753027-100 REV. E

(2)

UNLESS AN ACCESS OPENING OF
AT LEAST 12" X 24" (305 X 610MM)
IS PROVIDED, WARRANTY SERVICE
WILL NOT BE PERFORMED.

LEVELING
SURFACE

WATERPROOF
 SEALANT

BATH

TYPICAL PIER TYPE INSTALLATION

A S   D E S I R E D

1022mm

(40-1/4)

AS

DESIRED

1778mm

(70)

CUTOUT

508mm

(20)

ACCESS PANEL

610mm

(24)

305mm

(12)

INSTALLATION AND FRAMING INSTRUCTIONS

The variety of installations possible for this whirlpool may require framing procedures other than those shown.  Locate studs 
as required.  Ensure roughing-in dimensions are proper, plumb and square.  Provisions must be made in all installations for an 
access opening for servicing the pump and controls.  It is strongly recommended that an additional opening be provided for 
access to the drain components.

1. Position the whirlpool into the installation opening and level the deck, shimming the integral support feet as necessary. 

2. Install drain components to the whirlpool following the manufacturers instructions.  Before replacing your whirlpool for final 

installation, be certain that an opening has been provided in the sub-floor for the drain.  See the roughing-in drawing for 
suggested opening size and location dimensions.

3. Replace whirlpool and re-shim the integral support feet, shimming the entire length of the support feet.  Secure the shims 

using construction adhesive, silicone, mortar or equivalent materials.  While not a necessity, the use of a foundation base 
consisting of cement (e.g. Sakrete), mortar, or grout will help provide a solid and secure installation.

Содержание Town Square 2742.XXXW Series

Страница 1: ... for leaks Do not make modifications to the whirlpool system or remove pump from factory mounting This could adversely affect the safety and performance of the whirlpool and void the warranty Do not handle or move the whirlpool by the pump motor or piping system Fittings bath filler shower arm etc are not provided with the bath and must be ordered separately Framing and enclosing materials are pro...

Страница 2: ... recommended that an additional opening be provided for access to the drain components 1 Position the whirlpool into the installation opening and level the deck shimming the integral support feet as necessary 2 Install drain components to the whirlpool following the manufacturers instructions Before replacing your whirlpool for final installation be certain that an opening has been provided in the...

Страница 3: ...RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground fault circuit interrupter 2 Grounding is required The unit should be installed by a licensed electrician and grounded 3 Install to permit access for servicing 4 All building materials and wiring should be routed away from the pump body and heater if equipped The air massage version should be installed on a 120 vac 15 amp dedica...

Страница 4: ... adhesives and or wet oil base paint FEATURES of YOUR NEW AMERICAN STANDARD ACRYLIC BATHTUB Your new acrylic bathtub has been molded in the newest plumbing fixture material available today Acrylics are tough durable finishes that are simple and easy to care for The colors have been formulated to match other American Standard fixtures and enhance your choice of bathroom decorations The high gloss s...

Отзывы: