Asterion DC Multioutput Series
Programming Manual
10-78
M330517-01 Rev C
Command
Description
SCPI
OUTPut<n>:STATe <boolean>
Sets the output to zero or the programmed value;
enable or disable the output Valid arguments are
1/ON or 0/OFF. *RST state value is ON.
C
OUTPut<n>:STATe?
Returns the state of the output:
1 = ON 0 = OFF
C
OUTPut<n>:TRIPped?
Returns the integer value 1 (TRIPPED) or 0
(UNTRIPPED) state of the output.
N
OUTPut<n>:REMote:INHIBIT <0|1>
The Remote Inhibit will work in LATCH and LIVE
mode
. LATCH:
An open contact between remote
inhibit terminal and return latches the output in the
protection shutdown state; this state could be
cleared either through the front panel fault screen
or by sending the SCPI command
OUTP<n>:PROT:CLE.
LIVE:
The output state follows the state of the
Remote Inhibit input. An open contact between the
remote inhibit terminal and return will turns the
output off; a contact closer between remote inhibit
terminal and return turns the output on.
N
OUTPut<n>:REMote:INHIBIT?
Returns the state of the Inhibit:
1 = LATCH 0 = LIVE
N
SYSTEM SCPI Command Subsystem
This section first presents a tree summary of the SYSTem commands and then provides
a tabular description.
10.8.1
SYSTEM SCPI Command Summary
SYSTem
:
ERRor?
:
PROGDELAY
:REFrence <1|2|3>
:REFrence?
:ENABLE <1> <2> <3>
:ENABLE?
:DISABLE
:DELAY <NRf>,<NRf>,<NRf>
:DELAY?
:OUTP
:STAT <boolean>
:STAT?
:LOCAL <boolean>
:LOCAL?
:NET
:AUTOIP <boolean>
:AUTOIP?
:DESC <string>
:DESC?
Содержание Sorensen Asterion DC ASM
Страница 1: ...M330517 01 Rev C Asterion DC Multioutput Series Programming Manual...
Страница 6: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C v SAFETY SYMBOLS...
Страница 17: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C xvi This page intentionally left blank...
Страница 20: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C 1 3 This page intentionally left blank...
Страница 24: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C 2 7 This page intentionally left blank...
Страница 26: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C 3 9 This page intentionally left blank...
Страница 33: ...Asterion DC Multioutput Series Programming Manual 4 16 M330517 01 Rev C This page intentionally left blank...
Страница 38: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C 5 21 This page intentionally left blank...
Страница 52: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C 6 35 This page intentionally left blank...
Страница 55: ...Asterion DC Multioutput Series Programming Manual 7 38 M330517 01 Rev C This page intentionally left blank...
Страница 63: ...Asterion DC Multioutput Series Programming Manual 8 46 M330517 01 Rev C This page intentionally left blank...
Страница 73: ...Asterion DC Multioutput Series Programming Manual 9 56 M330517 01 Rev C This page intentionally left blank...
Страница 115: ...Asterion DC Multioutput Series Programming Manual 10 98 M330517 01 Rev C This page intentionally left blank...
Страница 119: ...Asterion DC Multioutput Series Programming Manual 11 102 M330517 01 Rev C This page intentionally left blank...
Страница 137: ...Asterion DC Multioutput Series Programming Manual 12 120 M330517 01 Rev C This page intentionally left blank...
Страница 145: ...Asterion DC Multioutput Series Programming Manual 13 128 M330517 01 Rev C CAL n LOCK...
Страница 159: ...Asterion DC Multioutput Series Programming Manual 13 142 M330517 01 Rev C This page intentionally left blank...
Страница 162: ...M330461 01 Rev C 14 145...