MRO 3 & 4 MANUAL
1
98-0140
Rev. F
SECTION 1 GENERAL INFORMATION
1.1
INTRODUCTION
Congratulations on your decision to use the MRO system! The MRO is a stand alone water
treatment system for use in hemodialysis applications. It is designed to pretreat and purify
water resulting in product water that meets or exceeds ANSI/AAMI RD62 requirements for
use in making dialysate for hemodialysis.
All models of the MRO are shipped completely assembled with required and optional water
treatment components. The model that you purchased was selected for the volume of water
needed and the analysis of your input water. This Operation Manual was written for the
MRO3 and MRO4 models.
Your MRO system was thoroughly tested and in excellent condition when it was shipped to
you. However, because damage during shipment is possible, please unpack and carefully
inspect the MRO as soon as you receive it. Please notify AmeriWater
®
if any problems are
encountered.
The initials “PAA” are used occasionally throughout this manual to generically represent the
hydrogen peroxide/peroxyacetic acid solution that is to be used for disinfection. Peracidin
®
is
an example of this solution. The caution on the front panel of the MRO that states “Use only
PAA/Use no substitutes” means that any of these products are acceptable. Do not attempt to
use anything other than hydrogen peroxide/peroxyacetic acid disinfecting solution.
Please read the Operations Manual before using the system.
Contact AmeriWater
Customer Service with any questions at 1-800-535-5585 Monday through Friday 8:00 a.m. to
5:00 p.m. eastern standard time. For after hours emergencies call 1-800-535-5585 and
follow the instructions on the recorded message. Our on-call technician will return your call
as soon as possible.
NOTE: This entire Operations Manual should be read before operating or servicing the
system. This Operations Manual should then be kept near the system and used as a
reference and troubleshooting guide.
WARNING: This Reverse Osmosis System (RO) contains a preservative solution to
prevent microbiological growth and freezing. Discard all product water for
at least two hours of operation before placing the RO in service.
CAUTION:
No person should attempt to operate or service the AmeriWater MRO
without prior authorization, instruction, and training from AmeriWater
and/or your medical facility director.
1.2
RESTRICTION ON USE
Federal law restricts this device for sale by or on the order of a physician (medical director)
for use as a water treatment device for hemodialysis.
Содержание MRO3
Страница 8: ...MRO 3 4 MANUAL 5 98 0140 Rev F SECTION 3 COMPONENTS AND SCHEMATICS 3 1 EXTERNAL FRONT VIEW...
Страница 10: ...MRO 3 4 MANUAL 7 98 0140 Rev F 3 2 INTERNAL REAR VIEW...
Страница 12: ...MRO 3 4 MANUAL 9 98 0140 Rev F 3 3 ELECTRICAL DIAGRAM MRO3 MRO4...
Страница 13: ...MRO 3 4 MANUAL 10 98 0140 Rev F 3 4 FLUID DIAGRAM MRO3 MRO4...
Страница 34: ...MRO 3 4 MANUAL 31 98 0140 Rev F FIGURE 6 2...
Страница 35: ...MRO 3 4 MANUAL 32 98 0140 Rev F FIGURE 6 3...
Страница 52: ...MRO 3 4 MANUAL 49 98 0140 Rev F SECTION 11 MRO3 4 SPARE PARTS LISTING...
Страница 53: ...MRO 3 4 MANUAL 50 98 0140 Rev F...