User Manual
EC1000S
California Instruments
164
If the output current or frequency suddenly increases, due, for example, to an output short circuit, the
limiter response may not be quick enough, so the output overcurrent protection function may be
triggered.
5.3.8 Output average current limiter settings
This limits the output average current.
When the output average current exceeds this setting, the output voltage is suppressed.
Table 5-17. Output Average Current Limiter Setting Range
Setting
Setting Range
Resolution
Initial Value
Output average
current limiter
100 V range
1.0 A to 10.5 A
0.1 A
10.5 A
200 V range
1.0 A to 5.3 A
0.1 A
5.3 A
Operation steps
Select
in the SET menu and set numerical values.
See
“3.4.7 Using limiter functions”
, for description of the output average value current limiter.
!
CAUTION
Содержание EC1000S
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 6: ...ii This page intentionally left blank...
Страница 10: ...User Manual EC1000S 6 9 SPECIFICATIONS Lists the specifications functions and performance of the EC1000S...
Страница 18: ...User Manual EC1000S Contents California Instruments 14 9 17 External Dimensions and Weight 286...
Страница 24: ......
Страница 32: ...User Manual EC1000S California Instruments 28...
Страница 41: ...User Manual EC1000S California Instruments 37 The product itself has a withstand voltage of 1500 V AC...
Страница 46: ......
Страница 145: ...User Manual EC1000S California Instruments 141 ENTER CANCEL...
Страница 146: ......
Страница 194: ......
Страница 217: ...User Manual EC1000S California Instruments 213 Response example 200 0...
Страница 248: ......
Страница 266: ......
Страница 274: ......