American Standart Reliant 3 TU385500 Скачать руководство пользователя страница 1

- 1 -

Product names listed herein are trademarks of AS America, Inc.
© AS America, Inc. 2018

 

Thank you for selecting American Standard...
the benchmark of fine quality for over 140 years.

RECOMMENDED TOOLS

M965937 Rev. 1.0 (12/18)

ROUGHING-IN DIMENSIONS

Reliant 3

®

Pressure Balancing Bath  

and Shower Trim Kit

INSTALLATION

INSTRUCTIONS

TU385500

TU385500WD

TU385501

TU385501XH

TU385501WDXH

TU385502

TU385502WD

TU385502WDXH

Plumbers’ Putty

or Caulking

Adjustable Wrench

Channel Locks

Phillips Screwdriver

•  To assure proper positioning in relation to wall. 

Note roughing-in dimensions.

Teflon Tape

Flat Blade Screwdriver

CARTRIDGE INSTALLATION

1

1

1

2

6

5

3

4

UP

UP

H

C

Off

H

C

OFF

18" OPTIONAL

(457 mm)

FINISHED WALL

4"

TOP OF TUB RIM

BOTTOM OF TUB 

74" FOR HEAD

CLEARANCE

4-1/4" REF.

(108 mm)

5-1/2" REF.

(140 mm)

1/2" (13 mm) NPT

1/2" COPPER

7-1/2" DIA.

(191 mm)

1-1/2" REF.

(38 mm)

6" REF.

(152 mm)

3/4"" TO 2-3/8"

(19 TO 60 mm) 

OPTIONAL TO FINISHED

FLOOR USUALLY

BETWEEN 65'' AND 80''

(1651 and 2032 mm)

2-3/4" MAX. (69 mm) 

1-3/4" MIN. (45 mm) 

4-1/2"

(115 mm)

To ensure that your installation proceeds  

smoothly-please read these instructions  

carefully before you begin.

For use with shower heads rated at 4.9 L/min (1.3 gpm) or higher.

•   Remove  PLASTER GUARD

 (6)

 

(Keep it installed for thin wall Installation).

•   Remove BONNET NUT

 (1) 

by unthreading it 

Counter clockwise. Remove test CAP

 (2)

.

•   Remove PROTECTIVE HOUSING

 (3) 

from  

CARTRIDGE

 (4)

. Install with “UP” text on top.

•  Reinstall BONNET NUT 

(1) 

onto VALVE BODY 

(5)  

and tighten firmly with 12 Nm or 9 lbs/ft.

NOTE: 

 Specified tightening torque 

of BONNET NUT

 (1)

 is critical to 

assure sealing function.

Содержание Reliant 3 TU385500

Страница 1: ... mm FINISHED WALL 4 TOP OF TUB RIM BOTTOM OF TUB 74 FOR HEAD CLEARANCE 4 1 4 REF 108 mm 5 1 2 REF 140 mm 1 2 13 mm NPT 1 2 COPPER 7 1 2 DIA 191 mm 1 1 2 REF 38 mm 6 REF 152 mm 3 4 TO 2 3 8 19 TO 60 mm OPTIONAL TO FINISHED FLOOR USUALLY BETWEEN 65 AND 80 1651 and 2032 mm 2 3 4 MAX 69 mm 1 3 4 MIN 45 mm 4 1 2 115 mm To ensure that your installation proceeds smoothly please read these instructions ca...

Страница 2: ...ening SET SCREW 10 from below with 2 5mm Hex Wrench supplied Insert INDEX BUTTON 11 Remove cap from tub supply and plug from shower pipe Install SHOWER ARM 4 and FLANGE 13 ª Tighten SET SCREW 12 onto FLANGE 13 using 5 64 hex wrench Install SHOWER HEAD 5 onto SHOWER ARM 4 Install DIVERTER SPOUT 6 Figure 1 Remove plaster guard from valve Push CAP 1 over VALVE CARTRIDGE 2 until seated against stop Fi...

Страница 3: ... 2 3 4 5 6 7 8 9 10 3 4 1 5 2 VALVE LEAKS WHEN SHUT OFF Remove CARTRIDGE see STEP 1 and STEP 2 and REVERSE process Clean SEALS on the side of CARTRIDGE Clean inside sealing surface of VALVE BODY Re assemble CARTRIDGE Install trim Turn on water supply and check for leaks REPLACING CARTRIDGE To remove CARTRIDGE 1 install split WASHER 3 between the ridge on the cartridge and the bonnet nut only suppl...

Страница 4: ...e POLISHED CHROME 002 BRUSHED NICKEL 295 078016 YYY0A ESCUTCHEON SCREWS M970410 0070A CARTRIDGE M970221 0070A BUTTON SCREW KIT 060351 YYY0A SHOWER ARM AND FLANGE M953579 YYY0A SHOWER HEAD 2 5 GPM M962490 YYY0A ESCUTCHEON AND SCREWS M907050 YYY0A ESCUTCHEON CAP SET M950231 YYY0A DIVERTER SPOUT SLIP ON M970487 YYY0A HANDLE KIT M970457 0070A HANDLE ADAPTER KIT M954805 YYY0A DEEP ROUGH IN KIT M909338 ...

Отзывы: