HIGH TEMPERATURE LIMIT CONTROLS (ECO)

Both  the  ELECTRONIC  CONTROL  and  SURFACE  MOUNT 

CONTROL  model  water  heaters  are  equipped  with  one  or 

more  ECO  (energy  cut  out)  non  adjustable  high  temperature 

limit control(s). An ECO is a normally closed switch that opens 

(activates) on a rise in temperature. If the ECO switch contacts 

open  (activate)  due  to  abnormally  high  water  temperatures  it 

will lock-out and disable further heating element operation. It is 

important that a qualified service agent be contacted to determine 

the reason for the ECO activation before resetting the ECO. Once 

the reason has been determined and corrected the ECO(s) can 

be reset as follows:

SURFACE MOUNT CONTROL MODELS

Surface Mount Control models have multiple surface mounted 

Thermostat/ECO combination controls. One for each installed 

heating element - see the Surface Mount Control wiring diagrams 

in this manual. The ECO high temperature limit switch contacts 

on each control will open when the tank temperature reaches 

approximately 200°F/93°C. When the ECO switch contacts open 

(activate) voltage to ONE heating element ONLY is terminated to 

prevent further heating operation of that element. Voltage may 

still be present at other heating elements and they may still be 

heating the water.
The ECO is a manual reset switch. Should one or more ECO 

activate,  the  tank  temperature  must  drop  below  120°F/49°C 

before an ECO can be reset. To manually reset an ECO:

1. 

Disconnect the power supply to the water heater.

2. 

Allow the tank temperature to cool below 120°F/49°C.

3. 

Remove the front control cover from the effected control(s).

4. 

Press the manual reset button on each of the effected controls.

Once the control(s) has been reset the control cover should be 

replaced prior to restoring power to the water heater.

ELECTRONIC CONTROL MODELS

The  ECO  high  temperature  limit  switch  is  located  inside  the 

immersion Temperature Probe (two red wires) on ELECTRONIC 

CONTROL models. The ECO switch contacts will open when the 

water  temperature  reaches  approximately  202°F/94°C.  When 

the ECO switch contacts open (activate) the electronic control 

system locks out and displays a Fault message. Voltage to the 

contactor coils and heating elements is terminated to prevent 

further heating operation.

Should the ECO activate, the water temperature must drop below 

140°F/60°C before the control system can be reset. Once the 

water temperature has cooled below this point the power supply 

to the water heater must be turned off and on again to reset the 

control system.

THERMOSTAT CONTROLS

The water heaters covered in this instruction manual are equipped 

with adjustable thermostat controls to control water temperature. 

Hot water temperatures required for automatic dishwasher and 

laundry use can cause scald burns resulting in serious personal 

injury  and/or  death.  The  temperature  at  which  injury  occurs 

varies  with  the  person’s  age  and  duration  of  exposure. The 

slower response time of children, the elderly or disabled persons 

increases the hazards to them. Never allow small children to use 

a hot water tap or draw their own bath water. Never leave a child 

or disabled person unattended in a bathtub or shower.
The water heater should be located in an area where the general 

public does not have access to set temperatures.
Setting the water heater temperatures at 120°F will reduce the 

risk  of  scalds.  Some  States  require  settings  at  specific  lower 

temperatures.

THERMOSTAT SETTINGS - SURFACE MOUNT CONTROL 

These models have multiple thermostat/ECO combination controls 

one for each heating element installed. These thermostats are 

set from the factory at 140°F/60°C. Set the thermostat dial at the 

lowest setting which produces an acceptable hot water supply. 

This will always give the most energy efficient operation.
The water heater is supplied with thermostats that may come from 

different manufactures and have different temperature indications 

as described below.

THERMODISC

Thermodisc  thermostats  are  adjustable  from  approximately 

120°F (49°C) (lowest setting) to 181°F (83°C) (highest setting) 

see 

Figure 13

. These thermostats are set from the factory at 

approximately the 140°F (60°C) setting. The over temperature 

device  (ECO  high  limit)  attached  to  each  thermostat  has  a 

manual reset.

APCOM THERMOSTATS 

Apcom thermostats have three designated set points; LO, MED 

and HI. See 

Figure 14

.The approximate equivalent temperatures 

for these three settings are: LO = 140°F (60°C), MED = 160°F 

(71°C) and HI = 181°F (83°C). These thermostats are set from the 

factory at the Low 140°F (60°C) setting.  The over temperature 

device (ECO high limit) attached to each thermostat has a manual 

reset setting. 

APCOM

   INC

40A 120-277 VAC

25A.480 VAC

  125VA.PT.DTY.

   120-480 VAC

MED

LO

HI

MODE

L

WH19HC

        30A 120-250 VAC

             22A 277 VAC

        12.5A 480VAC

125 VA.PT.DTY. 120-480 VAC

Figure 13. Thermodisc 

Thermostat Controls

Figure 14. APCOM Thermostat 

Controls

Table 5

  shows  the  approximate  time-to-burn  relationship  for 

normal adult skin.

Table 5. Time to Burn Relationship for Normal Adult Skin

Water 

Temperature °F

Time for 1st Degree Burn  

(Less Severe Burns)

Time for Permanent 

Burns 2nd & 3rd Degree  

(Most Severe Burns)

110

(normal shower temp.)

116

(pain threshold)

116

35 minutes

45 minutes

122

1 minute

5 minutes

TEMPERATURE REGULATION

Содержание 120 series

Страница 1: ...CE MAINTENANCE LIMITED WARRANTY Instruction Manual PRINTED 0917 OPTIONAL Thank you for buying this energy efficient water heater We appreciate your confidence in our products PLACE THESE INSTRUCTIONS...

Страница 2: ...situation which if not avoided could result in minor or moderate injury CAUTION CAUTION indicates a potentially hazardous situation which if not avoided could result in minor or moderate injury All sa...

Страница 3: ...be run with the circuit conductors and connected to the equipment grounding terminal or lead on the water heater HYDROGEN GAS FLAMMABLE Hydrogen gas can be produced in a hot water system served by thi...

Страница 4: ...ING DIAGRAMS 41 PIPING DIAGRAMS 47 MANIFOLD KITS 49 NOTES 50 NOTES 51 SAFE INSTALLATION USE AND SERVICE 2 GENERAL SAFETY INFORMATION 3 Precautions 3 Hydrogen Gas Flammable 3 INTRODUCTION 5 Preparing f...

Страница 5: ...ts of the heater are identified on pages 7 8 The model and rating plate on page 6 interprets certain markings into useful information Both of these references should be used to identify the heater its...

Страница 6: ...51 47 44 18 61 434 246 184 148 123 105 92 82 74 67 61 57 53 24 81 912 328 246 197 164 140 123 109 98 89 82 76 70 27 92 151 369 276 221 184 158 138 123 111 101 92 85 79 30 102 390 410 307 246 205 176...

Страница 7: ...by Underwriters Laboratories Inc MODEL AND RATING LISTED 22U1 No OF WATTS PHASE VOLTS AC ELEMENTS EACH RATED MEASURED WATTS COMMERCIAL STORAGE TANK WATER HEATER MODEL NUMBER SERIAL NUMBER ITEM ID PART...

Страница 8: ...8 FEATURES AND COMPONENTS Figure 3 Electronic Control Models...

Страница 9: ...9 FEATURES AND COMPONENTS Figure 4 Surface Mount Control Models...

Страница 10: ...er should be located in an area where leakage of the tank or connections will not result in damage to the area adjacent to the heater or to lower floors of the structure Close to the point of major ho...

Страница 11: ...imum water temperature at the hot water tap then you must take special precautions In addition to using the lowest possible temperature setting that satisfies your hot water needs a means such as a MI...

Страница 12: ...ly operated at least once a year Caution should be taken to ensure that 1 no one is in front of or around the outlet of the temperature pressure relief valve discharge line and 2 the water manually di...

Страница 13: ...r 30 C multiply the ampacities shown above by the appropriate correction factor to determine the maximum allowable load current Ambient Temp F 1 Not more than three conductors in raceway cable or eart...

Страница 14: ...volt rating Do not substitute fuses of a different rating Sequence of Operation 1 When the control is powered the UIM should display model information water temperature Operating Set Point heating st...

Страница 15: ...15 WIRING DIAGRAMS Figure 8 CCB Central Control Board Control Circuit Diagram Electronic Control Models...

Страница 16: ...he heater circuits and includes wiring diagrams All heater circuits are designed for 60 50 hertz alternating current The water heater circuit wiring is 12 AWG AWM or TEW type rated 600 volts 105 C Fus...

Страница 17: ...es to terminal L2 with red wires 4 Connect incoming power to terminals L1 and L2 CONVERSION TO THREE PHASE When heater is shipped for connection to a single phase electrical service it may be connecte...

Страница 18: ...s the heater circuits and includes wiring diagrams All heater circuits are designed for 60 50 hertz alternating current The water heater circuit wiring is 12 AWG AWM or TEW type rated 600 volts 105 C...

Страница 19: ...Disconnect all red wires from terminal L3 4 Connect all red wires to terminal L2 with yellow wires 5 Connect incoming power to terminals L1 and L2 CONVERSION TO THREE PHASE When heater is shipped for...

Страница 20: ...odels only 4 Turn on the electrical disconnect switch 5 Observe the operation of the electrical components during the first heating cycle Use care as the electrical circuits are energized 6 Close the...

Страница 21: ...ystem THERMOSTAT CONTROLS The water heaters covered in this instruction manual are equipped with adjustable thermostat controls to control water temperature Hot water temperatures required for automat...

Страница 22: ...me periods Helps reduce operating costs during unoccupied or peak demand periods Linear Sequencing Banks of heating elements 3 elements per bank are energized according to adjustable 1 to 20 different...

Страница 23: ...is a call for heat present and the control system has initiated heating operation Heating elements icon for a water heater equipped with 1 Bank of heating elements Each circle repre sents one heating...

Страница 24: ...moni tored water heater functions and components are displayed in this menu Economy Mode Setup Seven day 24 hour time clock with temperature set back capability to reduce operating costs during unoc c...

Страница 25: ...ision of temperature control in the storage tank and at points of use This feature can also be used to compensate for building recirculation loops hot water returning to the storage tank that may caus...

Страница 26: ...relay coil to either circuit ELEMENT BANK ON Displays the on off status of each Bank of heating elements Yes On No Off ALARM CONDITION Displays the status of the user definable Alarm Output function...

Страница 27: ...underneath MENU to enter the Main Menu Notice how the text above the Operational Buttons on the display changes as you navigate through the various menus and screens Use the Up Down buttons to select...

Страница 28: ...changes to ACCEPT CANCEL when the adjustment mode is activated and how the current setting is outlined rather than highlighted in black Press the Operational Button underneath ACCEPT to enter and con...

Страница 29: ...the Up Down and CHANGE buttons to enter the Mon sub menu Use the Up Down buttons to select highlight in black the Normal Operation Between setting Press the Operational Button underneath SELECT to cha...

Страница 30: ...en current tank temperature drops below programmable Alarm SP Fault or Alert Used for external notification whenever a Fault or Alert condition is active Fault Used for notification whenever a Fault c...

Страница 31: ...splays non adjustable operational information The control system records and stores the last 9 Fault and Alert messages in chronological order in this menu The most recent will be at the top of the li...

Страница 32: ...ry default settings have been restored Press the Operational Button underneath BACK to exit the Restore Factory Defaults menu GENERAL Periodically the drain valve should be opened and the water allowe...

Страница 33: ...om water system Check for any leaks and immediately correct any if found 7 Restart the water heater as directed in this manual See the Repair Parts Illustration for anode rod location FLUSHING THE WAT...

Страница 34: ...eans Lime scale dissolvents will not remove these types of scale which are occasionally encountered Call the toll free phone number on the back cover of this Instruction Manual to purchase UN LIME and...

Страница 35: ...are normal however the tank bottom and elements should be cleaned See the Maintenance section of this manual 2 Some of the electrical components of the water heater make sounds which are normal Conta...

Страница 36: ...ll element with new gasket Condensation and dripping may appear on pipes when inlet water temperature is low Pipe fitting may be leaking All water which appears at the heater bottom or on the surround...

Страница 37: ...ELECTRIC 1 UNIT LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL PORT BALL VALVE TEMPERATURE GAGE WATER FLOW SWITCH CHECK VALVE WARNI...

Страница 38: ...hermostat should be set 5 degrees F higher than the Tank Temperature Control COMMERCIAL ELECTRIC 1 UNIT WITH VERTICAL STORAGE TANK LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCUL...

Страница 39: ...g thermostat should be set 5 degrees F higher than the Tank Temperature Control COMMERCIAL ELECTRIC 1 UNIT WITH HORIZONTAL STORAGE TANK LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE C...

Страница 40: ...LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL PORT BALL VALVE TEMPERATURE GAGE WATER FLOW SWITCH CHECK VALVE WARNING THIS DRAWING...

Страница 41: ...5 degrees F higher than the Tank Temperature Control COMMERCIAL ELECTRIC 2 UNITS WITH VERTICAL STORAGE TANK LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERA...

Страница 42: ...et 5 degrees F higher than the Tank Temperature Control COMMERCIAL ELECTRIC 2 UNITS WITH HORIZONTAL STORAGE TANK LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TE...

Страница 43: ...SURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL PORT BALL VALVE TEMPERATURE GAGE WATER FLOW SWITCH CHECK VALVE WARNING THIS DRAWING SHOWS SUGGESTED PIPING...

Страница 44: ...the Tank Temperature Control COMMERCIAL ELECTRIC 3 UNITS WITH VERTICAL STORAGE TANK LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL...

Страница 45: ...an the Tank Temperature Control COMMERCIAL ELECTRIC 3 UNITS WITH HORIZONTAL STORAGE TANK LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN...

Страница 46: ...RE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL PORT BALL VALVE TEMPERATURE GAGE WATER FLOW SWITCH CHECK VALVE WARNING THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER...

Страница 47: ...ntrol COMMERCIAL ELECTRIC 4 UNITS WITH VERTICAL STORAGE TANK LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL PORT BALL VALVE TEMPERA...

Страница 48: ...Control COMMERCIAL ELECTRIC 4 UNITS WITH HORIZONTAL STORAGE TANK LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL PORT BALL VALVE TE...

Страница 49: ...ze 1 1 2 Table 15 Manifold Kits with Three Heaters Tank Capacity Gallons Part Number H W D A 52 100109232 66 1 4 91 3 4 27 1 4 13 1 4 80 100109232 70 1 2 95 1 4 31 1 4 9 3 4 120 100109232 73 1 4 99 1...

Страница 50: ...50 NOTES...

Страница 51: ...51 NOTES...

Страница 52: ...52 www hotwater com Copyright 2017 A O Smith Corporation All rights reserved...

Отзывы: