29
VIII. TROUBLE SHOOTING
TROUBLE
CAUSE
REMEDY
Motor does
not run
1. Button does not work
2.Wiring connections are not in good
condition
3. Motor burned out
4. AC contactor burned out
5. Height limit switch is damaged
1.Replace button
2.Repair all wiring connections
3.Repair or replace motor
4.Replace AC contactor
5.Replace
Motor runs
but the lift is
not raised
1.Motor runs in reverse rotation
2. Release valve in damage
3. Gear pump in damage
4.Relief valve or check valve in damage
5.Low oil level
1.Reverse two power wire
2.Repair or replace
3.Repair or replace
4.Repair or replace
5.Fill tank
Lift does not
stay up
1. Release valve out of work
2 Relief valve or check valve leakage.
3.Cylinder or fittings leaks
Repair or replace
Lift
raises
too slow
1.Oil line is jammed
2.Motor running on low voltage
3. Oil mixed with Air
4.Pump leaks
5.Overload lifting
1.Clean the oil line
2.Check electrical system
3. Fill tank
4.Replace Pump
5.Check load
Lift cannot
lower
1. Safety device are in activated
2. Release valve damaged
3. Air Cylinder damaged
4. Oil system is jammed
1. Release the safeties
2. Replace or repair
3.Replace the cylinder
4. Clean the oil system
Содержание PRO-14
Страница 1: ...FOUR POST LIFT PRO 14...
Страница 2: ......
Страница 4: ......
Страница 11: ...7 D Install cross beams See Fig 11 Fig 12 Fig 11 Hole towards inside 1 3 2 3 Fig 12...
Страница 25: ...21 O Install spring and safety cover of cross beam See Fig 34 Fig 34 3 3 3 8 40 3 2 Fig 33...
Страница 27: ...23 IV EXPLODED VIEW Model PRO 14 Fig 36...
Страница 28: ...24 3 73 74 CROSS BEAM CYLINDERS Fig 37 Fig 38...
Страница 29: ...25 MANUAL POWER UNIT Fig 39 220V 50HZ 1 phase 380V 50HZ 3 phase...
Страница 39: ......
Страница 40: ...AMGO HYDRAULIC CORPORATION Tel 803 505 6410 Fax 803 505 6410 1931 Jo Rogers Blvd Manning South Carolina USA...