amiad DVF Скачать руководство пользователя страница 34

 

 

910101-001048 

                                         12/2019 

Page 34 of 42 

 

Amiad Limited Warranty 

 

1.

 

This certificate applies to Amiad Water Systems Ltd. ("

Amiad

") products purchased by you (the "

Buyer

") from Amiad unless specifically agreed 

otherwise in writing by Amiad. This Warranty extends only to the original purchaser, and  is  not transferable to anyone who subsequently 

purchases, leases, or otherwise obtains the product from the original purchaser.  

2.

 

Amiad hereby warrants that the products are and will be free from defects in material and workmanship under normal use and service. Amiad 

warrants that it will correct manufacturing defects in the products, in accordance with the conditions set out in this Warranty. 

3.

 

This Warranty is enforceable for a period of 12 months after the date upon which the products were delivered (the “

Warranty Period

”).  

4.

 

In the event that  during the  Warranty Period  the  Buyer discovers a  defect in material and/or workmanship in any  product  or part (the 

Defective Product

”), it shall submit a written complaint to Amiad using Amiad's standard Buyer Complaint Form. For the receipt of the Buyer 

Complaint Form, the submission of the complaint or any questions please contact your service representative.  

5.

 

Upon written demand by Amiad the Buyer shall return the Defective Product - or a sample thereof - to Amiad, at Amiad's cost. If the Buyer 

ships any such Defective Product, Amiad suggests the Buyer package it securely and insure it for value, as Amiad assumes no liability for any 

loss or damage occurring during shipment. Provided however that in the event Amiad determines that this Warranty does not apply to such 

product, Buyer  shall promptly reimburse Amiad for such cost (including  freight  and customs). Any returned  product or part must be 

accompanied by the Warranty certificate and the purchase invoice. It is clarified that the Buyer may not return the Defective Product unless 

such return was coordinated and approved by Amiad in advance.   

6.

 

Amiad's obligation under this Warranty shall be limited to, at Amiad's option, the repair or exchange, free of charge, of the product or any part 

which may prove defective under normal use and service during the Warranty Period. The provision of a repair or replacement of a product 

during the Warranty Period will result in an extension of the Warranty Period by an additional period of 12 months, provided that the total 

accumulated Warranty Period shall in any event be no more than 18 months from the date upon which the products were delivered.  

7.

 

This Warranty is valid on the condition that the products are installed according to Amiad's instructions as expressed in Amiad's instruction 

manuals and according to the technical limitations as stipulated in Amiad's literature or as stated by a representative of Amiad.  

8.

 

This Warranty will not apply to damaged or defective products resulting from or related to:  

(i)

 

Fire, flood, power surges or failures or any other catastrophe and/or unforeseen occurrence, such as but not limited to those for which 

the Buyer is customarily insured for, or any force majeure events;  

(ii)

 

Fault, abuse or negligence of the Buyer;  

(iii)

 

Intake water not meeting the agreed standards, as set forth in a written document, approved by Amiad, or improper storage;  

(iv)

 

Improper or unauthorized use of the product or related parts by  the Buyer, including  Buyer’s  failure to operate the product in 

conformity with the recommendations and  instructions of  Amiad, as set forth in Amiad's manuals and other written materials,  the 

operation of the product other than by a trained and qualified operator, or improper installation of the product by a third party not 

authorized by Amiad;  

(v)

 

Performance by the Buyer of maintenance or operation other than in conformity with the recommendations and instructions of Amiad, 

or other than in accordance with procedures defined in the literature supplied for products  (including the  timely replacement of 

requisite parts), and for services provided other than by a trained and qualified advanced operator; or 

(vi)

 

Any alteration, modification, foreign attachment to  or repair of the products,  other than by Amiad  or its authorized  technical 

representatives.  

9.

 

In no event shall Amiad be liable to the Buyer or any third party for any damages to property, or for any intangible or economic loss, including 

loss of profits, loss of customers or damage to reputation, for any damages, including indirect, special, consequential damages, or punitive 

damage arising out of or in connection with this Warranty, or arising out of or in connection with the product's performance or failure to 

perform, even if it has been advised of the possibility of such damages.  

10.

 

Amiad will be excused for failure  to perform  or for delay in performance hereunder if such failure or delay is due to  causes beyond its 

reasonable control or force majeure preventing or hindering performance. 

11.

 

This Warranty set forth herein is the only contractual warranty given by Amiad and is provided in lieu of any other warranties created by any 

documentation, packaging or otherwise.  

12.

 

Amiad makes no warranty whatsoever in respect to accessories or parts not supplied by Amiad. In the event that Amiad is required to correct a 

Defective Product or product not covered by this Warranty, it will do so solely in consideration for additional fees. 

13.

 

The parties will actively endeavor to amicably settle any dispute arising between them. In the event that the parties are unable to reach an 

equitable settlement of such dispute, any claim or lawsuit related to the Warranty, its validity execution, its performance be brought before 

only the courts of Tel-Aviv, Israel. Israeli law will govern the Warranty, to the exclusion of any conflict of law rules 

Содержание DVF

Страница 1: ...iltration System Serial Numbers _____________________ Order number _____________________ Catalog number _____________________ Filtration degree _____________________ Year _____________________ Installation Operation and Maintenance Instructions December 2019 Original Instructions 910101 001048 ...

Страница 2: ...its content The confidential nature of and or privilege in the file enclosed is not waived or lost as a result of a mistake or error in this file If you received this file in error please notify Amiad immediately at info amiad com This document does not replace any certified drawing procedure or information provided by Amiad in reference to a specific customer site or project Amiad assumes that al...

Страница 3: ...First Operation 17 3 Periodic Iinspection 17 4 Monthly Maintenance 17 5 Yearly Maintenance 18 6 Replacing the filter media 18 Parts Maintenance 19 1 Filter Vessel 19 2 Filter Media PEP ACTIVE Activated Filter Media 19 DVF 300 Filter GA Drawing 21 DVF 300 Filter Parts Drawings 22 DVF 300 Filter Parts List 23 DVF 600 Filter GA Drawing 24 DVF 600 Filter Parts Drawings 25 DVF 600 Filter Parts List 23 ...

Страница 4: ...scharging wastewater to drain it is the responsibility of the user to determine the legal discharge route for contaminated water from the filter Electrical connections should be done in accordance with national standards and carried out by competent persons only Amiad filtration products always operate as components in a larger system It is essential for the system designers installers and operato...

Страница 5: ...ce with the relevant standards and regulations For shipping lifting and positioning the filter use only approved lifting equipment authorized employees and contractors Pneumatics Ensure that the compressed air supplied to the filter never exceeds the maximum designated pressure for the filter An air pressure reduction valve should be installed on the compressed air supply line upstream of the filt...

Страница 6: ... use the filter for purposes other than its original design and operational envelope 4 Maintenance Servicing the filter should be performed by an authorized manufacturer s technician only Before any maintenance or non regular operation carefully read the following Disconnect the filter from the power supply and lock the main power switch Disconnect any compressed air supply release the residual pr...

Страница 7: ...h water pressure or steam should be performed in accordance with cleaning system instructions local standards and regulations and without endangering the operator or the vicinity Before returning to regular operation Re assemble any protective covers or protection mechanisms removed during service or maintenance operations Ensure that all the tools ladders lifting devices etc used during the maint...

Страница 8: ...N10 Flanged Process Water Outlet Connection 1 DN 25 ISOPN10 Flanged 1 DN 40 ISOPN10 Flanged 2 DN 50 ISOPN10 Flanged 3 DN 80 ISOPN10 Flanged Backwash Inlet Connection 1 DN 25 ISOPN10 Flanged 1 DN 40 ISOPN10 Flanged 2 DN 50 ISOPN10 Flanged 3 DN 80 ISOPN10 Flanged Backwash Outlet Connection 1 DN 25 ISOPN10 Flanged 1 DN 40 ISOPN10 Flanged 2 DN 50 ISOPN10 Flanged 3 DN 80 ISOPN10 Flanged Minimum Operati...

Страница 9: ...s supplied with multi level graded glass The backwash period is adjustable depending on the nature of the contamination being removed Filter Configuration The DVFis a patented filter system for water which can remove particulate down to 1 micron nominal in size Each unit has a total of four valve connections namely Process Inlet Valve V1 This is the filter s inlet connection for the dirty process ...

Страница 10: ... continues on line filtration until backwash is initiated This is usually done via a pressure differential switch supplied as part of the control package a timer adjustable through the controller or manually by pressing the backwash button Once backwash is triggered by either of the above V1 and V2 close the filter will no longer be producing any process water until the backwash cycle is complete ...

Страница 11: ... the vessel air inlet If the airline is relatively long calculate the dynamic head loss and take it in to account An air valve MUST be installed to handle the blower air flow with the minimal hydraulic resistance ARI D070P model is recommended A vacuum breaker MUST be installed on the drain line Process Description Partial Draining This stage is designed to enable room on the upper part of the ves...

Страница 12: ...he filter and run the BW cycle DVF Scouring Design Table DVF Model Scouring Pressure Bar Scouring Velocity m hr Vessel Diameter m Vessel Area m Nominal Operation Flow m h DVF 300 0 5 0 6 70 0 3 0 07 5 DVF 600 0 5 0 6 70 0 6 0 28 20 DVF 900 0 5 0 6 70 0 9 0 64 45 DVF 1200 0 5 0 6 70 1 2 1 13 79 ...

Страница 13: ...nt temperatures of below 2 C without heat tracing If there is any risk of this you should consult with Amiad Water Systems Connect inlet outlet process pipe work backwash and drain to the unit as necessary and check all filter connections for tightness as fittings may become loose during transit Remember not to overtighten the connections If the control panel doesn t come pre mounted mount it adja...

Страница 14: ... to the differential pressure switch Electrical Connections Electric wiring must be performed by an authorized electrician only using standardized and approved components Install a lockable main power cut off switch close to the control panel If due to site constraints the control panel is installed without a clear line of vision to the filter an additional lockable power disconnect cut off switch...

Страница 15: ... use correct PPE during media installation See media data sheets which can be found on the bags and further in this document o First ensure that the valves on the backwash inlet V3 and process outlet V2 are closed o Now via the top flange fill half the vessel with clean fresh water This is to ensure no damage occurs to the backwash nozzles located within the vessel base o Load the base media in th...

Страница 16: ...e 1 Depth mm 181 212 251 212 Weight kg 16 75 200 300 of Bags 3 Bags 8 Bags 12 Bags Grade 2 Depth mm 219 200 287 305 Weight kg 19 75 225 425 of Bags 3 Bags 9 Bags 17 Bags Grade 3 Depth mm 232 218 161 210 Weight kg 20 75 125 290 of Bags 3 Bags 5 Bags 12 Bags Total Bed Weight kg 85 350 800 1465 Total Bed Height mm 951 978 996 1025 Media configurations can vary according to process ...

Страница 17: ...Flush the filter until the backwash outlet V4 water is clean Note Ensure minimal backwash flowrate according to the technical data table pp 8 3 Switch to Auto operation mode 4 Adjust all operational setpoints in the control system as per control philosophy Recommendations clean DP 0 3 bar Backwash trigger DP 0 8 bar 3 Periodic Inspection 1 Check for leaks from connections and fittings If leaks are...

Страница 18: ...lter media through the service hole on the side of the filter Thoroughly clean the inside of the filter with clean water Inspect the filter mushrooms and the double bottom Carefully close the service covers on the side Fill the filter media through the filling hole top lid and continue to follow the instructions in the section Media Filling Process 6 Replacing the filter media 1 Replace the filter...

Страница 19: ...spect condition of securing bolts replace as required 2 Filter Media PEP ACTIVE Activated Filter Media Weekly Maintenance Check and log differential pressure Monthly Maintenance Perform a manual backwash cycle and visually inspect drain for media carry Yearly Maintenance Removal of upper hatches for media inspection Perform a media sanitation disinfection if required solution of hypochlorite 5 Top...

Страница 20: ...910101 001048 12 2019 Page 20 of 42 DVF Filter P ID Drawing ...

Страница 21: ...910101 001048 12 2019 Page 21 of 42 DVF 300 Filter GA Drawing ...

Страница 22: ...910101 001048 12 2019 Page 22 of 42 DVF 300 Filter Parts Drawing ...

Страница 23: ...WITCH W BRACKET BACCARA 1 8 BSPM REAR 14BAR 0 5BAR IP66 12794121 1 Various 6 770103 000471 GASKET 1 ISO PN10 EPDM DN25 TH2MM FULL FACE 4 EPDM 7 730104 000573 2 WAY BALL VALVE 1 ISO10 2528 S ST ELECTRIC HQ 004 DN25 GENEBRE ACT SOL 4 Various 7 730104 000573 2 WAY BALL VALVE 1 ISO10 2528 S ST ELECTRIC HQ 004 DN25 GENEBRE ACT SOL 4 Various 7 1 730104 000572 2 WAY BALL VALVE 1 ISO10 2528 S ST W O ACTUA...

Страница 24: ...910101 001048 12 2019 Page 24 of 42 DVF 600 Filter GA Drawing ...

Страница 25: ...910101 001048 12 2019 Page 25 of 42 DVF 600 Filter Parts Drawing ...

Страница 26: ... 316 5 720101 000776 FLUSHING CONTROLLER TECNOLOGIC 5REL S240VAC AC 5 BESPOKE FOR DVF 1 Various 6 720104 000025 DP SWITCH W BRACKET BACCARA 1 8 BSPM REAR 14BAR 0 5BAR IP66 12794121 1 Various 7 730104 000574 2 WAY BALL VALVE 1 1 2 ISO10 2528 S ST ELECTRIC HQ 004 DN40 GENEBRE ACT SOL 4 VARIOUS 7 1 730104 000575 2 WAY BALL VALVE 1 1 2 ISO10 2528 S ST W O ACTUATOR DN40 GENEBRE 4 S ST 304 7 2 720701 00...

Страница 27: ...910101 001048 12 2019 Page 27 of 42 DVF 900 Filter GA Drawing ...

Страница 28: ...910101 001048 12 2019 Page 28 of 42 DVF 900 Filter Parts Drawing ...

Страница 29: ...T316 1 4 BSP BOTTOM 2 W GLYCERINE 2 S ST 316 6 720101 000776 FLUSHING CONTROLLER TECNOLOGIC 5REL S240VAC AC 5 BESPOKE FOR DVF 1 Various 7 720104 000025 DP SWITCH W BRACKET BACCARA 1 8 BSPM REAR 14BAR 0 5BAR IP66 12794121 1 Various 8 730104 000577 2 WAY BALL VALVE 2 ISO10 2528 S ST ELECTRIC HQ 004 DN50 GENEBRE ACT SOL 4 VARIOUS 8 1 730104 000576 2 WAY BALL VALVE 2 ISO10 2528 S ST W O ACTUATOR DN50 ...

Страница 30: ...910101 001048 12 2019 Page 30 of 42 DVF 1200 Filter GA Drawing ...

Страница 31: ...910101 001048 12 2019 Page 31 of 42 DVF 1200 Filter Parts Drawing ...

Страница 32: ...ST316 1 4 BSP BOTTOM 2 W GLYCERINE 2 S ST 316 6 720101 000776 FLUSHING CONTROLLER TECNOLOGIC 5REL S240VAC AC 5 BESPOKE FOR DVF 1 Various 7 720104 000025 DP SWITCH W BRACKET BACCARA 1 8 BSPM REAR 14BAR 0 5BAR IP66 12794121 1 Various 8 730104 000579 2 WAY BALL VALVE 3 ISO10 2528 S ST ELECTRIC HQ 008 DN80 GENEBRE ACT SOL 4 VARIOUS 8 1 730104 000578 2 WAY BALL VALVE 3 ISO10 2528 S ST W O ACTUATOR DN80...

Страница 33: ...leshooting Flowchart The majority of faults and problems are associated with the installation rather than the filter system itself Here is a flow chart of the most common faults in order that you may check them before calling our service technicians ...

Страница 34: ...ve of Amiad 8 This Warranty will not apply to damaged or defective products resulting from or related to i Fire flood power surges or failures or any other catastrophe and or unforeseen occurrence such as but not limited to those for which the Buyer is customarily insured for or any force majeure events ii Fault abuse or negligence of the Buyer iii Intake water not meeting the agreed standards as ...

Страница 35: ...910101 001048 12 2019 Page 35 of 42 Annex A Media Safety Data Sheet 7 pages ...

Страница 36: ...910101 001048 12 2019 Page 36 of 42 ...

Страница 37: ...910101 001048 12 2019 Page 37 of 42 ...

Страница 38: ...910101 001048 12 2019 Page 38 of 42 ...

Страница 39: ...910101 001048 12 2019 Page 39 of 42 ...

Страница 40: ...910101 001048 12 2019 Page 40 of 42 ...

Страница 41: ...910101 001048 12 2019 Page 41 of 42 ...

Страница 42: ...r the CE marking in conformity with the art 4 par 3 Pressure Equipment Directive 2014 68 EU Manufacturer Amiad Water Systems Ltd D N Galil Elyon 1 1233500 Israel Tel 972 4 690 9500 Fax 972 4 814 1159 Email info amiad com EC Representative for CE Matters Obelis S A Boulevard Général Wahis 53 B 1030 Brussels BELGIUM Email info obelis com ...

Отзывы: