачать руководство пользователя страница 1

 

ppmb1xx_g_en_105 

PPMB1xx 

 

Series of recording units 

for rolling stock 

Operation manual 

Version 1.05 

 

Содержание PPMB1 Series

Страница 1: ...ppmb1xx_g_en_105 PPMB1xx Series of recording units for rolling stock Operation manual Version 1 05...

Страница 2: ...s must be copied without any changes 2 All redistributed copies must retain the AMiT spol s r o copyright notice and any other notices contained in the documentation 3 This document must not be distri...

Страница 3: ...eripherals 23 7 1 Video output 23 7 2 RS232 24 7 3 Ethernet 25 7 3 1 Wiring connector M12 4 pin 10 100 Mbps 26 7 3 2 Wiring connector M12 8 pin 10 100 Mbps 27 7 3 3 Wiring connector M12 8 pin 1000 Mbp...

Страница 4: ...5 4 47 10 Ordering information and completion 42 10 1 Ordering Information 42 10 1 1 Completion 42 10 2 Spare parts 43 11 Packaging 44 12 Storage 45 13 Maintenance 46 13 1 Backup battery replacement 4...

Страница 5: ...apter 9 4 term HDD or SSD replaced with Disk Chapter 9 4 moved certain Caution paragraphs Chapter 10 2 merged with chapter 10 3 into new chapter 10 2 Chapter 2 added Surface finish Added chapters 3 11...

Страница 6: ...HDD SSD depending on variant 2 USB host 1 video output micro HDMI 1 RS232 only Rx and Tx Ethernet 10 100 1000 Mbps RJ45 M12 4 pin M12 8 pin 2 digital input output Mounting on base plate When using 4pi...

Страница 7: ...Quantity 1 Operation indication LED Galvanic isolation Yes Galvanic isolation strength 500 V AC 1 minute Connection point RJ45 M12 4 pin M12 8 pin Recommended cabling STP CAT6 Maximum segment length 1...

Страница 8: ...ion indication No Galvanic isolation No Data transmission rate 12 Mbps 480 Mbps Recommended cabling Shielded USB cable Maximum cable length 3 m Connection point USB connector type A Nominal power supp...

Страница 9: ...C to 70 C Operating temperature range of HDD SSD Differs for single variants of PPMB1xx for precise information see chapter 8 2 Recording disks Storage temperature range 40 C to 70 C If the HDD SSD op...

Страница 10: ...not classified according to EN 50129 2003 Railway applications Communication signalling and processing systems Safety related electronic systems for signalling 2 1 Possible variants PPMB1xx series re...

Страница 11: ...PPMB1XX 11 47 ppmb1xx_g_en_105 2 2 Dimensions 142 145 4 175 4 230 190 68 5 D20 15 0 Fig 1 PPMB1xx dimensions...

Страница 12: ...Following drawing symbol is recommended for recording units from PPMB1xx series PPMB1xx X1 X2 X3 PE GND Vcc SB DIO1 DIO2 4 5 6 3 2 1 ETH USB2 USB1 RJ45 M12 USB USB X5 Micro HDMI Micro HDMI X4 RS232 R...

Страница 13: ...ure dependence Recording units from the PPMB1xx series have a temperature sensor which is measuring internal temperature of the device If the measured temperature exceeds 100 degrees Celsius the devic...

Страница 14: ...x Serial number MAC xx xx xx xx xx xx MAC address POWER 24 V DC 0 5 A WEIGHT x xx kg Weight of the unit TEST OK xx Routine testing result HiPot HiPot OK HiPot test result DATE dd mm yyyy Assembly date...

Страница 15: ...bility EMC Part 4 3 Testing and measurement techniques Radiated radio frequency electromagnetic field immunity test 800 MHz to 1000 MHz 20 V m EN 61000 4 3 2006 Electromagnetic compatibility EMC Part...

Страница 16: ...y applications Rolling stock equipment Shock and vibration tests Complies EN 60068 2 1 2007 Environmental testing Part 2 1 Tests Test A Cold Complies EN 60068 2 2 2007 Environmental testing Part 2 2 T...

Страница 17: ...supply negative terminal 5 Vcc Power supply positive terminal 6 PE Device chassis PWR EJECT USB X2 ETH X3 1 DIO2 2 DIO1 3 SB 4 GND 5 Vcc 6 PE PWR X1 HDD SYS ACT LNK RS232 X4 Fig 6 Power supply connec...

Страница 18: ...necting the voltage first to Vcc terminal and then to SB or vice versa Nevertheless when starting up an incorrect progress is not possible To prevent the data damage the unit must be shut down only by...

Страница 19: ...x_g_en_105 Vcc SB HW ton toff1 t APP Fig 7 Correct start up and shut down Incorrect shut down process is when the application doesn t turn off during toff2 Vcc SB HW ton toff2 t APP Fig 8 Incorrect st...

Страница 20: ...nnecting the voltage first to Vcc terminal and then to SB or vice versa Nevertheless when starting up an incorrect progress is not possible Signal SB can be connected directly with device Vcc terminal...

Страница 21: ...imultaneously PWR X1 6 PE 5 Vcc 4 GND 3 SB 2 DIO1 1 DIO2 Fig 9 Power supply and digital inputs outputs connector Connector type WAGO 769 666 PIN Signal Description 1 DIO2 Digital input output n 2 2 DI...

Страница 22: ...oltage from DIOx terminal Then it can be used as a digital input Outputs are equipped with thermal protection against short circuit Typical shutdown times when outputs are overloaded at 25 C ambient t...

Страница 23: ...xx series recording unit contains one Micro HDMI video output Video output connector is located on the side of the unit Supported resolutions are given by video driver built in recording unit BIOS and...

Страница 24: ...with recording unit chassis Line is used as service interface 2 RxD 5 GND 3 TxD 1 2 3 4 5 6 7 8 9 Fig 12 RS232 connector X4 Connector type D sub DE 9 plug PIN Signal Description 1 2 RxD Data input 3...

Страница 25: ...te RJ45 10 100 1000 Mbps M12 4 pin D coding 10 100 Mbps M12 8 pin X coding 10 100 1000 Mbps Ethernet EJECT USB X2 ETH X3 1 DIO2 2 DIO1 3 SB 4 GND 5 Vcc 6 PE PWR X1 HDD SYS ACT LNK RS232 X4 Fig 14 Loca...

Страница 26: ...ording unit front panel The LNK LED indicates connection of 100 or 1000 Mbps cable while connection of 10 Mbps cable is not indicated The ACT LED indicates the running communication on network 7 3 1 W...

Страница 27: ...wire STP CAT6 or higher cable can be used Tx 2 3 Rx 4 Rx NC Tx 1 NC NC NC C Fig 18 Connector M12 8 pin X coding four wire connection C coding NC not connected Connector PIN Signal Standard wire colour...

Страница 28: ...t wire STP CAT6 or higher cable must be used Da 2 3 Db 4 Db 5 Dd Da 1 Dc 8 6 Dd Dc 7 C Fig 19 Connector M12 8 pin X coding eight wire connection C coding Connector PIN Signal Standard wire colour X3 1...

Страница 29: ...pins oRJ 45 connector for pair Tx Tx and pair Rx Rx Four or eight wire STP CAT6 or higher cable can be used Pin 1 Fig 20 Connector RJ 45 four wire connection Connector PIN Signal Standard wire colour...

Страница 30: ...ge 7 Dd Brown white 8 Dd Brown 7 4 USB This is a standard PC interface PPMB1xx series recording units contain one connection point X2 with two USB type A connectors host and one USB port with Type B c...

Страница 31: ...DD SYS ACT LNK RS232 X4 Fig 24 User button location Number Description 1 User button 7 6 Indication LED Recording unit is fitted by two or four LED indicators on its panel They are used for indication...

Страница 32: ...n of LEDs LED label colour State indicated Indication LNK green orange Connected to 100 Mbps Ethernet network Connected to 1000 Mbps Ethernet network Light ACT green Data transfer via Ethernet Flashin...

Страница 33: ...PPMB1XX 33 47 ppmb1xx_g_en_105 LED EJECT USB X2 ETH X3 1 DIO2 2 DIO1 3 SB 4 GND 5 Vcc 6 PE PWR X1 HDD SYS ACT LNK RS232 X4 Fig 26 Location of LEDs...

Страница 34: ...g in module These disks can not be used as operating system mass storage The Master CPU is able to switch on off the power supply voltage of individual disks in case the equipment internal temperature...

Страница 35: ...with higher reliability demands Disadvantage is higher initial cost Parameters SSD SSD industrial Recording capacity High Lower Cost Higher High Lifetime 5 years 5 years Operating temperature range 0...

Страница 36: ...ving parts HDD it must be mounted on SB 20X15DD anti vibration rubber pads After the plug in module with disks is installed it must be secured with locking bolts see chapter 9 4 Handling the disks Fai...

Страница 37: ...ged by additional means fans another measures A free space of at least 18 cm must be left on the connector side of the recording unit for ejection of frame with hard disks and connection and fastening...

Страница 38: ...chanical stress by binding to solid installation parts Length of cable or individual wire between last binding point and the control unit connector should not exceed 15 cm Ethernet line connection mus...

Страница 39: ...ed for mounting on the baseplate by means of four M5 screws with low profile heads Four holes located in corners with diameter of 5 mm are used for mounting 209 121 5 Fig 29 Mounting holes spacing MAX...

Страница 40: ...can be performed only when the equipment is powered off never when operating Data loss or damage can occur 1 2 Fig 31 Inserting and pulling out the frame with hard disks Number Description 1 Locking b...

Страница 41: ...ten with final torque of 0 5 Nm 1 3 2 Fig 32 Mounting of disks to the plug in module two disks 1 2 Fig 33 Mounting of disks to the plug in module one disk Number Description 1 Screw M3 04 apply thread...

Страница 42: ...TB user button 1 RS232 2 USB type A Micro HDMI Complete see chapter PPMB1011 1D1D Ethernet M12 4 pin 2 SSD 1 TB user button 1 RS232 2 USB type A Micro HDMI Complete see chapter PPMB1011 xx Ethernet M1...

Страница 43: ...an be ordered ZM_PPM2000 A Plug in module without HDD screw set 4 M3 06 with cylinder head SP_MB247720 Backup battery module Anti vibration pad SB 20X15DD 4 anti vibration pad with screw and flat spri...

Страница 44: ...inst impacts with special pads Sticker on the box contains following information Item Description TYPE PPMB1xxx xx NETTO x xx kg BRUTTO x xx kg QTY 1 pc S N Serial number AMiT logo QR code CE symbol T...

Страница 45: ...0 kg Load must be evenly spread over the entire upper side of the box Unpacked product must be stored only under the conditions specified in chapter 2 Technical parameters Product may not come into co...

Страница 46: ...ast every five years If special panel computer usage conditions are comply with the service interval can be prolonged according to chart on Fig 36 Backup battery change interval Special usage conditio...

Страница 47: ...sed of in common public waste It must be delivered to places specified for that purpose and recycled The equipment contains a lithium battery The battery is a hazardous waste Therefore it must be deli...

Отзывы: