background image

J36

BARRIER FREE

© 2008 AS America Inc.

489mm

(19-1/4)

543mm

(21-3/8)

184mm

(7-1/4)

73mm

(2-7/8)

203mm

(8)

OPTIONAL

FINISHED

FLOOR

1-1/4 O.D.

TAILPIECE

1-1/4 O.D.

WASTE

203mm

(8)

178mm

(7)

11mm

(7/16)

273mm

(10-3/4)

*

182mm

(7-3/16)

SUPPLIES

AS REQ'D.

COUNTERTOP  (BY OTHERS)

SEALING

COMPOUND

FINISHED

WALL

OR 

SPLASH BACK

327mm

(12-7/8)

*

787mm (31)

851mm (33-1/2)

851mm

(33-1/2)

51mm

(2)

610mm

(24)

152mm

(6)

MAX.

BARRIER FREE

CLEARANCE

686mm

(27)

MIN.

203mm

(8)

MIN.

229mm

(9)

MIN.

DRAWING FOR 

DIMENSIONAL 

PURPOSES ONLY. 

IT IS NOT AN EXACT 

REPRESENTATION.

HEXALYN™

COUNTERTOP SINK

VITREOUS CHINA

HEXALYN™ COUNTERTOP SINK

•  Made from vitreous china
•  Self-rimming with cutout template supplied
•  Front overflow
•  Faucet ledge 
    Shown with 4801.862 Amarilis/Heritage faucet      
    with Triune handles (not included)

 

0485.013

 Faucet holes on 8" (203mm) centers 

 

(Illustrated) 

 

0485.027

 Faucet holes on 4" (102mm) centers

 

0485.033

 Center hole only

 

Nominal Dimensions: 

 

543 x 489mm
(21-3/8" x 19-1/4")

Bowl sizes:

432mm (17") wide
305mm (12") front to back
152mm (6") deep

Compliance Certifications -
Meets or Exceeds the 
Following Specifications:

• ASME A112.19.2M for 
  Vitreous China Fixtures

To Be Specified:

  Color: 

  White   

  Bone 

               

  Linen   

  Silver   

                

  Fawn Beige    

  Black

  Faucet*:

  Faucet Finish:

❏ 

Supplies:

  1-1/4" Trap:

* See faucet section for additional models available

MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES
AND ANSI A117.1  ACCESSIBLE AND USABLE
BUILDINGS AND FACILITIES - CHECK LOCAL CODES.

Install lavatory 864mm (34") from finished floor.
Lavatory installed 51mm (2") minimum from front edge
of countertop provides 686mm (27") knee clearance area.  

NOTES:

*

 DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES AND “P" TRAP ARE 

SUGGESTED

FITTINGS NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED 

SEPARATELY.

FOR COUNTERTOP CUTOUT AND INSTALLATION INSTRUCTIONS USE 

TEMPLATE SUPPLIED WITH SINK.

SEALING COMPOUND SUPPLIED BY OTHERS.

IMPORTANT:

  Dimensions of fixtures are nominal and may vary within the range 

of tolerances established by ANSI Standard A112.19.2.

These measurements are subject to change or cancellation. No responsibility is 

assumed for use of superseded or voided pages.

Revised 2/08