Clock/Timer Installation

The Digital Clock/Timer can be mounted to a single or double gang box. To install the Digital Clock/Timer, follow the 
instructions below. Ensure that installation conforms to the National Electrical Code and local wiring codes.

CAUTION: Electric Shock Hazard!

 Ensure that 

NO

 electrical power is present on any wire before installation.

u

  Remove the four sheet metal screws that hold the cover assembly and back plate assembly together. Be sure to  

 

 

keep the sheet metal screw.

v

  Make electrical connections (hot, neutral, ground wires) to non-switched electrical circuit wiring using UL    

 

 

approved wire nuts. Route field wiring away from sharp projections, corners and internal components. for Molex,  

 

 

white to negative/common, black to positive/hot and green to ground. 

w

  Pull the eight wires from the control station through the second bushing of the back plate assembly. The 120vac  

 

 

wires and control station wires should not be run through the same bushing. 

x

  Join the two Molex connectors together, placing excess wiring and Molex connectors into the gang box. 

y

  Mount the back plate assembly to the single or double gang box.

z

  Connect field wiring interconnecting the Clock/Timer with the ATSTCS Control Station to the appropriate  

 

 

 

terminals of the Digital Clock/Timer See wiring detail on next page.

Chassis ground 

MUST

 be connected to conduit/Earth ground to provide proper protection from electric shock.

CAUTION: Electric Shock Hazard!

 When making installation, route field wiring away from sharp projections, corners, and 

internal components. 

 

  Re-attach the cover assembly to the back plate assembly using the sheet metal screws removed in step 1.

  Apply power to the circuit and confirm correct operation.

Installation Schematic

Содержание DSY261RSAE

Страница 1: ...Installation and Operation Manual Part H004423 Rev 5 October 2011 DSY261RSAE Digital Clock Elapsed Time Indicator with Code Blue...

Страница 2: ...ade with energized parts Electrostatic Sensitive Devices CAUTION This equipment contains electronic devices that are sensitive to static electric charges To guarantee protection for the circuitry of t...

Страница 3: ...Setting Time 10 Setting the Up Counter Preset Time 10 Up Counter Elapsed Time Operation 11 Setting the Down Counter Preset Time 11 Down Counter Elapsed Time Operation 11 Free Running Clock Operation 1...

Страница 4: ...nformation regarding the Manufacturer s warranty contact the Original Purchaser OWNER S MANUAL The owner s manual does not purport to cover all the details or variations in the equipment described nor...

Страница 5: ...with 22 AWG stranded wire with minimum 1 32 thick insulation Clock Circuits 3 0mA max 24vac 120vac Code Blue Circuits 3 0mA max 12vac vdc 30vac vdc ENVIRONMENTAL Ambient Operating Range 10 C to 49 C...

Страница 6: ...Control Station the DSY261RSAE can also be used as an up or down counting elapsed timer The elapsed timers can be started stopped resumed and reset Both timer modes have a programmable preset value Wh...

Страница 7: ...rmit Clock Timer to operate Up Clock Down Switch Up Position This position is used to choose up counting elapsed timer mode Clock Position This position is used to choose clock mode Down Position This...

Страница 8: ...ite to negative common black to positive hot and green to ground w Pull the eight wires from the control station through the second bushing of the back plate assembly The 120vac wires and control stat...

Страница 9: ...ower is present on any wire before installation u Pull interconnecting field wires into the double gang box v Connect field wiring interconnecting the ATSTCS Control Station with the Digital Clock Tim...

Страница 10: ...lashing Press the INCREMENT switch until the until the desired minutes are shown and then press ENTER Press the INCREMENT switch again to set the desired seconds and then press ENTER The display will...

Страница 11: ...osition v Set the SET RUN switch to the SET position The hours digits will be flashing w Using the INCREMENT switch set the desired hours for the preset time then press ENTER The minutes digits will n...

Страница 12: ...s system since the 12 hour corrections cannot distinguish AM and PM Setting the Secondary Clock Mode Switch A small rotary switch on the Digital Clock Timer circuit board is used to select the seconda...

Страница 13: ...viewing by pressing the START STOP button on the ATSTCS switch panel The Code Blue timer cannot be restarted from the switch panel To reset the clock back to normal operation the RUN SET switch must...

Страница 14: ...terminals initiates a Code Blue If the Code Blue contact opens and closes again before the Digital Clock Timer is reset back to normal operation the Code Blue timer will start over from 00 00 00 If a...

Страница 15: ...omenon is called memory effect The Ni Cad battery s memory can be erased by deeply discharging the battery and recharging it It is recommended that the operator remove 120vac power from the Digital Cl...

Страница 16: ...y Clock Operation For use with 3 Wire Clocks Appendix 1 START STOP RESET INCREMENT ENTER RUN SET UP DOWN CLOCK K1 Common Clock Timer 120v Run Voltage 120vac 35mA Correct Digital Clock Timer Clock Powe...

Страница 17: ...Clocks Appendix 2 START STOP RESET INCREMENT ENTER RUN SET UP DOWN CLOCK K1 Correct Common Clock Timer 120v Run Voltage 120vac 35mA Correct Digital Clock Timer From Previous Clock or Master Clock Run...

Страница 18: ...cannot be changed and the alarm will not sound Appendix 4 Using the Digital Clock Timer as a Count Down Elapsed Timer Only For applications where the user does not want to use the clock and up count f...

Страница 19: ...REMENT to change Push ENTER Clock displays flashing minutes digits Push INCREMENT to change Push ENTER Clock displays flashing seconds digits Push INCREMENT to change Push ENTER Display shows DONE Pla...

Отзывы: