American ART-258 Скачать руководство пользователя страница 1

1.0  IMPORTANT RECEIVING INSTRUCTIONS

Visually inspect all components for shipping damage.

Please

contact American Rescue Technology products if damage has
occurred.

SAFETY FIRST

2.0  SAFETY ISSUES

American Rescue Technology products are designed and
manufactured to provide excellent service when used for their
intended purpose. Operator safety is a major consideration in the
product design and operator manuals are provided to promote

their safe use. The company urges all users to read the instruction
manual and to seek operating instructions from qualified
instructors before attempting to use the products.

Although most safety precautions are addressed in factory
authorized training programs as well as throughout this manual,
pay particular attention to the following:

• Power units and tools should be operated by qualified

personnel only.

• Be sure to follow all maintenance procedures and to use only

factory authorized service parts.

Instruction Manual

5.5 HP Honda Gas Power Unit

ART-258

L2514

Rev. O

09/01

Specifications

ART-258

Operating Pressure

350 bar (5,000 psi maximum)

Valve Type

(2) Dump

Motor

Honda GXV 160 5.5 HP (4,1 kW), 4 cycle
See Honda GXV 160 Owner’s Manual supplied with pump.

Sound Level

80 dBA at 1 m (3 ft) at no load

Flow Rate

7,5 1/min (460 in

3

/min) at 0 bar (0 psi)

1,6 1/min (100 in

3

/min) at 350 bar (5,000 psi)

Unloading Pressure

110 bar (1,600 psi)

Reservoir Capacity

8 Liter (2.1 gallons)

Dry Weight

44 kg (97 lbs) 

Recommended Hydraulic Fluid

American Rescue Technology Fire Resistant Phosphate Ester Fluid

Содержание ART-258

Страница 1: ... in factory authorized training programs as well as throughout this manual pay particular attention to the following Power units and tools should be operated by qualified personnel only Be sure to follow all maintenance procedures and to use only factory authorized service parts Instruction Manual 5 5 HP Honda Gas Power Unit ART 258 L2514 Rev O 09 01 Specifications ART 258 Operating Pressure 350 b...

Страница 2: ... port on the top of the reservoir See illustration below 1 Remove shipping plug 1 2 Install the fluid level gauge that was shipped with the power unit 2 Figure 1 CAUTION The fluid level gauge acts as the vent for the reservoir and must be installed whenever you run the power unit Never run the power unit with the shipping plug installed This will cause damage to the pumping mechanism 3 2 Check Flu...

Страница 3: ...d or otherwise damaged it must be replaced Damaged hoses may rupture at high pressure causing personal injury 5 0 MAINTENANCE 5 1 Check Fluid IMPORTANT Observe local ordinances when disposing of used fluid Completely drain the reservoir after every 100 hours of operations Refill with new hydraulic fluid If power unit is used infrequently change the fluid once a year Procedure see Figure 5 1 Positi...

Страница 4: ...omponent Rescue tool will not Valve not in the pressure position Move valve lever firmly into pressure position open or close Flow to tool blocked by loose Release pressure and turn off unit Check that coupler connection all couplers are completely connected and hand tightened Fluid level too low Fill reservoir to proper level Filter screens clogged Remove the reservoir Clean or replace filter scr...

Отзывы: