Local and Remote Sensing
TM-F1OP-C1XN-01
2-25
Using Remote Sensing
Use remote sensing during voltage mode operation to shift the power
supply’s regulation point from its default position at the rear panel output
terminals to the load or distribution terminals by using a separate pair of
wires to allow the control circuitry to monitor the load voltage. This
allows the power supply to compensate for voltage losses in the load lines
which will otherwise degrade the regulation of the supply. Line drop is
subtracted from the total voltage available at the output.
To connect remote sense lines:
1. Turn OFF the power supply.
2. Remove the local sense jumpers connecting J10 mating connector
terminal 5 (positive sense) to terminal 4 (positive output) and
terminal 1 (return sense) to terminal 2 (power supply return).
3. Connect the positive remote sense lead to J10 mating connector
terminal 5 (positive sense) and the negative lead to terminal 1 (return
sense). Ensure the mating connector is plugged securely into the rear
panel sense connector. Connect the other ends of the sense wires to
the corresponding sense points at the load.
4. To prevent ground loops, ground the sense line shield, at one point
only, to the power supply’s return output connection at the load, to the
power supply's return output at its negative output terminal, or to the
power supply’s chassis.
WARNING
There is a potential shock hazard at the sense points when using a power supply with
a rated output greater than 40 V. Ensure that connections at the load end are shielded
to prevent contact with hazardous voltages.
CAUTION
Ground the sense line shield in one place only. Locations include: the power
supply’s return output connection at the load, the power supply’s return output at its
negative output terminal, or at the power supply’s chassis.
CAUTION
Do not use remote sensing with multiple supplies connected in series.
TM-F1OP-C1XN-01.book Page 25 Thursday, October 25, 2007 9:04 PM
Содержание Sorensen XFR 1200 Watt Series
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 6: ...This page intentionally left blank ii...
Страница 8: ...This page intentionally left blank iv...
Страница 10: ...This page intentionally left blank vi...
Страница 16: ...xii TM F1OP C1XN 01 book Page xii Thursday October 25 2007 9 04 PM...
Страница 18: ...xiv TM F1OP C1XN 01 book Page xiv Thursday October 25 2007 9 04 PM...
Страница 30: ...1 12 TM F1OP C1XN 01 book Page 12 Thursday October 25 2007 9 04 PM...
Страница 57: ...Local and Remote Sensing TM F1OP C1XN 01 2 27 TM F1OP C1XN 01 book Page 27 Thursday October 25 2007 9 04 PM...
Страница 58: ...2 28 TM F1OP C1XN 01 book Page 28 Thursday October 25 2007 9 04 PM...
Страница 82: ...4 8 TM F1OP C1XN 01 book Page 8 Thursday October 25 2007 9 04 PM...
Страница 94: ...5 12 TM F1OP C1XN 01 book Page 12 Thursday October 25 2007 9 04 PM...