Features and Specifications
Mechanical Specifications
29
Mechanical Specifications
Front Panel Voltage and Current
Control
10-turn voltage and current potentiometers
Front Panel Voltage Control
Resolution
0.02% of maximum voltage
Front Panel Voltage and Current
Meters
3.5-digit numeric LED displays (for accuracy
specifications, see Table 1.2 and Table 1.3)
AC Input Connector Type
IEC 320 Connector, appropriate power cord
for destination country.
Front Panel Output
5-way binding posts:
maximum current limit 30 A
OVP Control
Screwdriver-set potentiometer on front panel
Input Fuses
20 A, 250 V, 5 x 20 mm slow fuses,
location: A5 PCB, F321, 325;
0.005 A, 250 V, 5 x 20 mm fast fuse,
location: A3 PCB, F1.
Main Output Connector
7.5 V to 40 V models: nickel-plated copper
bus bars;
60 V to 600 V models: 4-terminal wire clamp
connector for DC output and local sense.
Analog Programming, Monitoring,
and Sense Connector (2-piece)
12-terminal wire clamp connector
Chassis Ground
Chassis ground screw located on rear panel
for bonding connections
Cooling
Fan cooled. Air exhausts to rear. Over
temperature shutdown: automatic restart or
latch off (switch-selectable).
Mounting
Optional rack mount pan. (RM3-XHR)
Size (one unit)
87.0 mm H x 214.6 mm W x 472.2 mm D
(3.425in. H x 8.45in. W x 18.59in. D)
Weight (one unit)
Approximately 6.4 kg (14 lb.)
Содержание Sorensen XHR 100-10
Страница 2: ......
Страница 4: ...This page intentionally left blank ii ...
Страница 6: ...This page intentionally left blank iv ...
Страница 8: ...This page intentionally left blank vi ...
Страница 12: ...List of Figures x Operating Manual for XHR Series Power Supply ...
Страница 14: ...List of Tables xii Operating Manual for XHR Series Power Supply ...
Страница 47: ...Installation Load Connection 47 Figure 2 9 Multiple Loads with Remote Sensing ...