SAFETY REQUIREMENTS:

Not applying to the following instructions and 

any mechanical interference with the product 

excempts the manufacurer’s liability for 

damages resulting from the use of the device 

and cancels warranty rights.

•  when refueling, wear PVC safety gloves 

to avoid skin irritation resulting from 

exposure to hydrocarbons.

•  do NOT smoke using or servicing the fuel 

distributor.

•  the device can only be opened by qualified 

electricians in spite of the high voltage 

inside.

•  do NOT cross the device’s max. parameters.

•  do NOT leave working device without 

supervision.

•  before turning the device on, make sure 

that all the wires and the whole device are 

intact.

•  do NOT turn the device on, being barefool, 

having wet hands or standing in water.

•  do NOT start the device when it’s not 

complete, do NOT remove any of it’s parts.

•  keep the electric wire and the switch box 

far  from  splashing  water  or  other  fluids. 

Protect it against weather conditions.

INPROPER USE:

•  pumping sea wateer, dirty water, water 

containing corrosive substances or 

solid particles like sand, liquids whose 

temperature is over 90

o

C, food liquids, 

flammable, explosive liquids.

•  device use by children, without adult’s 

supervision.

•  using the device without any liquid to 

pump.

USAGE:

•  the pump is powered with 12V (P/N: 02066, 

02068), 24V (P/N: 02069).

•  before starting to work with the pump, 

make sure that there is already some oil 

in the tank.

•  oil should not be pumped into completely 

empty tank.

•  pay attention to the pump’s capatity. It 

can not be exceeded when the device is 

working.

•  the device should be used only for 

pumping  oil,  the  flow  is  12  l/min.  (P/N: 

02066), 30 l/min. (P/N: 02068, 02069).

•  the  max.  diameter  of  the  outflow  is  16-

18 mm (P/N: 02066), 19 mm (P/N: 02068, 

02069).

•  THE BOTTOM OF THE PUMP HAS TO BE 

IMMERSED IN THE LIQUID.

Do not start the device if you are not sure that 

both suction and outflow conduit are properly 

installed.

FIRST AID:

In case if oil has bee swallowed - do not induce 

vomit. A large amount of water or milk should 

be given to drink to the person.

In case when somebody has been 

electrocuted - cut off the source of power or, 

protecting yourself with a dry insulator, take 

the electrocuted person away from the source 

of electricity. Do not touch the person that has 

been given an electric shock with bare hands 

as long as the person is in a safe distance from 

the source of electricity. Emergency services 

should also be immadiately called.

TRANSPORT:

The device does not require assembly as 

it is delivered complete. In the case when 

the pachage is visibly damaged, check if the 

device itself is not damaged likewise. Before 

starting to work with the device make sure 

that the data on the nameplate allows the 

device to be used at the place of destination.

Transport the device only when the power 

cord  and  both  suction  and  outflow  conduits 

have been disconnected. Do NOT move the 

device by pulling the power cord.

TROUBLESHOOTING:

THE PUMP WILL NOT START:

1.  No power supply - Check the power 

connection

2.  The engine does not work - Ontant service

EN

PL

ES

CZ

SK

Содержание 02066

Страница 1: ...in the tank oil should not be pumped into completely empty tank pay attention to the pump s capatity It can not be exceeded when the device is working the device should be used only for pumping oil t...

Страница 2: ...INSTRUKCJA OBS UGI Pompa do oleju nap dowego WYMOGI BEZPIECZE STWA Nieprzestrzeganie poni szych ostrze e i ingerowanie w silnik dystrybutora zwalnia producenta z odpowiedzialno ci za szkody wynik e z...

Страница 3: ...SPORT Dystrybutor dostarczany jest w stanie kompletnym i nie wymaga adnego monta u Silnik mo e by naprawiany wy cznie przez autoryzowany personel 1 Rozpakowywanie W przypadku stwier dzenia uszkodzenia...

Страница 4: ...e salpicaduras de agua u otros l quidos y protejalos de las precipitaciones atmosf ticas USO INADECUADO bombeo de agua de mar agua sucia agua que contengan s lidos como arena y substancias corrosivas...

Страница 5: ...anguera de aspiraci n no esta sumergida en el combustible Sumer ja profundamente a manguera en el combustible 4 Capacidad de bombeo demasiado alta Ponga en un n vel m s bajo el recipiente donde se est...

Страница 6: ...padla mus b t pono en v kapalin POZOR Je zak z no nech vat p stroj v provozu bez dohledu proto e by to mohlo zp sobit nik paliva nebo p epln n n dr e Nespou t jte erpadlo bez instalac hadic sac a v tl...

Страница 7: ...eto ho m e otv ra iba kvalifikovan person l a autorizovan elektrik ri neprekra ujte maxim lne parametre pr stroja ako s ur en nenech vajte pr stroj po as prev dzky bez dozoru pred zapnut m erpadla sa...

Страница 8: ...je udr iava erpadlo ist Zariadenie nevy aduje iadnu vn torn dr bu a preto by sa nemalo nikdy rozobera ERPADLO SA NECHCE ZAPN 1 iadna sila skontrolujte pripojenie nap jania 2 motor nebe kontaktujte ser...

Отзывы: