Ametek 70-0409-190 Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 

 

 
 
 

EMX-75

XX 

S

ERIES

 

 

64-C

HANNEL

 

D

IGITAL 

I

NPUT 

/

 

O

UTPUT

 

 
 

U

SER

M

ANUAL

 

 

P/N: 82-0127-022 

Released January 19, 2021

 

 

 

 
 

AMETEK Programmable Power  

9250 Brown Deer Road 

 San Diego, CA 92121, (858) 450-0085 

Содержание 70-0409-190

Страница 1: ...EMX 75XX SERIES 64 CHANNEL DIGITAL INPUT OUTPUT USER S MANUAL P N 82 0127 022 Released January 19 2021 AMETEK Programmable Power 9250 Brown Deer Road San Diego CA 92121 858 450 0085...

Страница 2: ...ecifications 11 Environmental Specifications 12 SECTION 2 13 EMX 7510 64 CHANNEL DIGITAL I O CARD 13 Measurement Performance 14 Connector Pin Signal Assignment 15 EMX 7510 Specifications 16 Theory of...

Страница 3: ...Driver Installation 36 IVI Shared Components Installation Windows Only 37 Instrument Driver Installation 37 DIRECT PCIe REGISTER CONTROL INTERFACE FOR EMX 75xx CARDS 38 Programming the Instrument 38...

Страница 4: ...uments is a trademark owned by AMETEK Inc Other trademarks registered trademarks and product names are the property of their respective owners and are used herein for identification purposes only Noti...

Страница 5: ...uyer Any warranty of AMETEK will not apply if the Buyer is in default under the Purchase Order Agreement or where the Product or any part thereof is as follows damaged by misuse accident negligence or...

Страница 6: ...ty instructions Frame or chassis ground Indicates that the product was manufactured after August 13 2005 This mark is placed in accordance with EN 50419 Marking of electrical and electronic equipment...

Страница 7: ...electric shock the grounding conductor must be connected to earth ground Operating Conditions To avoid injury electric shock or fire hazard Do not operate in wet or damp conditions Do not operate in...

Страница 8: ......

Страница 9: ...such as relays while all clamping diodes and open collector channels can be pulled up internally rather than on a per channel basis simplifying overall system cabling Isolated models are also availabl...

Страница 10: ...ent For other requirements see storage and transport restrictions in Specification TRANSPORTING INSTRUMENTS Package the module using the original factory packaging or packaging identical to the factor...

Страница 11: ...f VCLAMP VIN max 60 V Data Output Characteristics VOUT high 2 V to 60 V VOUT low 1 5 V 300mA Voltage Range Internal Voltage Source VCLAMP 3 3 V 5 0 V 12 0 V and 24 0 V User Voltage VCLAMP 2 V up to 60...

Страница 12: ...V VOUT low 1 5 V 300mA Voltage Range Internal Voltage Source VCLAMP 3 3 V 5 0 V 12 0 V and 24 0 V User Voltage VCLAMP 2 V up to 60 V Connector Type ERNI 160 Pin Modes Immediate Outputs are written vi...

Страница 13: ...an on a per channel basis Each channel can sink 300 mA and includes built in clamping diodes making this module ideal for driving and sensing external devices such as relays P2 J3 FPGA J4 PXIe Back Pa...

Страница 14: ...der test In normal mode R1 is 100 k In TTL emulation mode R1 is 499 and in LV emulation mode R1 is 330 So the pull up to VCLAMP is much stronger TTL emulation mode is available for the 3 3 V and 5 V v...

Страница 15: ...E13 DATA4 5 A14 GND_S B14 GND_S C14 GND_S D14 GND_S E14 DATA4 8 A15 DATA4 1 B15 GND_S C15 DATA4 7 D15 GND_S E15 GND_S A16 DATA4 3 B16 USER_V3 C16 DATA5 1 D16 GND_S E16 GND_S A17 DATA5 3 B17 GND_S C17...

Страница 16: ...60 V DATA OUTPUT CHARACTERISTICS VOUT high VOUT low 2 V to 60 V 1 5 V 300 mA Sink VOLTAGE RANGE Internal voltage source User 3 3 V 5 0 V 12 0 V and 24 0 V 2 V up to 60 V MODES Immediate Normal Inputs...

Страница 17: ...ls and no user voltage should be applied on those channels When direction is input data lines are pulled up to VCLAMP using 100 k resistor and user can drive their data on the channels with a VIN rang...

Страница 18: ...nt protection circuit turns off all FETs in the concerned port The over current condition must last for greater than 12 8 s before over current protection circuit is activated This is done to prevent...

Страница 19: ...RNAL RINPUT 201 k 3 7V LV Emulation 5V TTL Emulation R1A R1B R1C RUSER FIGURE 1 4 TTL LV EMULATION SOURCING CURRENT TYPICAL CONNECTION Sinking Current Typical connection P2 J3 FPGA J4 PXIe Back Panel...

Страница 20: ...is a high performance I O module with eight ports of 8 bits 64 channels each with standard TTL voltage levels Each 8 bit port may be configured as an Input or Output under program control BLOCK DIAGR...

Страница 21: ...15 GND C15 DATA4 7 D15 GND E15 GND A16 DATA4 3 B16 C16 DATA5 1 D16 GND E16 GND A17 DATA5 3 B17 GND C17 DATA5 2 D17 E17 DATA4 6 A18 DATA5 8 B18 GND C18 DATA5 4 D18 GND E18 DATA5 5 A19 GND B19 GND C19 G...

Страница 22: ...is a high performance I O module with eight ports of 8 bits 64 channels each with standard LV TTL voltage levels Each 8 bit port may be configured as an Input or Output under program control BLOCK DI...

Страница 23: ...B15 GND C15 DATA4 7 D15 GND E15 GND A16 DATA4 3 B16 C16 DATA5 1 D16 GND E16 GND A17 DATA5 3 B17 GND C17 DATA5 2 D17 E17 DATA4 6 A18 DATA5 8 B18 GND C18 DATA5 4 D18 GND E18 DATA5 5 A19 GND B19 GND C19...

Страница 24: ...D 32DO ISOLATED CHANNELS CARD The EMX 7513 is a high performance module with 32 Isolated Digital Input channels and 32 Isolated Digital Output channels BLOCK DIAGRAM FIGURE 1 2 EMX 7513 BLOCK DIAGRAM...

Страница 25: ...I_3 8 C17 DO_5 4 D17 DO_5 5 E17 DO_5 8 A18 DI_4 8 B18 DI_3 8 C18 DO_5 4 D18 DO_5 5 E18 DO_5 8 A19 DO_6 1 B19 DO_5 1 C19 DO_6 5 D19 DO_5 6 E19 DO_7 1 A20 DO_6 1 B20 DO_5 1 C20 DO_6 5 D20 DO_5 6 E20 DO_...

Страница 26: ...Index EMX 7514 64 DO ISOLATED CHANNELS CARD The EMX 7514 is a high performance module with 64 Isolated Digital Output channels BLOCK DIAGRAM FIGURE 1 3 EMX 7514 BLOCK DIAGRAM FIGURE 1 14 EMX 7514 FRO...

Страница 27: ...DO_5 3 D15 DO_4 4 E15 DO_5 7 A16 DO_4 7 B16 DO_3 7 C16 DO_5 3 D16 DO_4 4 E16 DO_5 7 A17 DO_4 8 B17 DO_3 8 C17 DO_5 4 D17 DO_5 5 E17 DO_5 8 A18 DO_4 8 B18 DO_3 8 C18 DO_5 4 D18 DO_5 5 E18 DO_5 8 A19 DO...

Страница 28: ...X Index EMX 7515 64 DI ISOLATED CHANNELS CARD The EMX 7515 is a high performance module with 64 Isolated Digital Input channels BLOCK DIAGRAM FIGURE 1 5 EMX 7515 BLOCK DIAGRAM FIGURE 1 15 EMX 7515 FRO...

Страница 29: ...7 B16 DI_3 7 C16 DI_5 3 D16 DI_4 4 E16 DI_5 7 A17 DI_4 8 B17 DI_3 8 C17 DI_5 4 D17 DI_5 5 E17 DI_5 8 A18 DI_4 8 B18 DI_3 8 C18 DI_5 4 D18 DI_5 5 E18 DI_5 8 A19 DI_6 1 B19 DI_5 1 C19 DI_6 5 D19 DI_5 6...

Страница 30: ...nel basis Each channel can sink 300 mA and includes built in clamping diodes making this module ideal for driving external devices such as relays P2 J3 FPGA J4 PXIe Back Panel conn Front panel conn DO...

Страница 31: ...ernal load presented by the unit under test In normal mode R1 is 100 k In TTL emulation mode R1 is 499 and in LV emulation mode R1 is 330 So the pull up to VCLAMP is much stronger TTL emulation mode i...

Страница 32: ...5 3 B17 GND_S C17 DATA5 2 D17 USER_V6 E17 DATA4 6 A18 DATA5 8 B18 GND_S C18 DATA5 4 D18 GND_S E18 DATA5 5 A19 GND_S B19 GND_S C19 GND_S D19 GND_S E19 DATA5 7 A20 GND_S B20 USER_V5 C20 GND_S D20 GND_S...

Страница 33: ...so need a voltage reference before data can be written this voltage is used for pulling up open drain data lines No voltage should be applied on data lines before voltage selection and during voltage...

Страница 34: ...l exhibits RC charging with a rise time of approximately 70 s with 100 k pull up resistor and about 600 ns with low impedance pull up in TTL and LV voltage configurations When a 0 is driven on channel...

Страница 35: ...onn Front panel conn DIO Output Buffer GND_S DATAx y 330 499 100 k Channel Control Over Current Detect User Voltage ESD GND_S Configuration Buffer 3V7DC 5VDC 12VDC 24VDC INT_V_0 VCLAMP USER INTERNAL 3...

Страница 36: ...APIs The IVI COM interface can be used from any programming language that supports Microsoft COM Component Object Model For Linux there is a driver that provides a C API Both Windows and Linux driver...

Страница 37: ...VI shared components can be downloaded and installed from IVI Foundation Web page www ivifoundation org FIGURE 3 1 IVI SHARED COMPONENT INSTALLATION Instrument Driver Installation If the VTEXDio instr...

Страница 38: ...r 82 0127 100_ EMX 75XX Direct PCIe ICD from DOCUMENTS AND DOWNLOAD section of respective EMX 75xx DIO Model from https www powerandtest com ate data acq platforms pxi express instruments document for...

Страница 39: ...ver in each environment 1 Visual Studio C import IviDriverTypeLib dll no_namespace import VTEXDIO dll no_namespace 2 C Add a reference to VTEXDIO dll in the project Include the following at the top of...

Страница 40: ...t main Windows driver creation CoInitialize NULL start COM layer try IVTEXDIOPtr Dio __uuidof VTEXDIO We chose to give this driver an empty options string If you have more than one DIO card in your ch...

Страница 41: ...be specified Slots 2 Just slot 2 Slots 2 EMX_75XX slot and card model Slots 2 3 Multiple slots InterchangeCheck Boolean option that enables disables IVI Interchangeability checking As implemented in t...

Страница 42: ...ified there s no OverCurrent condition Let s read some data int data Dio Normal Ports Item PORT1 Data We can also change our Polarity if we want to read the data inverted Dio Normal Ports Item PORT1 P...

Страница 43: ...e read the data back if Dio Normal Ports get_Item PORT1 LatchedOverCurrent true The port is in an OverCurrent state so we would want to take some action here We want to check the Latched OverCurrent b...

Страница 44: ...The Configure call lets us set all the values for a particular port quickly Here we will configure the port with a direction of Output a Polarity of Normal a VoltageSource of User and a voltage of 5V...

Страница 45: ...ous ways to search the IP address and other network configuration parameters of the instrument The easiest method is to refer to the embedded display on the instrument and use the menu key to navigate...

Страница 46: ...ead use Auto IP Determining the Auto IP address has been provided in the EMX 75XX Series User s Manual Other discovery methods such as VXI 11 can be used as well COMMON ISSUES Although Ethernet is an...

Страница 47: ...bles echo request respond for ping ICMPv6 ICMP Optional Typically enables echo request respond for ping also SLAAC for IPv6 addresses RDDNS Arp Arp Used to confirm address assignments DHCPv4 67 68 UDP...

Страница 48: ...entered changes Leaving a page before submitting any changes has the effect of canceling the changes leaving the instrument in its original state Navigation through a parameter screen is done with the...

Страница 49: ...is an example of an action page Entry This type of page displays and accepts changes to the configuration of the instrument The Time Configuration page is an example of an entry page Use of the entry...

Страница 50: ...of this discussion will focus on the EMX 75XX soft front panel For more information on other EMX 7510 soft front panel elements please refer to the EMX 75XX Series User s Manual EMX 75XX Soft Front Pa...

Страница 51: ...4 5 EMX 75XX SOFT FRONT PANEL NORMAL MODE Port Configuration Fields For each Port the following settings can be configured Figure 4 6 Port Configuration Fields Data Indicators The LED indicators in e...

Страница 52: ...1 0 are not voltage values but correlate to LV emulation and TTL emulation respectively hence if the user sets that value the direction will be changed to Output automatically Direction Sets the port...

Страница 53: ...Source Sink 60V max static only card It supports all the features like Direction change Polarity Voltage source selection Port Read Write Over Current Latched Over Current Reset Latched Over Current...

Страница 54: ...3 3V LV TTL static only card It supports features like Direction change Polarity Port Read Write EMX 7513 FIGURE 4 11 EMX 7513 SFP EMX 7513 is a 32 Digital Input 32 Digital Output channel Source Sink...

Страница 55: ...t CH Computer GND isolation 60V Source Sink Static only card It only supports features like Polarity change Port Read Write EMX 7515 FIGURE 4 13 EMX 7515 SFP EMX 7515 is a 64 channel Digital Input CH...

Страница 56: ...9 SFP EMX 7519 is a 64 channel Digital Output Source Sink 60V max static only card Except Direction change it supports all the features like Polarity Voltage source selection Port Read Write Over Curr...

Страница 57: ...e flash components and whether the user can perform writable operation on them or not Component Volatile Contains User Writeable Clear Procedure Models IC NOR FLASH 256Mb 8P WSON Part no 19 0123 000A...

Страница 58: ...PPENDIX B The following table provide MTBF of EMX 75xx Models Sl no Model MTBF 40 C Hours 1 EMX 7510 312 500 2 EMX 7511 312 500 3 EMX 7512 312 500 4 EMX 7513 312 500 5 EMX 7514 312 500 6 EMX 7515 312...

Страница 59: ...ber Manufacturer Part Number 52 0109 000R includes 100 crimp pins ERNI 234064 MATING CONNECTOR VTI Part Number Manufacturer Part Number 27 0088 160 one per board ERNI 024070 CRIMP PIN VTI Part Number...

Страница 60: ...A8 T96 E1 T136 GND_S B30 T17 DATA1 8 C3 T57 GND_S A7 T97 DATA7 5 E26 T137 GND_S C31 T18 GND_S B3 T58 DATA2 4 A6 T98 GND_S D26 T138 GND_C B31 T19 GND_S C2 T59 DATA1 3 A5 T99 DATA6 7 E24 T139 GND_S B29...

Страница 61: ...GND_C B31 T19 GND C2 T59 DATA1 3 A5 T99 DATA6 7 E24 T139 GND B29 T20 GND B2 T60 DATA1 1 A4 T100 D24 T140 DATA8 1 C29 T21 DATA1 2 C4 T61 DATA1 4 A3 T101 GND E27 T141 G B28 T22 GND B4 T62 GND A2 T102 G...

Страница 62: ...D26 T138 B31 T19 C2 T59 DI_1 1 A5 T99 E24 T139 DO_8 2 B29 T20 B2 T60 A4 T100 DO_6 8 D24 T140 DO_8 5 C29 T21 DI_1 5 C4 T61 A3 T101 E27 T141 DO_7 5 B28 T22 B4 T62 A2 T102 D27 T142 DO_8 3 C28 T23 DI_1 6...

Страница 63: ...8 1 D26 T138 B31 T19 C2 T59 DO_1 1 A5 T99 E24 T139 DO_8 2 B29 T20 B2 T60 A4 T100 DO_6 8 D24 T140 DO_8 5 C29 T21 DO_1 5 C4 T61 A3 T101 E27 T141 DO_7 5 B28 T22 B4 T62 A2 T102 D27 T142 DO_8 3 C28 T23 DO_...

Страница 64: ...D26 T138 B31 T19 C2 T59 DI_1 1 A5 T99 E24 T139 DI_8 2 B29 T20 B2 T60 A4 T100 DI_6 8 D24 T140 DI_8 5 C29 T21 DI_1 5 C4 T61 A3 T101 E27 T141 DI_7 5 B28 T22 B4 T62 A2 T102 D27 T142 DI_8 3 C28 T23 DI_1 6...

Отзывы: