Ametek Land ADT Скачать руководство пользователя страница 1

Aluminium Die Thermometer

Copyright © 2003 - 2015 Land Instruments International

User Guide

Issue 4

21 April 2015 

Publication N

o

 198.65 

 

Language: English

Содержание ADT

Страница 1: ...Aluminium Die Thermometer Copyright 2003 2015 Land Instruments International User Guide Issue 4 21 April 2015 Publication No 198 65 Language English...

Страница 2: ...e user documentation supplied before installing and operating the equipment The safety of any system incorporating this equipment is the responsibility of the assembler Protective Clothing Face and Ey...

Страница 3: ...nstruments International is approved to BS EN ISO 9001 for the design manufacture and on site servicing of combustion environmental monitoring and non contact temperature measuring instrumentation App...

Страница 4: ...Thermometer User Guide...

Страница 5: ...4 3 Installation 5 3 1 Positioning the Optic Head 6 3 2 Installing the Optic Head 7 3 3 Installing the Lightguide 8 3 4 Positioning the Thermometer 8 3 5 Electrical Connections 9 3 6 Electrical Connec...

Страница 6: ...Thermometer User Guide...

Страница 7: ...e used maintained and serviced by suitably trained personnel capable of safely following the procedures and guidelines given in these instructions 1 3 About the ADT Thermometer The ADT Thermometer is...

Страница 8: ...have been supplied The packaging should contain the following items ADT Thermometer Installation Guide ADT Thermometer User Guide A binder for all user documentation ADT Thermometer fitted with Fibrop...

Страница 9: ...ce of the thermometer above the lightguide connector Make a note of the Instrument type and thermometer serial number from this detail label as this information will be required when configuring the t...

Страница 10: ...atability 1K Absolute 0 25 K 1K Stability Temperature 0 2 ambient Time 2 C 4 F per year Vibration 3G any axis 10 to 300Hz Humidity 0 to 99 non condensing Sealing IP65 Ambient temperature Optic head Li...

Страница 11: ...accessories 3 Installation Mounting pad 2 holes 1 4in BSW 7 0 3 deep on 25 1 0 centres Recommended orientation of thermometer to prevent the ingress of water and a build up of dirt etc on electrical...

Страница 12: ...bles Section 4 2 The thermometer s view of the target area must not be obstructed 2 Ensure that the angle between the optic head s line of sight and the target area is as near to 90 as possible Howeve...

Страница 13: ...e optic head M22 x 1 5P thread Clamp nuts each side of plate Fig 3 a Mounting the Optic Head into a Plate 265003a To mount the optic head into Fibroptic thermometer mountings refer to Fig 3 b 1 Screw...

Страница 14: ...must be mounted in a special cooling heating jacket available from Land Instruments 2 If the thermometer is to be used in conjunction with a protection jacket refer to the installation guide provided...

Страница 15: ...o the thermometer socket see Fig 5 Align the red marker near the lugs of the plug with the red marker located above the keyway in the thermometer socket Push the plug into the socket ensuring that the...

Страница 16: ...Page 10 Thermometer User Guide ADT Fig 5 Connection of a 6 way Plug to the Thermometer Socket 265005 Keyway Locking Sleeve Lugs Red Markers...

Страница 17: ...reen T T E Screen V V E 4 to 20mA linear temperature signal drive 4 to 20mA linear temperature signal return 4 to 20mA emissivity signal drive Screen 24 to 30V d c power positive 24 to 30V d c power n...

Страница 18: ...ocal distance of this type of optic head is 00mm 19 6in 4 2 Optic Head A50 Field of View 22 1 No Spacer 10 3mm 0 41in Target Diameter Target Distance 0mm 0in 12 8mm 0 50in 100mm 3 94in 15 4mm 0 61in 2...

Страница 19: ...garding the emissivity of the target in your measurement application contact Land Instruments International for advice 5 1 Die Emissivity The ADT Thermometer is a designated instrument used primarily...

Страница 20: ...a soft cloth and a proprietary cleaning fluid Take care not to scratch or mark the lens 6 2 Air Supply If an air purge system is utilised to keep the Fibroptic Thermometer lens free from contaminatio...

Страница 21: ...truments based on System 4 UNO thermometers accessories and mountings and special instruments based on UNO Application dedicated processors based on LANDMARK Graphic ABTS S and ABTS U FTS VDT S and VD...

Страница 22: ...ide the Ambient Temperature Humidity and Vibration rating of the product environmental contamination solvent vapours deposition of airborne contamination cooling liquids of non neutral pH etc overheat...

Отзывы: