INSTALLATION INSTRUCTIONS

T H A N K     Y O U . . .

for selecting an American Standard bath. Your new bath is shipped to 
you after careful inspection. the whirlpool version is completely 
assembled with pump, motor, and system piping. All you need to finish 
the installation are your selected fittings and electrical connections for 
a whirlpool. To insure maximum performance and pleasure from this 

product, please follow the instructions and cautions. 

General Installation Information

Carefully uncrate and inspect your new bath for any shipping damage. 
If such damage is found, report it to your vendor immediately. After 
inspection and during installation, protect the bath from construction 
damage. Before installation, and before enclosing with wallboard, 
tile, etc., water test the unit and check for leaks. 
Do not make 
modifications to the whirlpool system or remove pump from factory 
mounting. This could adversely affect the safety and performance of 
the whirlpool and void the warranty. Do not handle or move the 
whirlpool by the pump, motor, or piping system. Fittings (bath filler, 
shower arm, etc.) are not provided with the bath and must be ordered 
separately. Framing and enclosing materials are provided by others. 

753456-100 REV. A

© American Standard Inc. 2003
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.

INTEGRAL APRON WITH
REMOVABLE ACCESS PANEL
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS   

HAMPTON 5' x 32"™ 

2425.XXXW-LHO
2425.XXXW-RHO WHIRLPOOL

FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.

General Installation Information

Bath may only be installed in a recess type installation.

Locate studs as required. insure rough dimensions are proper, plumb and square. For whirlpools, access to pump/motor may be made 
through access opening in apron panel. 
The following procedure must be used for all installations: leveling support stringer should be as 
indicated.  this bath is not self-supporting and must be supported along it's entire bottom. Support with mortar or grout. Position 
bathtub/whirlpool within the recess, check level, front to back, side to side, and shim as necessary. To secure the tub to wood studs use 
drywall screws w/washers or roofing nails immediately above the flange of the tub.To secure the tub to steel studs use 4" drywall screws and 
flatwashers.
See page 2 for complete installation information.

Caution: Take extra care when driving nails or screws to avoid damaging the tub. The tile or similar finished floor will be butted against 
the bottom of the tub apron, also holding the tub in place.

IMPORTANT: Water test unit before installation and 
enclosure!

List of Optional Components (not included):
•  Safe-T-Heater 9075.120*

List of Required Components (not included):
•  Drain 1583.470*              •  Bath Filler* 

* see your American Standard Dealer

List of Required Tools and Supplies:

Tools
•  Level
•  Tape Measure
•  Pipe Wrench
•  Slip Joint Pliers
•  Screw Driver
•  Standard
      Woodworking Tools
•  Personal Safety
      Equipment
•  Caulking Gun

Supplies
•  Nails
•  Putty
•  Caulking (waterproof)
•  1 x 3 or 2 x 2
      Stringers
•  Drop Cloth
•  15 amp GFI
      Outlet
•  Cement, Plaster,
      Grout

Left-hand version shown

GENERAL SPECIFICATIONS FOR 2425 WHIRLPOOL

WHIRLPOOL ELECTRICAL SPECIFICATIONS

PUMP

1.6 HP, 9.7 AMPS,120V.

60 x 32 x 21-1/2 (1524 x 813 x 546mm)

115 Lbs. (52 Kg.)

574 Lbs. (258 Kg.)

55 Gal. (208 L.)

  45 Gal. (171 L.)

16-1/4 x 38-1/4 (413 x 972mm)

26-1/4 x 52-1/2 (667 x 1334mm)

15 (381mm)

 43 Lbs./Sq.Ft. (208 Kgs./Sq.m)

20.8
35.3

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT

3

)

21-1/4

(540mm)

REF.

DIM

1" WATER

RETENTION

FLANGE

(3 SIDES)

21-1/2

(546mm)

1-1/2 O.D.TAILPIECE

BATH

SUPPORT

MATERIAL

LEVELING STRINGER
NOT FOR SUPPORT 

ROUGH

FLOOR

FINISHED

WALL

TOP OF

DECK

60

(1524mm)

32

(813mm)

WATER
RETENTION
FLANGE
(3 SIDES)

10-1/4

(260mm)

12

(305mm)

3

(76mm)

(8) JETS

3-1/2

(89mm)

CUTOUT IN FLOOR FOR DRAIN

PUMP

FINISHED

WALL

12

(305mm)

OPT.

OPTIONAL TO 

FINISHED FLOOR 

USUALLY BETWEEN

65 & 78

(1651 & 1981mm)

C/L OF
OVERFLOW

4

(102 mm)

C/L OF
SPOUT

TILING
FLANGE

C/L OF
VALVES

C/L OF
SHOWER ARM

2-3/4

(70mm)

 4-5/8

(117mm)

1-1/2 N.P.T.M.

THREADS

3/4

(19mm)

9

(229 mm)

C/L OF

SUPPLIES

C/L OF DRAIN

SEE FITTING

SPECS FOR

DIMENSIONS

(2) AIR VALVES

ON/OFF
SWITCH

ACCESS TO PUMP/MOTOR
THROUGH REMOVABLE
FRONT ACCESS PANEL

UNDERSIDE
OF DECK

16

(406mm)

SAFE-T-HEATER
REMOVABLE
BLANK

Отзывы: