background image

5. 

 NEVER put substances that can ignite explosively 

inside the unit, since even small explosions in confined 
areas can blow out the glass. 

6.

   This unit has an airwash system, designed to 

reduce deposits on the glass. 

GLASS AND GASKET 

REPLACEMENT 

The glass can be broken only with a hit and the 
replacement procedure is the same that gasket 
replacement. 

After extensive use, the sealing material which 
provides glass and door seal may need to be replaced 
if it does not sustain its resilience.  Inspect the glass 
and door seal periodically to ensure proper seal. If the 
gaskets become frayed or worn, replace immediately.  
Contact your dealer or Technical Support at 800-444-
6742 for approved replacement parts. 

The following steps should be followed for 
replacement of the 

glass and glass gasket

1. 

Ensure that the appliance is not in operation, and is 

thoroughly cooled. 

2.

 Remove the screws and glass clips. 

3. 

Lift glass out from glass clips. 

4. 

Remove the old gasket, and clean/replace the 

glass.

5. 

 If you need to replace the glass, you must to do 

with care avoiding cutting edges and replacing with 
an proper glass. See GLASS CARE point.

6. 

  Replace the gasket, starting at the corner of the 

glass and working along the edges.  Be sure to center 
the gasket channel on the glass. Trim the gasket to 
length and butt the ends together. 

7. 

Replace the glass in the door, being sure not to 

over-tighten the screw and clip. 

You may order parts and options by calling 800-444-
6742

The following steps should be followed for 
replacement of the 

door gasket

1. 

 Ensure the appliance is not in operation and is 

thoroughly cooled. 

2.

  Remove the old door gasket and clean the gasket 

channel. 

3.

 Using an approved high-temperature gasket 

cement, apply a thin coat in the bottom of the 
channel. 

4. 

 Starting at the hinge side of the door, work into the 

channel around the door unit, trim to length and butt 
the ends together. 

5. 

 Close the door and allow three to four hours for the 

cement to set before restarting any fire. 

Door Assembly 

AMESTI R 450

COLD HANDLE AND

AIR INLET CONTROL

The manufacturer includes a steel handle with each 
fireplace. This handle must be used to open and close 
the door, and to move the air control lever. 

The handle must be stored away from the fireplace 
to prevent that it gets hot. Never leave the handle 
installed in the door latch, while operating the 
fireplace.

The Air Inlet Control reaches high temperatures. Must 
be operated with the cold handle to avoid burns

 (see 

picture)

Illustration 6: Air Inlet Control

Control Settings

Burn rate

Inlet Air Setting

Low

Fully Closed

Med. Low

¼ Open

Med. High

¾ Open

High

Fully Open

CREOSOTE 

When wood is burned slowly, it produces tar and 
other organic vapors. These combine with moisture 
to form creosote. Creosote vapors condense in the 
relatively cool chimney flue of a slow - burning fire 
– as a result, creosote residue accumulates on the 
lining of the flue.  If ignited, this creosote makes an 
extremely hot fire. The chimney should be inspected 
on a regular basis during the heating season, to 
determine if a creosote build-up has accumulated.  If 
it has, the creosote should be removed to reduce the 
risk of chimney fire. 

WARNING:  THINGS TO REMEMBER IN CASE OF A 
CHIMNEY FIRE:

1. CLOSE AIR INLET CONTROL 
2. CALL THE FIRE DEPARTMENT

WAYS TO PREVENT AND KEEP 

UNIT FREE OF CREOSOTE 

1.

 Burn with the air control fully open for several 

minutes at numerous intervals throughout each day 
during the heating season, being careful not to over-
fire the unit.  This should remove the slight film of 
creosote that accumulates during low burn periods. 

2. 

Burn the stove with the draft control fully open for 

approximately 20-30 minutes every time you apply 
fresh wood. This allows wood to achieve the charcoal 
stage faster, and burns wood vapors which might 
otherwise be deposited within the system.
 

3.

 BURN ONLY SEASONED WOOD.  Avoid burning wet 

or green wood.  Seasoned wood is wood that has 
been dried for at least one year. 

4. 

A small, hot fire is preferable to a large, smoldering 

one that can deposit creosote within the system. 

5. 

Establish a routine for fuel, wood burner and firing 

technique.  Check daily for creosote build¬up until 
experience shows you how often you need to clean 
to be safe.  Keep in mind that the hotter the fire, the 
less creosote is deposited, and weekly cleanings may 

14

15

Содержание R 450

Страница 1: ...h July 1990 Particulate emission standards Tested to UL 1482 2000 ULC S627 2000 OWNER S MANUAL MODEL NUMBER AMESTI R 450 Thank you for purchasing this product from a fine line of heating equipment fro...

Страница 2: ...ite at www amesti cl for helpful information frequently asked questions parts accessory orders and more Technical Support 800 444 6742 OPERATION WHY THE CORRECT FLUE SIZE IS IMPORTANT 6 Draft is the f...

Страница 3: ...amage caused by the malfunction of a stove due to improper installation Do not use makeshift methods or material which may compromise the installation The manufacturer will not be responsible for an a...

Страница 4: ...or a single wall sheet steel chimney connector of minimum 24 gauge thickness with a minimum 2 in air space between the outer wall of chimney section and combustibles Minimum length of chimney section...

Страница 5: ...k up you will need wall protection at least twelve inches 12 above the wall thimble i R value is given no conversion is needed ii k factor is given with a required thickness T in inches R 1 k xT iii C...

Страница 6: ...tallation rigid 10 Maintain the required diameter flue for the entire installation 11 If you are connecting the stove to an old masonry flue besuretohaveitinspectedforcracksandgeneral condition Relini...

Страница 7: ...nlet control until the fire is well established approximately 20 minutes being careful not to over fire 8 Readjust the air inlet control to the desired burn rate If excessive smoke fills the firebox o...

Страница 8: ...ufacturer includes a steel handle with each fireplace This handle must be used to open and close the door and to move the air control lever The handle must be stored away from the fireplace to prevent...

Страница 9: ...60 of the fuel value of dry seasoned wood will deposit creosote on the inside of the stove and along to inside of the chimney 4 What does dry seasoned wood mean and what is considered to be hardwood...

Страница 10: ...his fireplace referring to the materials and manufacturing will be free of defects at the time of purchase The manufacturer extends the following warranties Five Year Period Steel and welded joints in...

Страница 11: ...____ Dealer store Other ____________________________________________________ Where did you receive information about our product Please check one ___ Rec d info via phone ___ Dealer Name of dealer ___...

Страница 12: ...16 Visitez notre site web www amesti cl pour des informations utiles questions fr quentes commande de pi ces accessoires et plus Assistance Technique 800 444 6742 FONCTIONNEMENT POURQUOI UNE TAILLECO...

Страница 13: ...nsabledesaccidents dus au raccordement de l unit un syst me de chemin e d fectueux APPLICATIONS D INSTALLATION Illustration 1 Si vous rencontrez de tels probl mes consultez un expert local en chemin e...

Страница 14: ...vantde passage pour le connecteur mural de la chemin e en t le d acier de calibre 24 minimum d paisseur avec un espace d air de deux pouces 2 minimum entre la paroi ext rieure de la section de la chem...

Страница 15: ...murale d au moins douze pouces 12 au dessus de la cartouche murale i la valeur R est donn e pas de conversion requise ii le facteur k est donn avec une paisseur T requise en pouces R 1 k xT iii le fa...

Страница 16: ...c un rev tement en acier inoxydable peut tre requis 12 Il est recommand que pas plus de deux coudes de 90 soient utilis s dans l installation du conduit Plus de deux coudes de 90 pourraient diminuer l...

Страница 17: ...u soit bien tabli environ 20 minutes faites attention la surchauffe 8 R ajustez l arriv e d air jusqu la vitesse de combustion d sir e Si un exc s de fum e remplit le foyer ouvrez l g rement l arriv e...

Страница 18: ...aporteetlaissezlecimentprendrependant trois quatre heures avant de rallumer un feu Assemblage de la Porte AMESTI R 450 POIGNEE FROIDE ET CONTROLE D ARRIVEE D AIR Le fabricant inclut une poign e d acie...

Страница 19: ...utiliser comme bois de chauffage Du bois sec et dur doit tre utilis Evitez les bois verts ou non s ch s Le bois vert en plus de ne bruler qu 60 de la valeur nerg tique des bois secs d posera de la cr...

Страница 20: ...PROPRIETAIRE ORIGINAL AMESTI garantit que toutes les pi ces de ce po le se r f rant des mat riaux et de fabrication seront exemptes de d fauts au moment de l achat Le fabricant tend les garanties suiv...

Страница 21: ...reporter l autocollant sur l int rieur des pieds du foyer pour compl ter cette partie Num ro de mod le_________________________ Date d achat _____________________________ Prix d achat ________________...

Страница 22: ......

Отзывы: